LAPP OeLFLEX® CLASSIC 110 Control lead - 5 G 1.5 mm² - Grey

Control and connection cable, especially under industrial conditions. Mainly in dry, moist or wet ...

Best current price£33.22from Rapid Online - Rapid Electronics Ltd.

Colour

All Offers

20 offers from £33.22 - £66.60

View price history by clicking the chart icon.

Rapid Online - Rapid Electronics Ltd.LAPP 1119303/25 CLASSIC 110 Control lead 3 G 1.50 mm² Grey 25m reel
Free delivery in 1–3 days
£33.22
Visit shop
eBayLAPP CLASSIC 110 Control lead 3 G 1.50 mm² Grey 25m reel
Free delivery in 1–3 days
£33.28
Visit shop

Product Information

Full details

This LAPP OeLFLEX® CLASSIC 110 control lead is designed for professionals working under demanding industrial conditions, offering robust connectivity in dry, moist, or wet environments with normal mechanical load. Its key benefit lies in its high insulation safety and suitability for painting applications due to being free from LBS. However, it's important to note that outdoor use requires consideration of the temperature range and UV protection.

All features

ColourGrey
Model Part Number1119305/50
BrandRangemaster

Extended Product Information

FAQs

What is the primary application for this cable?

This cable is primarily designed for control and connection purposes under industrial conditions, especially in dry, moist, or wet rooms with normal mechanical load.

Can this cable be used outdoors?

Yes, but only under consideration of the temperature range and with adequate UV protection. It should not be exposed to direct sunlight without protection.

What does 'LBS-free' mean for this cable?

'LBS-free' means the cable is free from paint-wetting impairment substances, making it suitable for use in painting applications or environments without affecting paint finishes.

What is the test voltage for this cable?

The test voltage for this cable is 4000 V, indicating a high level of insulation safety.

What are the dimensions of each core conductor?

Each core conductor has a size of 1.5 mm².

What is the cable diameter?

The cable diameter is 8.1 mm.

Is this cable suitable for continuous movement?

No, this cable is designed for fixed installations or applications with light flexing, not for continuously moving applications or those with compulsory guidance and tensile loads.

Troubleshooting

Cable is stiff and difficult to bend.

Ensure the ambient temperature is within the specified range for flexing applications (-5 to 70°C). If outside this range, the cable's flexibility will be reduced.

Poor connection quality.

Verify that the tinned copper conductors are properly stripped and terminated into the connectors or terminals. Check for any corrosion or debris on the conductor ends.

Cable fails insulation test.

Inspect the entire length of the cable for any physical damage, cuts, or abrasions to the insulation. Ensure connections are secure and not causing strain.

Outdoor performance issues.

Confirm that UV protection measures are in place and that the ambient temperature is within the suitable range for outdoor fixed installation (-40 to 80°C).

Pros and Cons

Pros

  • Suitable for use in dry, moist, and wet rooms.
  • High insulation safety with a 4000 V test voltage.
  • Optimized small outer diameter for space-saving installations.
  • LBS-free, making it ideal for painting applications.
  • Flexible temperature range for diverse environmental conditions.

Cons

  • Outdoor use requires additional UV protection and adherence to temperature limits.
  • Not designed for continuously moving applications or compulsory guidance without tensile loads.
  • Requires specific installation considerations for flexing applications (minimum bending radius of 12.2 cm).

Setup, Compatibility & Care

Setup:

  1. Ensure the cable is routed according to the specified minimum bending radii: 3.24 cm for fixed installations and 12.2 cm for flexing applications.
  2. Connect conductors securely to appropriate terminals, adhering to electrical safety standards.

Compatibility:

  • This cable is designed for use with standard industrial control and power systems.
  • It is suitable for fixed installations and light flexing applications.
  • Ensure the ambient temperature falls within the specified operating ranges (-40 to 80°C fixed, -5 to 70°C flexing).

Care:

  • Periodically inspect the cable for any signs of damage to the insulation.
  • Clean the cable exterior with a dry or slightly damp cloth. Avoid harsh chemicals or solvents that could degrade the PVC insulation.
  • For outdoor installations, ensure appropriate UV protection and consider temperature extremes.

Price History