Proster Clamp Meter - 6000 Counts - 800A - TRMS

This 6000-count clamp meter offers True RMS measurements for AC/DC voltage (up to 600V) and AC/DC ...

Best current price£29.98from Amazon

All Offers

2 offers from £29.98 - £32.93

View price history by clicking the chart icon.

AmazonProster Orange 6000Counts 800A Clamp Meter True Rms 800A Ac Cat Ii 600V / Cat Iii 300V
Free delivery in 1–3 days
£29.98
Visit shop
OnBuy.comClamp Meter - Trms 6000 Counts 800A Dc/Ac Current 600V Dc/Ac Voltage Ncv Continuity Capacitance Resistance Frequency Diode Hz Test Auto Range Backlit 757347418813
Free delivery in 1–3 days
£32.93
Visit shop

Product Information

Full details

The Proster Clamp Meter (PSTTL301) is designed for electricians, technicians, and DIY enthusiasts needing accurate AC/DC voltage and current measurements. Its key benefit is True RMS (TRMS) for precise readings on non-linear loads, with a caveat that advanced functions require familiarity with electrical testing principles. This 6000-count meter offers auto-ranging, non-contact voltage (NCV) detection, continuity testing, and overload protection, making it a versatile tool for troubleshooting in various environments.

All features

Model Part NumberPSTTL301
BrandProster

Extended Product Information

FAQs

What is True RMS and why is it important?

True RMS (Root Mean Square) measurements provide the most accurate reading of AC voltage and current, especially on non-sinusoidal waveforms (like those from variable frequency drives or switching power supplies). Standard 'average-sensing' meters can be inaccurate in these situations.

How do I measure AC current with this clamp meter?

Set the dial to the appropriate AC current function (e.g., `A~`). Open the jaws of the clamp meter, place them around only ONE conductor of the circuit you want to measure, and close the jaws completely. The reading will appear on the display.

Can I measure DC current with this clamp meter?

Yes, this meter can measure DC current. Set the dial to the appropriate DC current function (e.g., `A-`). Open the jaws, place them around the conductor, and close them. For DC, polarity matters; the reading will show a negative sign if the current is flowing in the opposite direction through the jaws.

What is the difference between the `VΩmA` and the current input jacks?

The `VΩmA` jack is used for measuring voltage, resistance, continuity, capacitance, frequency, diode tests, and low current. The separate current jacks are specifically for measuring higher AC or DC current and prevent blowing internal fuses.

How do I use the NCV detection feature?

Select the NCV function on the dial. Bring the top sensing area of the clamp meter close to the suspected live AC conductor without touching it. The meter will beep and/or flash if AC voltage is detected.

What temperature range can the Type-K thermocouple measure?

The included Type-K thermocouple typically measures from -20°C to 250°C (-4°F to 482°F). Please refer to the specific product manual for exact specifications.

Does this meter have overload protection?

Yes, the Proster Clamp Meter features overload protection on all ranges to prevent damage to the device and ensure user safety.

Troubleshooting

Display shows no reading or '0000'

Ensure the test leads are properly inserted into the correct jacks and that the dial is set to the correct function. Check battery level.

Audible continuity beeper does not sound

Verify the dial is set to the continuity function and the resistance is very low (near zero). Ensure leads are making good contact.

NCV detection is not working

Ensure the meter is powered on and the NCV function is selected. The voltage must be AC and within the detection range of the sensor.

Inaccurate readings

Check if the meter is set to True RMS for non-sinusoidal waveforms. Ensure test leads are clean and making good contact. Test on a known reference if possible.

Overload Protection engages unexpectedly

Ensure the selected range is appropriate for the expected measurement. Do not exceed the maximum rated voltage or current for the selected function.

Pros and Cons

Pros

  • True RMS for accurate readings on various electrical loads.
  • Wide measurement range for both voltage and current (AC/DC).
  • User-friendly auto-ranging simplifies measurement selection.
  • Built-in NCV detection enhances safety during inspections.
  • Comprehensive set of functions for diverse electrical tasks.
  • Backlit display and flashlight improve usability in low light.

Cons

  • Requires user to understand basic electrical safety and testing procedures.
  • Can be complex for complete beginners due to its range of functions.
  • Type-K thermocouple accuracy may vary depending on ambient conditions.
  • Durability in harsh industrial environments may require additional protection.
  • Relies on batteries for operation, which need periodic replacement.

Setup, Compatibility & Care

Setup:

  1. Ensure the clamp meter is turned OFF.
  2. Connect the red test lead to the `VΩmA` jack and the black test lead to the `COM` jack for voltage, resistance, continuity, capacitance, and diode tests.
  3. For current measurements, select the appropriate `A` input jack (AC or DC) and ensure the jaws are fully closed around the conductor.
  4. Turn the dial to the desired measurement function and range (or use auto-range).
  5. For temperature, plug the thermocouple into the `VΩmA` and `COM` jacks and set the dial to `TEMP`.

Compatibility:

  • This meter is compatible with standard electrical circuits and components within its specified voltage and current limits.
  • It is suitable for AC and DC measurements.
  • The included test leads and thermocouple are compatible with the device.

Care:

  • Cleaning: Wipe the exterior with a dry or slightly damp cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the meter and accessories in the provided storage bag in a dry, cool place.
  • Battery Replacement: When the low battery indicator appears, replace the battery promptly with the specified type.
  • Calibration: While not user-serviceable for calibration, it is recommended to have the device professionally checked if accuracy is suspected.

Price History

DatePrice
Visit shop