Wylex Main Switch Consumer Unit - 11 Way - 100A

This Wylex main switch consumer unit provides a safe and robust enclosure for housing your MCBs, R...

Best current price£88.96from B&Q

One Offer

1 offer from £88.96

View price history by clicking the chart icon.

B&QB&Q - Nm1106L 11 Way Main Switch And Rcd Main Switch Boards-11 Way
Free delivery in 1–3 days
£88.96
Visit shop

Used Offers

2 offers from £55.00

View price history by clicking the chart icon.

eBayWylex NM1106L 11 Way Main Switch and RCD Main Switch Board - Incl VAT
Free delivery in 1–3 days
£55.00
Visit shop

Product Information

Full details

This guide provides essential information for users of the Wylex Main Switch Consumer Unit, specifically the 11-way, 100A model. Designed for electricians and those undertaking electrical installations, this unit offers a safe and customisable solution for housing miniature protection devices. A key benefit is its ease of installation and compatibility with a wide range of Wylex miniature devices. Note that this unit requires professional electrical installation.

All features

Model Part NumberNM1106L
BrandWylex

Extended Product Information

FAQs

What is the main purpose of this consumer unit?

The main purpose of the Wylex Main Switch Consumer Unit is to provide a safe and organized enclosure for housing miniature circuit protection devices, protecting electrical circuits from overcurrent and short-circuit faults.

Can I install this unit myself?

No, this unit should only be installed by a qualified electrician to ensure compliance with safety regulations and proper functionality.

What types of devices can I install in this unit?

You can install Wylex miniature devices, including MCBs, RCBOs, and AFDDs. The unit is also compatible with the Wylex miniature Type 2 SPD.

What is the significance of the 100A main switch?

The 100A main switch is designed to handle the total current of the circuits connected to the consumer unit, providing a means of isolating the entire installation from the mains supply.

How do I know if the unit is overloaded?

If the circuit breakers trip frequently, it may indicate that a circuit is overloaded. Also, a qualified electrician should assess the connected devices and circuits for load capacity.

How often should I inspect the consumer unit?

It is recommended to inspect the consumer unit at regular intervals, typically annually, or more frequently if any issues are noticed.

Where can I find the technical specifications for this unit?

Detailed technical specifications, including dimensions and wiring diagrams, are usually found in the product documentation or on the manufacturer's website.

Troubleshooting

Unit not powering on.

Check the main switch and ensure the incoming power supply is active and properly connected. Verify the unit's internal connections for any loose wires or faults.

Circuit breakers tripping frequently.

Identify the specific circuit(s) tripping. Check for overloading of the circuit by reducing the number of appliances or devices connected. Inspect the connected devices for any faults or shorts. If the problem persists, consult a qualified electrician to assess the circuit and replace the faulty circuit breaker.

Difficulties fitting devices.

Ensure the miniature devices are fully compatible with the Wylex unit. Refer to the manufacturer's instructions for correct installation procedures. Make sure the devices are correctly aligned before insertion.

Pros and Cons

Pros

  • Easy installation with twin line and neutral supply terminals.
  • Fully customisable setup with compatibility with a wide range of Wylex miniature devices.
  • Enhanced safety features including a metal enclosure, curved visor, and temporary locking facility.
  • Includes a 100A main switch and fixed busbar assembly, saving time and effort.

Cons

  • Requires professional electrical installation.
  • Limited to Wylex miniature devices.
  • May require additional components depending on the specific setup.
  • The 11-way configuration may not be suitable for all installations needing more circuits.

Setup, Compatibility & Care

Setup

  1. Ensure the power supply is isolated before beginning installation.
  2. Mount the consumer unit securely to a wall.
  3. Connect the incoming supply cables to the main switch terminals.
  4. Install the appropriate miniature circuit breakers (MCBs), residual current circuit breakers with overcurrent protection (RCBOs), or arc fault detection devices (AFDDs) into the unit.
  5. Connect the outgoing circuit cables to the respective protection devices.
  6. Test all circuits to ensure correct operation.

Compatibility

  • The unit is compatible with all Wylex miniature devices, including MCBs, RCBOs, and AFDDs.
  • It also accepts the Wylex miniature Type 2 SPD (NMT2SPD3W/1).

Care

  • Regularly inspect the unit for any signs of damage or wear.
  • Keep the unit clean and free of dust and debris.
  • Ensure all connections are tight and secure.
  • Any maintenance or repairs should only be carried out by a qualified electrician.