LAPP Hook Up Wire - Brown - 0.52 mm² - 22 AWG - 100m

LAPP Multi-Standard UL- MTW, CSA-HAR Single Core Wiring Cable - LAPP 4160103. Designed for control...

Best current price£0.58from RS Components Ltd- UK

Colour

All Offers

12 offers from £0.58 - £103.07

View price history by clicking the chart icon.

RS Components Ltd- UKLapp Brown 0.52 mm² Hook Up Wire, 22 AWG, 100m, PVC Insulation, 4160103
Free delivery in 1–3 days
£0.58
Visit shop
eBayLAPP 4160503 Wire
£13.20 delivery
£4.91
Visit shop
Tameson UKLapp Brown Sc 2.1 Ul Installation Wire - 4160303-100 [100 Meters] - Nominal Cross Section Conductor: 1 Mm2
Free delivery in 1–3 days
£51.42
Visit shop
Rapid Online - Rapid Electronics Ltd.LAPP 4160203 UL: MTW CSA-HAR Single Core Cable Brown 20AWG (100m)
Free delivery in 1–3 days
£52.13
Visit shop

Product Information

Full details

This LAPP Hook Up Wire is designed for control cabinet wiring, switchboards, and distribution panels, offering oil resistance and durability for demanding electrical applications. It is ideal for electricians and technicians working on internal wiring projects in various building types and transportation systems where fire safety is a concern. A key benefit is its multi-standard certification (UL, CSA, HAR), simplifying inventory and ensuring broad compatibility. However, its maximum operating temperature is limited to +70°C, which may not be suitable for extremely high-heat environments.

All features

ColourBrown
Model Part Number4160103
BrandLapp

Extended Product Information

FAQs

What does 'Multi-Standard' mean for this cable?

It means the cable meets the safety and performance standards of multiple regulatory bodies, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and HAR (European Harmonization). This allows it to be used in a wider range of international projects without needing different cable types.

Can this cable be used for mains power supply?

This cable is primarily intended for control cabinet wiring, switchboards, and internal building wiring, not for direct connection to mains power outlets or power distribution lines. Always check the specific application requirements against the cable's voltage and current ratings.

What is the advantage of a halogen-free cable?

Halogen-free cables produce significantly less smoke and fewer toxic/corrosive gases when exposed to fire compared to traditional PVC cables. This improves visibility for evacuation and reduces damage to electronic equipment and structures.

Is this brown wire suitable for all control signals?

The brown color is often used for specific functions, but its suitability for signals depends on the system's design and local electrical codes. This cable's technical specifications (22 AWG, 600V rating) make it generally suitable for control and signal applications within its temperature and environmental limits.

How should I store the remaining wire on the 100m spool?

Store the spool in a clean, dry area, protected from direct sunlight and extreme temperatures. Keep it on its side or upright to prevent the wire from unraveling or getting damaged. Covering the spool can help keep the wire clean.

What is the conductor material?

The conductor is made of fine wire tinned copper strands, which offers good conductivity and resistance to oxidation.

Can this wire be used outdoors?

This cable is intended for use in dry rooms and protected environments. It is not rated for direct exposure to outdoor weather conditions like rain, UV radiation, or extreme temperature fluctuations unless installed within a suitable protective conduit or enclosure.

Troubleshooting

Wire is difficult to strip cleanly.

Ensure you are using a wire stripper specifically designed for 22 AWG wire. Adjust the stripper settings if possible, or try a different stripping technique (e.g., scoring and pulling).

Intermittent connection at termination point.

Check that the conductor is fully inserted into the terminal and that the terminal screw is securely tightened. Ensure no stray wire strands are causing shorts or poor contact.

Cable feels stiff in cold temperatures.

While rated for -40°C, PVC insulation can become less flexible in extreme cold. Allow the cable to warm to room temperature before attempting complex bending or installation to prevent cracking.

Concern about heat resistance in a specific application.

Verify that the ambient temperature and the temperature generated by current flow do not exceed the cable's maximum operating temperature of +70°C. If they do, consider a cable with a higher temperature rating.

Pros and Cons

Pros

  • Excellent oil resistance for enhanced durability.
  • Multi-standard compliance (UL, CSA, HAR) simplifies usage.
  • Halogen-free design improves safety in fire situations.
  • Wide operating temperature range (-40°C to +70°C).
  • Tinned copper conductors ensure good conductivity and corrosion resistance.

Cons

  • Maximum operating temperature of +70°C may be limiting for high-heat applications.
  • PVC insulation might not offer the same flexibility as some other materials in extreme cold.
  • Single core design limits its use in applications requiring multiple conductors in one cable.

Setup, Compatibility & Care

Setup:

  1. Ensure the work area is clean and free from debris.
  2. Cut the wire to the required length using appropriate cable stripping tools.
  3. Carefully strip the insulation using a wire stripper designed for 22 AWG wire to avoid damaging the conductor.
  4. Connect the stripped conductor to the terminal or connector as per your project's electrical schematic.

Compatibility:

  • Voltage Rating: Suitable for applications up to 600V.
  • Temperature Range: Use within -40°C to +70°C.
  • Standards: Compatible with systems requiring UL (MTW, AWM), CSA (TEW), and HAR compliance.
  • Environment: Intended for use in dry rooms and protected environments.

Care:

  • Store the cable on its spool in a cool, dry place away from direct sunlight and sources of heat.
  • Avoid kinking or excessive bending, which can damage the insulation or conductor.
  • Regularly inspect the cable for any signs of physical damage, cuts, or abrasions, especially at connection points.
  • Clean the cable with a dry or slightly damp cloth if necessary. Avoid using solvents or harsh chemicals, which could degrade the PVC insulation.