Regulates sealed heating system differential pressure. Features a 22mm compression fitting and loc...Regulates sealed heating system differential pressure. Features a 22mm compression fitting and lockable set pressure. This valve regulates flow through the boiler and reduces system noise. It is a brand new, genuine original Tower 22mm automatic bypass valve, for installation in systems where a boiler bypass is required, typically when a system is equipped with thermostatic radiator valves (TRVs), and to allow pump overrun operation after zone valves have closed down. When correctly set, this valve will regulate system pressure, thereby reducing system noise, pump impeller wear and enhance boiler heat exchanger life by ensuring minimum flow rate at all times. Specifications: High capacity flow up to 50 litres per minute. Differential pressure range 0.1 to 0.6 bar. Reduces system noise.
22mm Auto Bypass Valve TOWER Boiler Pressure ABV Automatic Radiator 50L 3m3/hrFree delivery in 1–3 days£15.99Visit shop →
Product Information
Full details
This guide is for homeowners and HVAC professionals using the Tower Auto Bypass Valve - 22mm. It helps maintain optimal pressure in sealed heating systems, reducing noise and extending the lifespan of your boiler. However, it's essential to understand the correct pressure settings for your specific system.
All features
Model Part Number
ABBV1
Brand
Tower
Extended Product Information
FAQs
What is the purpose of the Tower Auto Bypass Valve?
It regulates flow through the boiler and reduces system noise by maintaining a minimum flow rate, especially when TRVs are installed.
What size pipework does this valve fit?
This valve fits 22mm pipework.
How do I set the pressure on the valve?
You will need to use a pressure gauge to set the valve within the specified pressure range for your boiler. Consult your boiler manual or a professional.
Where should the bypass valve be installed?
The valve is typically installed between the flow and return pipes of the heating system, after the pump and before the boiler.
How do I know if the valve is working?
You can monitor the system pressure. When TRVs close, the valve should open, maintaining a consistent pressure.
Can I install this valve myself?
If you are comfortable with plumbing, yes, but professional installation is recommended. Always ensure the system is depressurized before beginning any work.
What should I do if the valve leaks?
Turn off the heating system and consult a qualified plumber or HVAC technician.
Troubleshooting
System noise persists after installation.
Check the pressure setting. It may need adjustment. Also, ensure all TRVs are functioning correctly. If the noise continues, consult a qualified HVAC technician.
Boiler overheating or shutting down.
The bypass valve may not be opening correctly. Check for blockages in the valve or associated pipework. Ensure the valve is installed correctly and that the pressure is set appropriately.
Pros and Cons
Pros
Reduces system noise, leading to a quieter home environment.
Extends the lifespan of your boiler's heat exchanger by ensuring minimum flow rates.
Easy to install with the 22mm compression fitting.
Helps to prevent pump impeller wear and tear.
Lockable pressure setting for secure and reliable performance.
Cons
Requires proper setting of differential pressure for optimal performance.
May require professional installation for those unfamiliar with plumbing systems.
Does not address issues other than pressure regulation.
Does not solve the root cause of some heating system problems.
Setup, Compatibility & Care
Installation: The valve is designed for easy installation with a 22mm compression fitting. Ensure the system is drained and depressurized before installation. Follow the manufacturer's instructions carefully.
Compatibility: Compatible with most sealed heating systems. Ensure your system's specifications align with the valve's differential pressure range (0.1 to 0.6 bar) and flow capacity.
Pressure Setting: Set the pressure according to your boiler's specifications. Consult your boiler manual or a qualified HVAC technician for guidance. Incorrect pressure settings can lead to inefficiency or damage.
Maintenance: Regularly inspect the valve for leaks or unusual noises. No specific maintenance is required, but an annual system checkup by a qualified technician is recommended.