OSRAM PTo 100/220-240 3DIM Special Lighting - 106 W
POWERTRONIC OUTDOOR PTo for HID lamps for outdoor applications. This electronic ballast is designe...POWERTRONIC OUTDOOR PTo for HID lamps for outdoor applications. This electronic ballast is designed for professional outdoor lighting installations with high-intensity discharge lamps. It features 3DIM functionality (StepDIM/AstroDIM/DALI), lightning protection up to 10 kV, an energy efficiency index of A2, and a luminous flux factor of 1 compared to CCG operation. Suitable for use in luminaires with IP54 protection or greater, and in luminaires of protection classes I and II. Offers excellent thermal behavior at very high limit temperatures (tc and ta) and high surge protection (up to 3 kV L-N / 4 kV L/N-PE). Achieves energy savings of up to 30% compared to CCG operation due to 3DIM functionality (except PTo 35). Includes automatic lamp shutdown in case of defects. Supply voltage: 220 to 240 V. Line voltage: 198 to 264 V. Line frequency: 50 to 60 Hz. Not suitable for DC operation. Instant hot restrike is not possible.
The OSRAM POWERTRONIC OUTDOOR PTo is an electronic ballast designed for professional outdoor lighting installations using high-intensity discharge lamps. It offers significant energy savings and enhanced protection features for reliable operation in demanding environments. A key benefit is its advanced 3DIM functionality for dimming control, however, it is not suitable for DC operation or instant hot restrike.
All features
Model Part Number
4008321956361
Brand
Osram
Extended Product Information
FAQs
What is the maximum surge protection for the OSRAM PTo?
The PTo offers high surge protection up to 3 kV between Line and Neutral (L-N) and up to 4 kV between Line/Neutral and Protective Earth (L/N-PE).
Can this ballast be used with LED lamps?
No, the POWERTRONIC OUTDOOR PTo is specifically designed for high-intensity discharge lamps, not LED lamps.
What does 3DIM functionality mean?
3DIM refers to the control options: StepDIM (manual or timed steps), AstroDIM (automatic dimming based on astronomical time), and DALI (Digital Addressable Lighting Interface), allowing for intelligent dimming and energy management.
Is this ballast suitable for indoor use?
No, this ballast is specifically designed for outdoor applications and must be installed in luminaires with IP54 protection or greater.
What is the supply voltage range?
The supply voltage range is 220 to 240 V AC. The line voltage range is 198 to 264 V AC. The line frequency is 50 to 60 Hz.
How does the automatic lamp shutdown feature work?
The ballast monitors the lamp's operating status and will automatically shut down power to the lamp if a defect is detected, preventing potential hazards and protecting the system.
What is the warranty period for this product?
Please refer to the specific warranty documentation provided by OSRAM or the authorized distributor for the exact warranty period.
Troubleshooting
Lamp does not ignite.
Verify power supply is on. Check all wiring connections for proper contact. Ensure the lamp is correctly seated and compatible with the ballast. Confirm the lamp is not defective.
Lamp flickers or operates erratically.
Check for loose connections in the wiring. Ensure the supply voltage is within the specified range (198-264 V). Verify the lamp is not nearing the end of its life or is not the correct type for the ballast.
Ballast overheats.
Ensure adequate ventilation around the ballast and within the luminaire. Check for obstructions in ventilation pathways. Confirm the ambient temperature is within the operational limits.
System trips circuit breaker.
Check for short circuits in the wiring or lamp. Ensure the ballast is correctly grounded. Verify the circuit breaker rating is appropriate for the load.
Pros and Cons
Pros
Significant energy savings up to 30% with 3DIM functionality.
Enhanced protection against lightning and power surges.
Reliable performance in harsh outdoor conditions.
Flexible lighting control options via DALI, StepDIM, and AstroDIM.
Automatic safety shutdown for defective lamps.
Cons
Not suitable for DC operation.
Instant hot restrike is not possible.
3DIM energy savings not applicable to the PTo 35 model.
Requires luminaires with IP54 protection or greater.
Setup, Compatibility & Care
Setup:
Ensure the power supply is switched off before installation.
Connect the supply voltage (220-240 V AC, 50-60 Hz) to the designated input terminals.
Connect the high-intensity discharge lamp to the output terminals according to the lamp and ballast specifications.
Ensure proper grounding for safety.
Install within a luminaire rated IP54 or higher and meeting protection class I or II requirements.
Compatibility:
Compatible with high-intensity discharge lamps designed for electronic ballast operation.
Requires a supply voltage of 220 to 240 V AC.
Not suitable for DC power sources.
Care:
Keep ventilation openings on the ballast and luminaire clear of obstructions.
Periodically inspect connections for tightness and signs of corrosion.
Clean the exterior of the ballast with a dry or slightly damp cloth. Avoid solvents or abrasive cleaners.
Ensure the luminaire housing remains properly sealed to maintain its IP rating.