Omron Power Supply Unit - CJ1W-PA205R

Best current price£350.31from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Omron Cj1w-Pa205r Power Supply Unit 100-240Vac - Cj1w0389b
Visit shop
Best current price£350.31from Tameson UK
Shopping.co.uk recommended and popular offers
Omron Cj1w-Pa205r Power Supply Unit 100-240Vac - Cj1w0389b
Visit shop1 offer from £350.31
View price history by clicking the chart icon.
1 offer from £104.71
View price history by clicking the chart icon.
This Omron Power Supply Unit (CJ1W-PA205R) is designed for industrial automation applications, specifically for powering CJ series PLC systems and their expansion modules. It provides a stable 5 VDC output from a wide 100-240 VAC input range, ideal for robust control environments. A key benefit is its dedicated RUN output signal for monitoring operational status. However, its compatibility is limited to CJ series PLCs, requiring careful system integration.
| Brand | Omron |
|---|
The Omron CJ1W-PA205R accepts a wide input voltage range of 100-240 VAC.
It provides a stable 5 VDC output with a maximum capacity of 5 Amperes (5A).
The RUN output signal indicates the operational status of the power supply. It confirms that the power supply is functioning correctly and providing stable output power.
This specific model, CJ1W-PA205R, is designed for Omron CJ series PLC systems, including the CJ1M series. Compatibility with other PLC series is not guaranteed.
The unit can operate reliably in ambient temperatures up to +55°C.
The dimensions are 81.6 mm (width) x 90 mm (height) x 80 mm (depth).
Ensure the unit is powered off. Use a soft, dry cloth or compressed air to remove dust from ventilation slots and the casing. Avoid using liquids or solvents.
Verify input voltage (100-240 VAC) is correctly connected to the power terminals. Check main circuit breaker and ensure local power is active. Confirm wiring integrity.
Check the 5 VDC output connections to the PLC backplane. Measure the output voltage directly at the unit's terminals using a multimeter. Ensure the total load does not exceed the 5A capacity.
Confirm the RUN output terminal is correctly wired to the monitoring circuit. Check if the input voltage is within the acceptable range (100-240 VAC). If the unit is operating normally and the RUN signal is still off, the unit may require service.
Ensure ventilation slots are clear of obstructions. Verify ambient operating temperature is within the specified limits (up to +55°C). Reduce the load if it is consistently near the 5A maximum.