The Catnic CX90 100 Extra-Heavy Duty Catnic Lintel is designed for Cavity Walls with a Built-in Da...The Catnic CX90 100 Extra-Heavy Duty Catnic Lintel is designed for Cavity Walls with a Built-in Damp Proof Course (DPC). It features a duplex anti-corrosion finish, galvanised and powder coated for lifetime resistance in harsh environments. This premium steel lintel offers integral plaster key, continuous insulation for reduced cold bridging, and supports concrete floors, roof loads, and attic truss loads. It is suitable for fair face inner leaf masonry and structural openings from 750 mm up to 4500 mm, spanning cavities from 90 mm to 105 mm with a minimum 150 mm bearing at each end. The Catnic CX90/100 is BBA approved. For lengths from 900 mm up to 2700 mm, it can handle a loading of 60 kN, with longer versions supporting less. The lintel has a drip to aid water shedding. It is an open-back profile lintel, incorporating insulation, built-in plaster key and DPC.
Catnic Timber Frame Steel Lintel Standard Duty 2100mm CTF5Free delivery in 1–3 days£166.34Visit shop →
Catnic Timber Frame Steel Lintel Standard Duty 2250mm CTF5Free delivery in 1–3 days£175.27Visit shop →
Catnic Cougar Open Back Cavity Wall Standard Duty Lintel 900mm CG150/100Free delivery in 1–3 days£190.45Visit shop →
Catnic Timber Frame Steel Lintel Standard Duty 2400mm CTF5Free delivery in 1–3 days£192.26Visit shop →
Product Information
Full details
This guide is for builders and construction professionals using the Catnic CX90/100 Extra-Heavy Duty Lintel. It provides robust support for cavity walls, offering a built-in damp proof course and lasting protection against corrosion. Note that the load-bearing capacity varies with the length of the lintel, so ensure you choose the correct size for your project.
All features
Model Part Number
CG50
Brand
Catnic
Extended Product Information
FAQs
What is the maximum span for the CX90/100?
The maximum span is 4500 mm, but the load-bearing capacity decreases with longer spans.
What cavity widths does this lintel support?
It supports cavities from 90 mm to 105 mm.
Does the lintel have a built-in DPC?
Yes, it has a built-in damp proof course.
What is the minimum bearing required?
A minimum bearing of 150 mm is required at each end.
What is the load capacity for shorter lengths?
For lengths up to 2700mm, it can handle 60 kN.
What materials is the CX90/100 made from?
It is made of steel with a duplex anti-corrosion finish (galvanized and powder coated).
Is the lintel BBA approved?
Yes, the Catnic CX90/100 is BBA approved.
How should I store the lintel before installation?
Store the lintel in a dry place, protected from the elements, and handle it carefully to avoid damaging the protective coating.
Troubleshooting
Lintel appears to be sagging.
Check the load capacity of the installed lintel. It may be overloaded. Ensure correct bearing at each end.
Difficult to install.
Ensure the opening is correctly sized. Check for obstructions. Consider using lifting equipment.
Rust or corrosion is visible.
Check for damage to the protective coating during installation. Replace the lintel if the corrosion is significant.
Pros and Cons
Pros
Durable construction with a duplex anti-corrosion finish.
Provides a built-in DPC, enhancing moisture resistance.
Offers continuous insulation to reduce thermal bridging.
Supports heavy loads from concrete floors, roof structures, and attic trusses.
Designed for a wide range of cavity wall sizes (90 mm to 105 mm).
Easy to install due to the open-back profile.
Cons
Load capacity decreases with increasing lintel length.
Requires careful planning to ensure the correct size for the specific load and span.
May require specialist handling due to its weight.
Specific dimensions must be matched to your cavity and load requirements.
Setup, Compatibility & Care
Preparation: Ensure the opening is correctly sized and prepared to receive the lintel. Check the cavity width.
Installation: Position the lintel with a minimum bearing of 150 mm at each end. Ensure the DPC is correctly aligned.
Support: Provide temporary support during installation. Consider the load the lintel will carry.
Compatibility: Designed for cavity walls. Ensure compatibility with the building's structural design.
Care: Handle with care to avoid damage to the protective coating. Do not cut or modify the lintel.
Maintenance: The anti-corrosion finish requires no maintenance.