Calder Industrial Code 4 Lead Flashing - 450mm x 6000mm
Lead roof flashing provides a long-term watertight roofing option and lasts three times longer tha...Lead roof flashing provides a long-term watertight roofing option and lasts three times longer than most man-made alternatives. Lead is one of the most environmentally-friendly materials used in the construction industry. The initial installation cost of lead is comparable to man-made flashings when the additional expense of adhesives and sealants are taken into account. Lead is quick and easy to install in most weather conditions and requires no adhesive or other fixing materials. Alternatives are very limited in the types of applications that they can be used for, and would not be suitable for more decorative flashings for which lead is renowned. When bossed or dressed correctly lead has few laps or joints resulting in a high degree of weather tightness. Lead lasts up to 100 years and when used for flashings will last three times longer than most man-made products. There is little post-installation inspection or maintenance required. All lead sheet should be coated with patination oil after installation. Guides to cover flashing and step flashing are available at http://www.calderlead.co.uk/downloads/ or use the link at http://youtu.be/eS4CfS-K0PE and http://youtu.be/GBtvHif6bTE. Please refer to the Calder Training Module Ask a Question for a quick guide to selling lead. Code 4 Roofing Lead Flashing Roll from Calder is for the protection of roofs against water penetration. Flexible, easily shaped and long-lasting while enduring all weather conditions, it is perfectly suited to the climate in the UK. Suitable for sealing gaps around doors and windows. Manufactured from continuously recyclable material.
This guide is for homeowners and contractors using Calder Code 4 Lead Flashing. It provides a comprehensive overview of the product's features, benefits, and how to use it effectively. The lead flashing offers superior, long-lasting watertight protection for roofs. However, proper installation is crucial for optimal performance.
All features
Model Part Number
40022445
Brand
Calder
Extended Product Information
FAQs
How long does Calder Code 4 Lead Flashing last?
When installed correctly, it can last up to 100 years.
Is lead flashing environmentally friendly?
Yes, lead is one of the most environmentally friendly materials used in the construction industry, and it is continuously recyclable.
Does the flashing require any special tools for installation?
Standard roofing tools are needed, such as a lead dresser and appropriate fixings.
Can I use lead flashing around any type of roof?
It is compatible with most roofing materials, but always check for compatibility before installation.
Does lead flashing require maintenance?
Little post-installation inspection or maintenance is required. However, it is advisable to check periodically for any damage or movement.
Where can I find installation guides?
Guides are available at http://www.calderlead.co.uk/downloads/ or use the links at http://youtu.be/eS4CfS-K0PE and http://youtu.be/GBtvHif6bTE.
What is Code 4 lead flashing?
Code 4 refers to the thickness of the lead sheet. Code 4 is a common thickness used for roofing applications, providing a balance of durability and flexibility.
Troubleshooting
Water Leaks
Inspect the flashing for any gaps, tears, or improper seals. Re-seal or replace damaged sections. Ensure correct overlaps.
Flashing is not staying in place.
Check the fixings to ensure they are secure. Replace any loose or damaged fixings.
Discoloration or surface issues
Apply patination oil as directed to protect the lead from the elements and maintain its appearance.
Pros and Cons
Pros
Durable and long-lasting, providing decades of protection.
Environmentally friendly compared to many alternatives.
Easy to install with no need for adhesives or sealants.
Highly flexible and can be shaped to suit different roof designs.
Requires minimal post-installation maintenance.
Cost-effective when considering its lifespan and performance.
Cons
Requires proper installation techniques to ensure watertight seals.
Can be more expensive upfront compared to some man-made alternatives.
Lead sheet should be coated with patination oil after installation.
Not suitable for all flashing applications.
Requires professional expertise for complex installations.
Setup, Compatibility & Care
Preparation: Ensure the surface is clean, dry, and free of debris. Measure and cut the lead flashing to the required size.
Installation: Position the lead flashing correctly. For step flashing, overlap the lead sheets. Follow manufacturer's instructions for specific applications.
Fixing: Secure the flashing using appropriate fixings (e.g., lead tacks) where necessary. Ensure fixings are properly sealed.
Sealing: Use patination oil after installation.
Compatibility: Calder Code 4 Lead Flashing is compatible with most roofing materials. Always check for compatibility with specific materials before installation.
Care: Minimal maintenance is required. Periodically inspect the flashing for any damage or movement. Clean the flashing with a soft brush and water if needed.