Aico EI3028 Multi-Sensor Heat & CO Alarm

This Aico EI3028 Multi-Sensor Heat & CO Alarm contains both a heat and electrochemical carbon mono...

Best current price£52.18from eBay

All Offers

7 offers from £52.18 - £98.77

View price history by clicking the chart icon.

eBayAICO Ei3028 Mains Multi-Sensor Heat & Carbon Monoxide Alarm Exp May 2035
Free delivery in 1–3 days
£52.18
Visit shop
City Plumbing GBAico Ei3028 Multi-Sensor Heat & Co Alarm
Free delivery in 1–3 days
£79.19
Visit shop
Travis PerkinsAico Ei3028 3000 Series Multi-Sensor Heat & Carbon Monoxide Alarm
£20.00 delivery
£94.73
Visit shop
OnBuy.comEi3028 Aico Combined Heat & Carbon Monoxide Detector, Mains Powered - Multi-Sensor Alarm 5099383006544
Free delivery in 1–3 days
£98.77
Visit shop

Product Information

Full details

This guide is for homeowners and professionals seeking comprehensive home safety. The Aico EI3028 provides dual protection against both heat and carbon monoxide threats, offering peace of mind. Note that while it offers robust features, it requires professional installation for mains-powered units.

All features

Model Part NumberEi3028
BrandAico

Extended Product Information

FAQs

How do I test the alarm?

Press the Test/Hush button on the alarm. The alarm should sound.

How do I silence the alarm?

Press the Test/Hush button to silence a false alarm. It will silence the alarm for approximately 10 minutes.

What is the lifespan of the alarm?

The alarm has a 10-year lifespan.

What should I do if the alarm goes off?

If the alarm sounds, immediately evacuate the premises and call the emergency services. For CO alarms, open windows and doors to ventilate the area.

How do I know if the alarm has detected CO?

The alarm head includes an indicator for CO detection, and the AudioLINK+ technology can provide detailed data.

Where should I install the alarm?

Install the alarm in areas where there is a risk of both heat and CO, such as kitchens, living areas, and near fuel-burning appliances. For optimal coverage, install the alarm on the ceiling or high on a wall.

Can I install the alarm myself?

While the alarm can be mounted easily, the mains power connection must be done by a qualified electrician.

What standards does the alarm comply with?

The alarm complies with BS 5446-2: 2003 and BS EN 50291-1: 2010 standards.

Troubleshooting

Alarm is not turning on.

Check the mains power connection and the battery backup. Ensure both are properly connected.

Alarm sounds frequently without any apparent cause.

Check for sources of carbon monoxide (faulty appliances) and potential heat sources. Clean the alarm of dust and debris. If the issue persists, the alarm may be faulty and need replacing.

Wireless interconnection not working.

Ensure the Ei3000MRF module is correctly installed and that the other alarms are properly linked. Refer to the module's manual for pairing instructions.

Pros and Cons

Pros

  • Dual protection against heat and carbon monoxide.
  • Reliable mains power with battery backup.
  • Wireless interconnection capabilities for enhanced safety.
  • Easy-to-understand visual indicators.
  • Long operational lifespan.
  • Complies with relevant safety standards.

Cons

  • Requires professional installation for mains power connection.
  • Additional module needed for wireless interconnection functionality.
  • Data extraction requires the AudioLINK+ app.

Setup, Compatibility & Care

Setup

  1. Professional Installation: This alarm requires a mains power connection, which should be installed by a qualified electrician.
  2. Base Installation: Attach the easy-fit base to the ceiling or wall in the desired location.
  3. Alarm Attachment: Clip the alarm unit onto the base.
  4. Testing: After installation, test the alarm using the Test/Hush button to ensure it functions correctly.

Compatibility

  • This alarm is compatible with other Aico mains powered units.
  • It is designed to work with the Ei3000MRF module for wireless interconnection.

Care

  • Regular Testing: Test the alarm monthly using the Test/Hush button.
  • Cleaning: Clean the alarm with a slightly damp cloth to remove dust and debris. Do not use cleaning agents.
  • Replacement: Replace the alarm after 10 years, as indicated by its lifespan.

Similar items

Price History

DatePrice
Visit shop