PeakTech P 1650 Digital Clamp Meter - True RMS AC/DC 400A
PROFESSIONAL DEVICE: The P 1650 digital clamp meter allows contactless current measurements and fe...PROFESSIONAL DEVICE: The P 1650 digital clamp meter allows contactless current measurements and features a rugged, fireproof casing. A hand guard against accidental contact with the jaw offers safety. MEASURING FUNCTION: The device allows AC/ DC voltage and current measurements up to 600 V, as well as resistance, frequency, capacitance and temperature measurements and diode and continuity tests. DATA-HOLD FUNCTION: With the DATA-HOLD function, the measured value can be frozen in the LCD display and recalled at a later time. To exit the DATA-HOLD function, press the DATA-HOLD button again. LCD DISPLAY: The high-quality current probe with an illuminated display has a 3 ¾-digit LCD screen with 12 mm digits. Protection class: CAT III 600 V - The current clamp is suitable for electricians. INFO: Security: EN 61010-1 CAT III 600 V; Backlight; 3999 counts; Accessories: Type K temperature probe, carrying case, test leads, battery and manual; Dimensions: 70 x 197 x 40 mm, weight: 190 g. Absolute Maximum AC Voltage Measurement: 600V ac, Absolute Maximum DC Voltage Measurement: 600V dc, Clamp Meter Type: AC/DC Clamp Meter, True RMS: Yes, Safety Category: CAT III 600V.
Peaktech 1650 - Digital Clamp Meter With True Rms Ac/Dc 400A, 4000 Counts, Digital Multimeter, Current Measurement, Contactless Voltmeter, Ammete 4250569400377
OnBuy.comPeaktech 1650 - Digital Clamp Meter With True Rms Ac/Dc 400A, 4000 Counts, Digital Multimeter, Current Measurement, Contactless Voltmeter, Ammete 4250569400377
The PeakTech P 1650 is a digital clamp meter designed for electricians and technicians needing reliable contactless current measurements. Its key benefit is offering True RMS AC/DC voltage and current measurement up to 600V, along with a host of other essential functions in a rugged, safe design. A minor caveat is that while it measures AC/DC current, the clamp's primary strength lies in AC current measurements.
All features
Model Part Number
P 1650
Brand
PeakTech
Extended Product Information
FAQs
What is True RMS and why is it important?
True RMS (Root Mean Square) provides the most accurate measurement of AC voltage and current, especially for non-sinusoidal waveforms. This is crucial for understanding the actual power being delivered or consumed in circuits with electronic devices.
Can I measure DC current with this clamp meter?
Yes, the PeakTech P 1650 can measure both AC and DC current up to 400A through the clamp jaws.
What does CAT III 600V mean?
CAT III refers to a safety category rating. CAT III 600V means the meter is designed to safely withstand transient overvoltages up to 600V when measuring in fixed installations like building wiring and distribution panels, providing a high level of safety for the user.
How do I use the Data-Hold function?
Press the `DATA-HOLD` button once to freeze the current reading on the display. Press it again to release the hold and resume normal measurements.
What accessories are included with the P 1650?
The meter typically comes with a Type K temperature probe, carrying case, test leads, battery, and a user manual.
Is the display backlit?
Yes, the 3 ¾-digit LCD display features a backlight for improved readability in low-light conditions.
Can this meter measure resistance?
Yes, in addition to AC/DC voltage and current, the PeakTech P 1650 can measure resistance, frequency, capacitance, and temperature, and perform continuity and diode tests.
Troubleshooting
Display is blank or shows erratic readings
Check that the battery is installed correctly and has sufficient charge. Ensure the function and range are set appropriately. Verify test leads are securely connected for voltage/resistance measurements.
Inaccurate current readings
Ensure the jaws are clean and properly closed around the conductor. Make sure the meter is set to the correct AC or DC current mode. Avoid clamping around multiple conductors simultaneously unless intended.
Continuity test does not beep
Verify that the meter is set to the continuity mode and the test leads are connected correctly to the device and the circuit being tested. Ensure the circuit is de-energized. Check the resistance reading; a low resistance indicates continuity.
Data-Hold function not working
Press the `DATA-HOLD` button firmly to activate or deactivate the function. Ensure the meter is displaying a stable reading before activating Data-Hold.
Pros and Cons
Pros
True RMS for accurate measurements
Wide range of functions beyond current measurement
Contactless current measurement enhances safety
Durable construction suitable for professional use
Illuminated display aids visibility
CAT III 600V rating provides significant safety assurance
Cons
Primary focus on AC current measurement
May be overkill for basic DIY tasks
Requires careful handling to maintain accuracy
Setup, Compatibility & Care
Setup:
Install Battery: Open the battery compartment on the back of the device and insert the included 9V battery, observing correct polarity.
Connect Test Leads: Insert the red test lead into the `VΩmA` jack and the black test lead into the `COM` jack for voltage, resistance, capacitance, frequency, diode, and continuity tests. For current measurements, ensure the leads are not connected, as current is measured through the clamp.
Select Function: Rotate the dial to the desired measurement function (e.g., `A~` for AC current, `V-` for DC voltage).
Set Range: If the meter is not auto-ranging for the selected function, select the appropriate range.
Compatibility:
Safety Standard: CAT III 600V, suitable for work on distribution boards and fixed installations.
Temperature Probe: Compatible with Type K thermocouples.
AC/DC Voltage/Current: Measures AC and DC values up to 600V/400A.
Care:
Cleaning: Wipe the exterior with a dry or slightly damp soft cloth. Do not use solvents or abrasive cleaners.
Jaw Cleaning: Ensure the jaws are clean for accurate current readings. Use a soft cloth to remove any dirt or debris.
Storage: Store the clamp meter in its carrying case when not in use to protect it from dust and damage. Keep away from extreme temperatures and humidity.
Battery Replacement: Replace the battery when the low battery indicator appears on the display to ensure accurate measurements.