Calder Industrial Code 5 Lead Flashing - 450mm x 6m

Lead roof flashing provides a long-term watertight roofing option and lasts three times longer tha...

Best current price£360.18from Travis Perkins

One Offer

1 offer from £360.18

View price history by clicking the chart icon.

Travis PerkinsCalder Industrial Code 5 Lead Flashing 450mm x 6000mm
Free delivery in 1–3 days
£360.18
Visit shop

Product Information

Full details

This guide is for roofing professionals and DIY enthusiasts seeking a durable, long-lasting, and environmentally friendly solution for roof waterproofing. The Calder Industrial Code 5 Lead Flashing offers superior weather tightness and a lifespan up to 100 years, significantly outperforming man-made alternatives. While its initial installation cost is comparable to other materials when accounting for sealants, it requires minimal post-installation maintenance. Key features include its flexibility, ease of installation in various weather conditions, and suitability for decorative applications.

All features

Model Part Number40022545
BrandCalder

Extended Product Information

FAQs

What is Code 5 Lead Flashing?

Code 5 refers to the thickness of the lead sheet, with Code 5 being a common standard for roofing applications, balancing flexibility and durability.

How long does lead flashing typically last?

Calder lead flashing is designed to last up to 100 years, which is significantly longer than most man-made alternatives, often three times as long.

Is lead flashing environmentally friendly?

Yes, lead sheet is produced from 100% recycled lead, and the recycling process has a low carbon footprint and requires less energy compared to primary material production.

Do I need special tools to install lead flashing?

Basic roofing tools are typically sufficient. Specific tools for dressing and bossing lead may be beneficial for achieving a professional finish. No adhesives or special fixing materials are usually required.

What is patination oil and why is it important?

Patination oil is applied after installation to protect the lead from forming white oxide, which can appear unsightly and potentially compromise the surface over time. It helps maintain the lead's appearance and protective qualities.

Can lead flashing be used for decorative purposes?

Yes, lead is renowned for its suitability for decorative flashings when bossed or dressed correctly, offering aesthetic possibilities not easily achieved with other materials.

What is the difference between lead flashing and alternatives?

Lead flashing offers superior longevity, flexibility, and easier installation in varied weather without adhesives. Alternatives often have limited applications and may not match lead's lifespan or aesthetic potential.

Troubleshooting

White powdery substance forming on lead surface

This is likely white oxide. Ensure patination oil was applied correctly after installation. Reapply patination oil as per manufacturer instructions.

Lead flashing not sitting flush or is difficult to shape

Ensure the lead has been adequately softened (if applicable by temperature) and is being dressed correctly. Use appropriate tools and techniques for shaping. Review installation guides for proper dressing methods.

Water pooling around the flashing area

Check for blockages in adjacent gutters or drainage paths. Inspect the flashing for any damage, gaps, or improper installation. Ensure the lead is correctly integrated with the roofing system to direct water away.

Pros and Cons

Pros

  • Exceptional longevity, lasting up to 100 years.
  • Environmentally sustainable due to recycled material and low energy production.
  • Quick and easy installation process, often without additional materials.
  • High degree of weather tightness when properly installed.
  • Suitable for both functional and decorative roofing elements.
  • Low maintenance requirements after installation.

Cons

  • Requires specific handling and knowledge for optimal installation.
  • Lead sheet can be a target for theft due to its material value.
  • Needs to be coated with patination oil after installation for protection.
  • While environmentally friendly in production, lead is a heavy metal with environmental considerations if improperly disposed of.

Setup, Compatibility & Care

Setup:

  1. Ensure the surface area is clean and dry before application.
  2. Cut the lead sheet to the required size and shape using appropriate tools.
  3. Dress and boss the lead carefully to conform to the roof contours, minimizing laps and joints.
  4. Secure the lead in accordance with best roofing practices, often requiring no additional adhesives or fixings for standard applications.
  5. For detailed installation guidance on cover flashing and step flashing, refer to resources at http://www.calderlead.co.uk/downloads/ or the video guides at http://youtu.be/eS4CfS-K0PE and http://youtu.be/GBtvHif6bTE.

Compatibility:

Calder Industrial Code 5 Lead Flashing is compatible with most common roofing materials, including tiles, slate, and bitumen. It is designed for use in conjunction with traditional roofing systems.

Care:

  • Patination Oil: After installation, all lead sheet must be coated with patination oil to prevent the formation of white oxide. This is a critical step for protecting the lead and ensuring its longevity.
  • Cleaning: Generally, lead flashings require very little cleaning. If significant debris accumulates, it can be gently brushed away. Avoid abrasive cleaners.
  • Inspection: Periodic visual inspection is recommended, although maintenance is minimal.

Price History

DatePrice
Visit shop