Knauf Frametherm Roll 32 is a premium glass mineral wool insulation with a 140mm thickness, provid...Knauf Frametherm Roll 32 is a premium glass mineral wool insulation with a 140mm thickness, providing 3.19m² coverage per roll. It is specifically designed for timber and light steel frame walls, offering high thermal efficiency and excellent sound absorption. Manufactured using Knauf’s ECOSE® Technology binder, this non-combustible insulation delivers superior performance with minimal environmental impact. Its low thermal conductivity of 0.032 W/mK ensures excellent heat retention in both residential and commercial buildings. The convenient roll format allows for easy cutting, fitting, and friction placement between studs without the need for fixings. The 140mm thickness is ideal for deeper frames in high-performance construction projects. This insulation is also recognized for providing the best thermal performance in its range and is designed to friction fit between timber studs, preventing air movement and minimizing heat loss. The rolls are pre-cut to suit common timber stud spacing.
140Mm Knauf Frametherm Roll 32 (3.19M2/Roll) LightFree delivery in 1–3 days£1,898.21Visit shop →
Product Information
Full details
The Knauf Frametherm Roll 32 - 140mm is designed for builders and renovators seeking superior thermal and acoustic insulation in timber and light steel frame walls. Its primary benefit is high thermal efficiency, reducing energy costs and improving comfort, though users must ensure proper handling due to its fibrous nature. This glass mineral wool insulation offers excellent heat retention and sound absorption, manufactured with ECOSE® Technology for reduced environmental impact and no added formaldehyde. Key features include its 140mm thickness for deep frames, low thermal conductivity (0.032 W/mK), non-combustible properties, and a convenient roll format with pre-cut lengths for easy friction fitting.
All features
Model Part Number
2435999
Brand
Knauf Insulation
Extended Product Information
FAQs
What is the R-value of Knauf Frametherm Roll 32 - 140mm?
The thermal conductivity is 0.032 W/mK. The R-value depends on the thickness used. For 140mm, the R-value is approximately 4.38 m²K/W (R = Thickness / Thermal Conductivity).
Is this insulation suitable for pitched roofs or floors?
While primarily designed for framed walls, its thermal and acoustic properties can be adapted for other applications like pitched roofs or between floor joists, provided it is correctly installed and supported.
How much area does one roll cover?
One roll covers 3.19m².
Does the ECOSE® Technology binder contain formaldehyde?
No, the ECOSE® Technology binder used in this insulation contains no added formaldehyde, phenol, or artificial colors.
Can I compress this insulation to fit a shallower space?
It is not recommended to compress mineral wool insulation as this significantly reduces its thermal performance. It is best to use the correct thickness for the cavity or cut it precisely to fit without compression.
What are the dimensions of the roll?
The roll is 140mm thick and covers 3.19m². Specific width and length would depend on the manufacturer's standard roll sizes for this product.
Is this product fire-rated?
Knauf Frametherm Roll 32 is non-combustible, contributing positively to the fire performance of the building elements it is installed within.
Troubleshooting
Insulation feels itchy or causes skin irritation.
Wear appropriate Personal Protective Equipment (PPE) including long sleeves, gloves, eye protection, and a dust mask during handling and installation.
Thermal performance seems lower than expected.
Ensure the insulation was installed without compression, gaps, or voids. Check for any thermal bridging around services or framing members and ensure air barriers are correctly installed.
Roll is difficult to cut cleanly.
Use a sharp, long-bladed insulation knife or a specialized insulation saw for clean, precise cuts. Ensure the insulation is laid flat for cutting.
Moisture detected within the insulation.
Ensure a correctly installed vapor control layer on the warm side of the insulation and a breathable membrane on the cold side. Address any leaks or sources of moisture ingress in the building envelope.
Pros and Cons
Pros
Excellent thermal insulation reduces heating and cooling costs.
ECOSE® Technology binder is formaldehyde-free and environmentally friendlier.
Non-combustible material contributes to fire safety.
Easy to cut and install, saving labor time.
Suitable for high-performance building designs requiring deep insulation.
Cons
Requires personal protective equipment (PPE) during installation to avoid skin, eye, and respiratory irritation.
Can be bulky to store and transport before installation.
Requires careful cutting and fitting to avoid thermal bridging.
Not suitable for exposed applications; must be covered by a vapor control layer and sheathing.
Performance can be compromised if installed incorrectly or compressed.
Setup, Compatibility & Care Instructions
Setup:
Preparation: Ensure the timber or light steel frame cavities are clear of debris. Wear appropriate personal protective equipment (PPE), including gloves, eye protection, and a dust mask.
Cutting: Use a sharp insulation knife or saw to cut the rolls to the required lengths. The rolls are often pre-cut to standard stud spacings, but verify measurements.
Installation: Unroll the insulation and place it into the wall cavities between the studs. Ensure it fits snugly without being compressed. The insulation should fill the entire depth of the cavity.
Finishing: Once insulation is in place, proceed with installing vapor control layers, membranes, and internal/external cladding as per building specifications.
Compatibility:
Designed for use in timber frame and light steel frame wall constructions.
Compatible with standard building practices for wall insulation.
Ensure compatibility with any adjacent building materials and moisture/vapor control systems.
Care:
Store rolls in a dry, protected area, ideally on pallets, to prevent moisture absorption and damage.
Avoid prolonged exposure to direct sunlight.
Once installed, the insulation is maintenance-free as it is enclosed within the building structure.
Handle with care during installation to maintain its integrity and thermal performance.