The Altecnic Robocal automated air vent is designed for heating and cooling systems to continuousl...The Altecnic Robocal automated air vent is designed for heating and cooling systems to continuously remove air without manual intervention. It releases air upon system water filling and automatically isolates, preventing water loss, reducing noise, and improving the precision of control valves and overall equipment performance. The automatic air vents operate via a float mechanism, designed for air removal from systems, with a discharge pressure of 6 bar. They are small-sized valves suitable for tight installations, with an optional manual cap and available in compression or male threads. Sizes range from 1/4" to 1/2" or 15mm compression, with check valves available. Installers often encounter customer complaints about system noises indicating air presence.
This guide is for anyone using the Altecnic Automatic Air Vent in their heating or cooling system. The primary benefit is continuous air removal, leading to quieter operation and improved system efficiency. A key point to remember is to ensure proper installation to avoid potential leaks. This product, designed by Altecnic, continuously removes air from heating and cooling systems. It features an automatic float mechanism, compact size, and is available in various sizes and thread connections, all contributing to optimized system performance.
All features
Colour
Bronze
Model Part Number
502649
Brand
Altecnic
Extended Product Information
FAQs
How does the automatic air vent work?
It uses a float mechanism to detect air pockets. When air accumulates, the float drops, opening the vent to release the air. When water reaches the vent, the float rises, closing the vent.
What is the recommended installation position?
Install the vent at the highest point in your system where air tends to accumulate.
What are the common thread connections available?
It is available in compression or male threads, depending on the specific model.
Can I use this vent in a domestic water system?
No, this vent is designed specifically for heating and cooling systems, not for potable water.
How often should I inspect the air vent?
It is recommended to inspect the vent during routine system maintenance checks. This will vary depending on your system.
What should I do if the vent is leaking?
Check the connections and ensure they are sealed properly. If the leak continues, the vent might need to be replaced.
Does this vent require any manual adjustment?
No, the Altecnic automatic air vent operates automatically and does not require manual intervention after installation.
What is the discharge pressure of the air vent?
The discharge pressure is 6 bar.
Troubleshooting
System leaks from the vent.
Check the threads and connections for proper sealing. Tighten connections if needed. If the leak persists, consider replacing the vent.
System not venting air.
Ensure the vent is installed at the highest point. Check for any blockages within the vent. Confirm the system pressure is within the vent's operational range.
Noisy operation after installation.
The system may still contain air. Cycle the system and check for leaks. If the noise persists, it could be a sign of another issue within the system.
Pros and Cons
Pros
Reduces system noise caused by air pockets.
Improves the efficiency of heating and cooling systems.
Prevents water loss through automatic isolation.
Compact size facilitates installation in confined areas.
Enhances the precision of control valves and overall equipment performance.
Requires no manual intervention once installed.
Cons
Requires proper installation to prevent leaks.
May require occasional inspection to ensure optimal performance.
Float mechanism can be affected by debris.
Specific thread size must be selected for compatibility.
Requires access for potential maintenance.
Setup, Compatibility & Care
Setup
Preparation: Ensure the system is depressurized and cooled down before installation.
Location: Install the vent at the highest point of the system or at strategic points where air is likely to accumulate.
Connection: Use the appropriate thread size (15mm compression in this case) and ensure a tight, leak-proof seal. Use thread sealant if necessary.
Activation: Once installed, slowly re-pressurize the system. The vent will automatically release trapped air.
Compatibility
System Type: Suitable for use in both heating and cooling systems.
Fluid Compatibility: Compatible with water and glycol solutions commonly used in HVAC systems.
Pressure Rating: Designed for a discharge pressure of 6 bar. Ensure your system operates within this range.
Care
Inspection: Regularly inspect the vent for any signs of leaks or blockages.
Cleaning: If necessary, clean the vent's internal components to remove debris that may affect its operation. Be sure to isolate the system.
Maintenance: While the vent is designed for automatic operation, periodic checks are recommended to ensure optimal performance. Refer to the manufacturer's guidelines for detailed maintenance instructions.