Theben Presence Detector - White

The theRonda S360-100 UP is a passive presence detector (IR) designed for flush-mounted ceiling in...

Best current price£92.90from Lights.co.uk

Colour

All Offers

3 offers from £92.90 - £107.84

View price history by clicking the chart icon.

Lights.co.ukTheben Theronda S360-100 Up Presence Sensor White
£4.99 delivery
£92.90
Visit shop
Tameson UKBeg White Luxomat Motion Switch (Complete) - 92442
Free delivery in 1–3 days
£104.48
Visit shop

Product Information

Full details

This guide is for users of the Theben theRonda S360-100 UP, a flush-mounted presence detector. The primary benefit of this device is automated lighting control, saving energy and increasing convenience. Keep in mind that correct installation and calibration are crucial for optimal performance. This guide covers setup, operation, troubleshooting, and frequently asked questions to help you get the most out of your presence detector.

All features

ColourWhite
Model Part NumbertheRondaS360-100UPWH
BrandTHEBEN

Extended Product Information

FAQs

What is the detection range of the theRonda S360-100 UP?

The detection area has a 360° field of view with a radius of approximately 9 meters, covering about 64 m².

What types of lamps are compatible?

The device is compatible with incandescent/halogen lamps, fluorescent lamps, and LED lamps.

Can I adjust the sensitivity of the detector?

Yes, you can adjust the brightness switching value and the light run-on time to customize the sensitivity.

What is the teach-in function?

The teach-in function allows the detector to learn and adapt to the ambient light conditions, enabling it to determine the appropriate brightness threshold for switching on the lights.

What is the mounting method for the detector?

The theRonda S360-100 UP is designed for flush-mounted installation in a ceiling.

What is the operating temperature range?

The ambient temperature range is -15 °C to +50 °C.

Does the device have a test mode?

Yes, a test operation is possible for function and detection range check.

Is the device suitable for staircase monitoring?

Yes, the theRonda S360-100 UP is suitable for staircase monitoring.

Troubleshooting

Lights do not turn on.

Check the power supply to the device and ensure the circuit breaker is not tripped. Verify that the brightness setting is appropriate for the ambient light conditions. Test the device's function by checking test operation mode.

Lights stay on constantly.

Check the brightness setting. The device might be detecting sufficient darkness to trigger the lights. Also check the follow-up time setting; it might be set too long. Ensure there are no obstructions in the detection area.

Detection range is too short.

Ensure there are no obstructions in the detection area. Check the mounting height; ensure it is within the recommended range (2 to 4 meters). Make sure the clips are not restricting the detection range.

Remote control does not work.

Ensure the remote control is compatible with the theRonda S360-100 UP (theSenda S, theSenda P, or theSenda B). Make sure the remote is within range of the detector. Check the remote control batteries.

Pros and Cons

Pros

  • Energy-efficient lighting control.
  • Wide detection range.
  • Adjustable settings for personalized control.
  • Easy installation with flush-mount design.
  • Compatible with various lamp types.
  • Remote control support for convenient adjustments.

Cons

  • Requires professional installation for optimal performance.
  • Remote control is sold separately.
  • Detection range might be affected by obstructions.
  • Settings adjustments may require some initial calibration.
  • Limited to indoor and outdoor applications with ceiling installations.
  • May require adjustments for optimal performance in specific environments.

Setup, Compatibility & Care

  1. Installation: The theRonda S360-100 UP requires flush-mounted installation in a ceiling using a Ø 55 mm mounting box. Installation should be performed by a qualified electrician to ensure safety and proper functionality.
  2. Wiring: Connect the device to the power supply using the screw terminals. Ensure proper wiring according to the provided instructions and local electrical codes. The maximum cable cross-section is 2 x 2.5 mm².
  3. Settings Adjustment: Use the adjustable brightness setting (30 to 3,000 lux) and follow-up time (pulse, 10 seconds to 60 minutes) to customize the detector's operation. The teach-in function can be used to set the brightness threshold based on ambient light conditions.
  4. Compatibility:
  • Lamps: Compatible with incandescent/halogen lamps (max. 2,300 W), fluorescent lamps (max. 1,150 VA), and LED lamps (max. 600 W for 2 W LED).
  • Mounting Height: The optimal mounting height is 2.5 meters, with a range of 2 to 4 meters.
  1. Care: Regularly inspect the detector for any obstructions within the detection area. Clean the device with a soft, damp cloth. Avoid using harsh chemicals or abrasive cleaners. Ensure that the ambient temperature remains between -15 °C and +50 °C for optimal performance.