Lapp H05V2-K Installation Wire - [100 Meters] - White

Lapp H05V2-K 90° xx installation wire, conductor composition class 5 = flexible, nominal conductor...

Best current price£31.39from Tameson UK

Colour

All Offers

4 offers from £31.39 - £118.75

View price history by clicking the chart icon.

Tameson UKLapp White H05v2-K Installation Wire - 4515051-100 [100 Meters]
Free delivery in 1–3 days
£31.39
Visit shop

Product Information

Full details

The Lapp H05V2-K 90° installation wire is designed for electrical installations requiring flexible conductors with a nominal cross-section of 0.75mm². It is suitable for electricians and DIY enthusiasts working on fixed installations where flexibility and adherence to fire safety standards are crucial. The key benefit is its reliable performance and adherence to CPR Euro fire class eca standards. A caveat to consider is its specific voltage rating of 500V, which must be matched to the application's requirements.

All features

ColourWhite
Model Part Number4515052
BrandLAPP

Extended Product Information

FAQs

What is the primary application for this wire?

This wire is primarily intended for fixed electrical installations in buildings, suitable for lighting, power, and control circuits where flexibility is required.

What does 'H05V2-K' signify?

'H05' indicates a harmonized flexible cable with a 500V rating. 'V2' refers to PVC insulation with increased temperature resistance, and 'K' denotes a flexible conductor class 5.

Can this wire be used for outdoor applications?

This specific wire is designed for indoor fixed installations. For outdoor use, cables with appropriate weather and UV resistance ratings should be selected.

What is the conductor material?

The conductor is made of copper.

What is the nominal voltage rating?

The nominal voltage rating is 500V.

How many conductors are in this wire?

This product is a single-core wire, meaning it contains one conductor.

What does CPR Euro fire class eca mean?

It means the cable meets specific European standards for reaction to fire, classified as 'eca' which is a basic level of fire performance for building materials.

Troubleshooting

Wire is difficult to bend or route

Ensure you are using the correct H05V2-K type, which is designed for flexibility. If severe stiffness is encountered, check for damage to the conductor or insulation. Consider using a slightly larger bend radius.

Connection is loose

Ensure the conductor end is properly stripped and inserted fully into the terminal. Tighten the terminal screw securely but do not overtighten, which could damage the conductor.

Wire insulation appears damaged

Immediately replace any section of wire with damaged insulation. Do not attempt to repair the insulation; use a new, undamaged piece of wire.

Pros and Cons

Pros

  • High flexibility due to Class 5 conductor.
  • Durable PVC insulation for longevity.
  • Clear white color for easy identification.
  • Meets specific fire safety standards (CPR Euro class eca).
  • Suitable for fixed electrical installations.
  • Compact diameter for easier routing.

Cons

  • Limited to 500V nominal voltage, not suitable for higher power applications.
  • Specific fire classification (eca) may not be sufficient for all demanding environments.
  • White color may show dirt more easily in some industrial settings.
  • Only available in a 0.75mm² cross-section, limiting options for different current loads.

Setup, Compatibility & Care

Setup:

  1. Ensure the power supply to the circuit is disconnected and locked off.
  2. Strip the outer PVC insulation carefully, avoiding damage to the conductors.
  3. Strip a small amount of insulation from the conductor ends as required for connection.
  4. Connect the white conductor to the appropriate terminal, ensuring a secure fit.

Compatibility:

  • This wire is designed for fixed installations and is compatible with standard electrical connection terminals and junction boxes.
  • Verify that the 500V nominal voltage rating is suitable for your specific electrical system requirements.
  • Check that the CPR Euro fire class eca rating meets the building codes and safety regulations for your installation location.

Care:

  • Keep the wire clean and free from excessive dust or debris.
  • Avoid exposing the wire to extreme temperatures or chemicals that could degrade the PVC insulation.
  • Periodically inspect connected terminals for tightness, as per standard electrical maintenance practices.

Price History

DatePrice
Visit shop