The matt:e MTE/A 5P 100A 5 pole MCB provides a simple, cost effective, solution for PEN fault prot...The matt:e MTE/A 5P 100A 5 pole MCB provides a simple, cost effective, solution for PEN fault protection. This product has a C curve tripping characteristic and enables the connection of an EV charge point to the PME earthing facility without the use of earth electrodes. This product features a selectable manual or automatic reset function if a PEN fault is detected. Built-in PEN fault protection, No earth electrodes required, Available as 40A, 63A, and 100A, Simple wire in, wire out connection. Specifications: Breaking Capacity 6kA, Current Rating 100A, Mounting DIN Rail, No. of Poles 5, Tripping Characteristic Curve C, Type MCB, Voltage Rating 230/400V.
The matt:e MTE/A 5P 100A 5 pole MCB is designed for electricians and installers seeking a cost-effective and compliant solution for PEN fault protection, especially when connecting EV charge points to PME earthing facilities. Its key benefit is eliminating the need for separate earth electrodes, simplifying installation and reducing costs. A potential consideration is its specific C curve tripping characteristic, which is suited for particular load types. This MCB offers built-in PEN fault protection, a selectable manual or automatic reset function, and a simple wire-in, wire-out connection, supporting up to 100A with a 6kA breaking capacity.
All features
Model Part Number
MTE/A11-100M1A5P100A
Brand
matt:e
Extended Product Information
FAQs
What is a PEN fault and why is this MCB important?
A PEN fault occurs when the protective earth (PE) and neutral (N) conductors become disconnected or bonded incorrectly. This MCB provides integrated protection against such faults, which is crucial for safety, especially when connecting devices like EV chargers to PME earthing systems.
Do I still need earth electrodes with this MCB?
No, one of the key benefits of this matt:e MTE/A MCB is that it enables the connection of EV charge points to PME earthing facilities without the need for separate earth electrodes.
What is the difference between manual and automatic reset?
With manual reset, the MCB needs to be physically reset by hand after a PEN fault. With automatic reset, the MCB attempts to reset itself after a fault has cleared, offering convenience but requiring careful consideration of the installation's safety requirements.
Can this MCB be used for all types of electrical loads?
This MCB features a C curve tripping characteristic, which is generally suitable for circuits with moderate inrush currents, such as lighting, socket outlets, and standard EV chargers. For loads with very high inrush currents, a different curve (like D) might be more appropriate, and professional advice should be sought.
What are the available current ratings for this MCB model?
The matt:e MTE/A 5P MCB is available in 40A, 63A, and 100A current ratings. This guide specifically covers the 100A model.
What is the breaking capacity of this MCB?
The breaking capacity of this MCB is 6kA, meaning it can safely interrupt fault currents up to 6000 Amperes.
How do I determine if I need a 5-pole MCB?
A 5-pole MCB is typically required when you need to switch and protect all live conductors (L1, L2, L3) plus the neutral, especially in systems where neutral integrity is critical, such as with some EV chargers or specific industrial applications, and where PEN fault protection is also a requirement.
Troubleshooting
MCB trips frequently under normal load
Verify the load does not exceed the 100A rating. Check for loose connections. Confirm the C curve characteristic is appropriate for the connected load's inrush current.
MCB does not reset after a fault
Ensure the fault condition has been resolved. If set to manual reset, attempt to reset manually. If the issue persists, the unit may require inspection or replacement.
PEN fault detected, but MCB does not respond
Ensure the MCB is correctly wired and energized. Verify that the PEN fault detection circuit is functioning as expected. Consult the installation manual or a qualified electrician.
Unit is physically damaged
Do not attempt to install or use a damaged unit. De-energize the circuit and contact the supplier for a replacement.
Pros and Cons
Pros
Eliminates the need for additional earth electrodes, saving on installation time and materials.
Offers a compliant and cost-effective solution for connecting EV charge points to PME systems.
Includes a user-selectable reset function for adaptable fault response.
Compact design suitable for standard DIN rail mounting.
Robust breaking capacity of 6kA provides reliable protection against short circuits.
Cons
C curve tripping characteristic may not be suitable for all types of inductive loads with very high inrush currents.
Primarily designed for PEN fault protection scenarios, limiting its application scope.
Requires careful consideration of load characteristics to ensure correct MCB selection.
Setup, Compatibility & Care
Setup:
Mounting: Securely mount the MCB onto a standard 35mm DIN rail within a suitable enclosure.
Wiring: Connect the incoming live and neutral conductors to the designated terminals. Connect the outgoing conductors to the load terminals. Ensure all connections are tight and secure. Follow local wiring regulations.
Reset Function: Select the desired reset mode (manual or automatic) according to the installation requirements and local codes.
Compatibility:
Earthing System: Designed for use with PME earthing facilities.
EV Charge Points: Compatible with most EV charge points that require PEN fault protection.
Circuit Breaker Panels: Fits standard DIN rail mounting systems.
Voltage: Suitable for 230/400V AC systems.
Care:
Cleaning: Ensure the MCB is de-energized before cleaning. Wipe the exterior with a dry or slightly damp cloth. Avoid using solvents or abrasive cleaners.
Inspection: Periodically inspect the MCB for any signs of damage, overheating, or loose connections. Ensure the enclosure is clean and free from dust and debris that could impede ventilation.