PowerWalker Basic VI 3000 STL uninterruptible power supply (UPS) - PowerWalker - 10121194

Currently unavailable

Currently unavailable
The PowerWalker Basic VI 3000 STL is a Line-Interactive UPS designed for users needing essential power protection against failures and voltage fluctuations without a significant budget impact. Its compact tower form factor, USB connectivity for OS communication, and advanced LCD panel with a multi-functional button offer accessible management. While it provides reliable protection for essential devices, its 1-minute typical backup time at full load means it's best suited for graceful shutdown rather than extended operation during outages.
| Model Part Number | 10121194 |
|---|---|
| Brand | PowerWalker |
At full load (1800W), the typical backup time is approximately 1 minute. At half load (900W), it provides about 3.5 minutes of backup power. This is intended for safe shutdown.
This UPS produces a pseudo sine wave output. While suitable for most standard electronics, sensitive audio, video, or medical equipment may perform better with a pure sine wave UPS. Check your equipment's power supply requirements.
A quick double-click on the smart multi-functional button on the front panel will mute the audible alarm temporarily.
The internal battery (12V 7Ah) typically lasts 3-5 years under normal conditions. Replacement should be performed by qualified personnel. The UPS supports up to 4 batteries.
Line-Interactive UPS units monitor incoming power and use a transformer to correct minor voltage fluctuations (like sags and surges) using AVR without switching to battery power. This extends battery life and provides stable power.
Yes, a long-press of the smart multi-functional button on the LCD panel can be used to control the output of the UPS outlets.
The UPS operates within an input voltage range of 162 V to 290 V.
Ensure the power cord is securely connected to the UPS and a working wall outlet. Check if the wall outlet has power using another device. Press and hold the power button for a few seconds.
A continuous alarm typically indicates a power failure or overload. Check if the UPS is connected to mains power. If on battery, consider reducing the connected load. A double-click of the multi-functional button can mute the alarm temporarily.
Verify the USB cable is securely connected to both the UPS and the computer. Ensure the correct USB port drivers are installed. Restart the computer and the UPS.
Check if the UPS is turned on and has battery power or mains power. Verify that the connected equipment's power draw does not exceed the UPS's output capacity (1800W). Ensure equipment is plugged into the UPS outlets, not just pass-through outlets if available.
Batteries degrade over time. If the UPS is several years old, the battery may need replacement. Ensure the connected load is within the UPS's recommended capacity. Check the battery charge time; it typically takes 8 hours for a full recharge.
Setup:
Compatibility:
Care and Maintenance: