Powerful centrifugal extractor fan ideal in Bathrooms or Toilets. This model is for operation in c...Powerful centrifugal extractor fan ideal in Bathrooms or Toilets. This model is for operation in conjunction with the room light switch. When the light is switched on the fan comes on, when the light is switched off the fan continues to run for a pre-set time. Requires permanent live, switched live and neutral (3 wires excluding earth) at the fan position in order to operate correctly. Please note that the timer function cannot be used unless you have these three wires to connect.Designed to move air over long distances, these units will give maximum performance even against pressures caused by long lengths of ducting and resistance by grilles.The CF200 centrifugal fans use the latest technology to provide extremely powerful, yet very quiet and vibration free ventilation. The CF200 ranges are designed for bathrooms, toilets, cloakrooms, utility rooms.. Designed to move air over long distances, these units will give maximum performance even against pressures caused by long lengths of ducting and resistance by grilles.. All models are fitted with a built-in spring operated non-return flap into the discharge spigot to stop backdraughts.. There are seven models in each series. The CF200 has an extract rate of 110m3/hr 31 litres per second.. The units are all manufactured using high impact ABS thermoplastics for strength and durability, aesthetics and easy cleaning.. Power to the CF200 range is provided by a single phase induction motor with pre-oiled bearings for a long, maintenance-free life.. Designed to comply with the Building Regulations on Ventilation (F1).. Features:. Timer model incorporating integral adjustable electronic timer (1-20 mins). 100mm / 4" standard rigid or flexible duct. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3amp fuse fitted. The fan should not be accessible to a person using either the shower or bath and mounted to a minimum of 1.8 metres from the floor. Sapecifications:. Maximum pressure: 120 p.a.. Fan speed: 1400 r.p.m.. 110m3/hr, 31 litres per second. Diamensions: Height: 185mm x Width: 260mm x Depth: 90mm. Criteria. Noise Level: 45.0 dB(A). Wattage: 17. Voltage: 220-240V - AC. 50Hz. Width: 260. Height: 185. Manufacturer Code: CF200T. Barcode: 5020953551287
This guide provides essential information for users of the Manrose CF200T centrifugal extractor fan, designed for bathrooms, toilets, and utility rooms. It offers powerful and quiet ventilation, ideal for moving air over long distances. Note that the timer function requires specific wiring connections for proper operation. This guide covers key features, setup, troubleshooting, and frequently asked questions to help you effectively use and maintain your CF200T fan.
All features
Model Part Number
CF200T
Brand
Manrose
Extended Product Information
FAQs
How do I set the timer?
The timer setting is located within the fan housing. Refer to the product manual for detailed instructions on adjusting the timer duration (1-20 minutes).
What type of ducting should I use?
The CF200T is designed for use with 100mm / 4" standard rigid or flexible ducting.
Do I need to earth the fan?
No, the CF200T is double insulated and does not require an earth connection.
Where should I mount the fan?
The fan should be mounted a minimum of 1.8 meters from the floor and away from direct contact with water from showers or baths.
What if the fan is not extracting air effectively?
Check for any obstructions in the ducting or fan blades. Ensure the non-return flap is opening correctly. Also, make sure the fan is the correct model for the application.
Can I replace the fan motor?
The motor is designed for a long life and is pre-oiled for maintenance-free operation. If the motor fails, it's best to consult a qualified electrician or replace the unit.
What are the dimensions of the fan?
The dimensions are: Height: 185mm x Width: 260mm x Depth: 90mm.
Troubleshooting
Fan does not turn on.
Check the power supply and ensure the fan is correctly wired according to the instructions. Verify that the double pole isolating switch is on.
Fan runs continuously, even when the light is off.
Check the timer settings. Make sure the switched live wire is correctly connected to the fan.
Poor airflow.
Inspect the ducting for blockages and ensure the fan blades are clean. Check if the non-return flap is functioning correctly.
Fan is noisy.
Ensure the fan is properly mounted and that no objects are vibrating against it. Check for any obstructions in the ducting.
Pros and Cons
Pros
Effective at removing odors and humidity.
Timer function for post-use ventilation.
Quiet operation suitable for bathrooms and toilets.
Durable and easy-to-clean construction.
Suitable for long ducting runs.
Cons
Timer function requires specific wiring (permanent live, switched live, and neutral).
Installation requires knowledge of electrical wiring and compliance with regulations.
Requires a double pole isolating switch and 3amp fuse.
Fan must be mounted at least 1.8 meters from the floor.
Setup, Compatibility & Care
Installation:
Ensure all wiring complies with current IEE regulations.
Use a double-pole isolating switch with a contact separation of at least 3mm in all poles, and fit a 3 amp fuse.
The fan should be mounted at least 1.8 meters from the floor and not be accessible to a person using the shower or bath.
Wiring:
Requires permanent live, switched live, and neutral (3 wires, excluding earth) to operate correctly.
Double insulated, so no earth connection is required.
Ducting:
Compatible with 100mm / 4" standard rigid or flexible ducting.
Care:
Clean the fan regularly to maintain optimal performance. Use a damp cloth to wipe the exterior and internal components.