Climaflex Polyethylene Pipe Insulation - Bore 15mm - Wall 25mm - Length 2m

A flexible pipe insulation manufactured by extrusion of expanded polyethylene material. This produ...

Best current price£9.62from Travis Perkins

One Offer

1 offer from £9.62

View price history by clicking the chart icon.

Travis PerkinsClimaflex Polyethylene Pipe Insulation Bore 15mm Wall 25mm Length 2m
£30.00 delivery
£9.62
Visit shop

Product Information

Full details

This guide is for plumbers, contractors, and DIY enthusiasts seeking effective thermal and acoustic insulation for pipes. The Climaflex Polyethylene Pipe Insulation provides excellent thermal performance and environmental safety, making it a reliable choice for a variety of applications. A key consideration is ensuring the correct bore and wall thickness are selected for optimal fit and function.

All features

Model Part Number794856
BrandClimaflex

Extended Product Information

FAQs

What does 'Bore 15mm - Wall 25mm' mean?

The 'Bore 15mm' refers to the internal diameter of the insulation sleeve, designed to fit pipes with a nominal diameter of 15mm. The 'Wall 25mm' refers to the thickness of the polyethylene material, indicating the level of thermal insulation provided.

Is this product suitable for outdoor use?

While the material offers good durability, prolonged exposure to direct sunlight (UV radiation) can degrade polyethylene over time. For outdoor applications, consider additional protective jacketing or coatings.

What is the thermal conductivity of this insulation?

The thermal conductivity varies with temperature: 0.034 W/mK at 0°C, 0.036 W/mK at 20°C, and 0.039 W/mK at 40°C, according to DIN 52613.

Can I use this insulation on heating pipes?

Yes, it is suitable for insulating hot water heating pipes to reduce heat loss. Ensure the operating temperature of the pipe does not exceed the product's recommended maximum service temperature.

How do I cut the insulation to size?

A sharp utility knife or a specialized insulation cutter works best for a clean cut. Ensure the blade is sharp to avoid tearing the material.

What does Class P fire rating mean?

A Class P fire rating generally indicates that the material has been tested and meets specific standards for fire performance, often relating to its contribution to fire spread. Further details can be found in the specific product documentation or relevant British Standards.

Troubleshooting

Difficulty sliding insulation onto pipe

Ensure the correct bore size has been selected. If tight, a small amount of water or mild soap solution can aid installation, but allow it to dry fully before sealing.

Gaps at joints or seams

Ensure insulation is cut to the correct length and that all joints are properly sealed with suitable insulation tape or adhesive to prevent thermal bridging and moisture entry.

Condensation forming on insulation exterior

This often indicates a breach in the insulation seal, allowing moist air to reach the cold surface. Check and re-seal all joints and seams meticulously.

Insulation appears to be degrading

Check for exposure to UV light or incompatible chemicals. Ensure the product is used within its intended temperature range. Replace damaged sections.

Pros and Cons

Pros

  • Excellent thermal insulation properties, leading to energy efficiency.
  • Environmentally friendly with no CFCs or HCFCs.
  • Meets stringent British Standards (BSI approved).
  • Durable and flexible material for easy handling and installation.
  • Good fire performance rating (Class P).

Cons

  • Requires precise measurement for correct bore and wall thickness selection.
  • May not be suitable for extremely high-temperature applications without additional protection.
  • Can be punctured or damaged if not handled with care during installation.
  • Requires appropriate cutting tools for clean installation.

Setup, Compatibility & Care

Setup:

  1. Measure Pipe Diameter: Accurately measure the outer diameter of the pipe you intend to insulate.
  2. Select Correct Insulation: Choose the Climaflex insulation with a bore size that closely matches your pipe diameter (e.g., Bore 15mm for pipes with a nominal diameter of 15mm). The wall thickness (e.g., 25mm) determines the level of insulation.
  3. Cut to Length: Using a sharp knife or specialized insulation cutter, cut the insulation to the required length, allowing for slight overlap at joints if necessary.
  4. Install: Slide the pre-formed insulation sleeve over the pipe. For long runs, multiple sections can be joined.
  5. Secure: Seal all joints and seams using appropriate insulation tape or adhesive to maintain thermal integrity and prevent moisture ingress.

Compatibility:

  • Suitable for use with copper, plastic, and steel pipes.
  • Designed for standard plumbing and HVAC applications.
  • Ensure the ambient and fluid temperatures are within the product's operational limits.

Care:

  • Keep insulation clean and free from dust and debris.
  • Inspect regularly for any signs of damage, such as tears or punctures, and repair immediately.
  • Avoid prolonged exposure to direct sunlight or harsh chemicals which may degrade the material.