Finder Interface Relay - 4C Series - 24V DC

This DIN rail mountable interface relay module from Finder features push-in terminal connections a...

Best current price£23.43from Tameson UK

All Offers

2 offers from £23.43 - £34.66

View price history by clicking the chart icon.

Tameson UKFinder 24V Dc Dual Interface Relay With Led Indicator - 4C.p2.9.024.0050
Free delivery in 1–3 days
£23.43
Visit shop
eBayInterface Relay 4C Series 2P 8A 24V 4C.P2.9.024.0050SPA
£13.20 delivery
£34.66
Visit shop

Product Information

Full details

This Finder Interface Relay, part of the 4C series, is designed for industrial automation and control applications. It offers reliable switching with dual changeover contacts, simplifying control circuits. A potential caveat is its specific 24V DC coil voltage, requiring a compatible power source. Key features include push-in terminals for quick connections, integrated LED status indication, and a protective flyback diode.

All features

Series4C
Model Part Number4C.P2.9.024.0050SPA
BrandFinder

Extended Product Information

FAQs

What is the main purpose of this interface relay?

This interface relay acts as a bridge between a control signal (e.g., from a PLC) and a load, allowing a low-power signal to control a higher-power circuit reliably and provide isolation.

What does 'dual changeover' mean for the contacts?

It means the relay has two independent sets of contacts. Each set consists of a common terminal, a normally open (NO) terminal, and a normally closed (NC) terminal. This allows for flexible switching configurations.

How do the push-in terminals work?

You simply strip the wire end and push it into the terminal opening. A spring mechanism grips the wire securely, eliminating the need for screws. To release, a small tool or screwdriver is typically used to push a release slot.

What is the function of the integrated LED?

The LED serves as a visual indicator that the relay coil is energized and the relay is active. This helps in quickly diagnosing if the control signal is reaching the relay.

What is a flyback diode and why is it important?

A flyback diode is installed across the coil to protect the control circuit from voltage spikes (inductive kickback) that occur when the coil is de-energized. It safely dissipates this energy.

Can I use this relay with AC and DC loads?

This relay is rated for AC loads up to 8A/250VAC. While it can switch DC loads, the maximum current and voltage ratings for DC are typically lower and depend on the load type (resistive, inductive). Always consult the product datasheet for specific DC load capabilities.

What is the IP rating and what does it mean?

The IP20 rating means the relay is protected against solid objects larger than 12.5mm (like a finger) and has no protection against water. It's suitable for dry, indoor environments like control cabinets.

Troubleshooting

Relay does not energize when power is applied

Verify the 24V DC power supply is connected correctly to terminals A1 and A2. Check that the power supply is active and providing the correct voltage. Ensure the relay module is fully seated in its socket.

Contacts do not switch when relay energizes

Confirm the LED indicator is lit when the coil is energized. If the LED is on but contacts do not switch, the relay may be faulty. Check the load wiring and ensure the load itself is functional.

Intermittent operation or failure to switch

Check all wiring connections for proper seating in the push-in terminals. Ensure the control signal is stable and within the correct voltage range. Verify the ambient temperature is within the operating limits.

Excessive heat from the relay

Ensure the load current does not exceed the relay's rated capacity (8A/250VAC). Check for proper ventilation in the control panel. A faulty relay may also overheat.

Pros and Cons

Pros

  • Tool-less push-in terminals speed up installation and maintenance.
  • Integrated LED provides clear status indication.
  • Built-in flyback diode protects control circuits.
  • Compact 15.8mm width saves valuable DIN rail space.
  • Wide operating temperature range (-40°C to +70°C) ensures reliability in harsh environments.
  • Complete assembly with socket, relay, and mounting clip simplifies procurement.

Cons

  • Requires a specific 24V DC power supply.
  • Not suitable for environments requiring higher IP protection ratings.
  • Dual changeover contacts may not be sufficient for highly complex switching requirements.
  • Monostable relay means it requires continuous power to remain in the energized state.

Setup, Compatibility & Care

Setup:

  1. Ensure the power supply voltage matches the relay coil voltage (24V DC).
  2. Mount the relay socket onto a standard 35mm DIN rail using the provided clip.
  3. Wire the control circuit to the coil terminals (A1, A2) and the load circuit to the changeover contacts (e.g., 11, 12, 14 for the first contact set).
  4. Connect the input wires securely into the push-in terminals. Push the wire in until it is firmly seated.
  5. Insert the relay module into the mounted socket.
  6. Connect the 24V DC power supply to the control circuit.

Compatibility:

  • Compatible with standard 35mm DIN rails.
  • Requires a stable 24V DC power source for the coil.
  • Suitable for switching AC loads up to 250VAC and 8A, and DC loads within specified limits (consult datasheet for DC load specifics).

Care:

  • Keep the relay and its socket clean and free from dust and moisture.
  • Periodically check wiring connections for tightness, especially if vibration is present.
  • Avoid exposing the relay to temperatures outside its specified operating range (-40°C to +70°C).
  • Ensure adequate ventilation around the control panel.

Price History

DatePrice
Visit shop