Lapp H05V2-K Installation Wire - [100 Meters] - White
![Lapp H05V2-K Installation Wire - [100 Meters] - White](https://shopping-cdn.redbrainapis.com/v/72df5294791c7cdc8b93773566069f9f7661f097ef4354167b0ad6c67f1b1a27_500x500.jpeg)
Best current price£31.39from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Lapp White H05v2-K Installation Wire - 4515051-100 [100 Meters]
Visit shop![Lapp H05V2-K Installation Wire - [100 Meters] - White](https://shopping-cdn.redbrainapis.com/v/72df5294791c7cdc8b93773566069f9f7661f097ef4354167b0ad6c67f1b1a27_500x500.jpeg)
Best current price£31.39from Tameson UK
Shopping.co.uk recommended and popular offers
Lapp White H05v2-K Installation Wire - 4515051-100 [100 Meters]
Visit shop4 offers from £31.39 - £118.75
View price history by clicking the chart icon.
The Lapp H05V2-K 90° installation wire is designed for electrical installations requiring flexible conductors with a nominal cross-section of 0.75mm². It is suitable for electricians and DIY enthusiasts working on fixed installations where flexibility and adherence to fire safety standards are crucial. The key benefit is its reliable performance and adherence to CPR Euro fire class eca standards. A caveat to consider is its specific voltage rating of 500V, which must be matched to the application's requirements.
| Colour | White |
|---|---|
| Model Part Number | 4515052 |
| Brand | LAPP |
This wire is primarily intended for fixed electrical installations in buildings, suitable for lighting, power, and control circuits where flexibility is required.
'H05' indicates a harmonized flexible cable with a 500V rating. 'V2' refers to PVC insulation with increased temperature resistance, and 'K' denotes a flexible conductor class 5.
This specific wire is designed for indoor fixed installations. For outdoor use, cables with appropriate weather and UV resistance ratings should be selected.
The conductor is made of copper.
The nominal voltage rating is 500V.
This product is a single-core wire, meaning it contains one conductor.
It means the cable meets specific European standards for reaction to fire, classified as 'eca' which is a basic level of fire performance for building materials.
Ensure you are using the correct H05V2-K type, which is designed for flexibility. If severe stiffness is encountered, check for damage to the conductor or insulation. Consider using a slightly larger bend radius.
Ensure the conductor end is properly stripped and inserted fully into the terminal. Tighten the terminal screw securely but do not overtighten, which could damage the conductor.
Immediately replace any section of wire with damaged insulation. Do not attempt to repair the insulation; use a new, undamaged piece of wire.
Setup:
Compatibility:
Care: