Underground Detectable Warning Tape Gas 150mm x 3M - Pegdev - PDL
Ensure the safety and accuracy of your excavation projects with our Underground Detectable Warning...Ensure the safety and accuracy of your excavation projects with our Underground Detectable Warning Tape, measuring 150mm. Crafted from robust 130-micron Polypropylene, this tape is designed to withstand the rigours of underground conditions. The inclusion of two stainless steel wires makes it detectable from the surface, providing an essential warning to avoid damaging buried pipes and services. Compliant with EN 12613 standards, this detectable tape is not only highly durable but also highly visible, thanks to its vibrant colouring. Each tape is clearly printed with the name of the service it marks, ensuring easy identification and added safety. Resistant to rot and capable of remaining intact even when stored in normal conditions away from direct sunlight, this tape is a reliable choice for long-term projects. Additionally, the tape is fully recyclable, making it an environmentally friendly option for your construction needs. Choose from various types and lengths to best suit your project requirements. Whether you're marking water pipes, Electrical lines, gas lines, or telephone cables, our Underground Detectable Warning Tape provides peace of mind and enhanced safety for all your underground work.
This Pegdev Underground Detectable Warning Tape (PDL) is designed for construction professionals and utility companies to ensure the safety of excavation projects by clearly marking underground gas lines. Its key benefit is the dual stainless steel wires, making it detectable by standard locating equipment, thus preventing accidental damage to buried infrastructure. A potential consideration is its specific application for gas lines, meaning other variants are needed for different utilities.
All features
Model Part Number
PDL
Brand
Pegdev
Extended Product Information
FAQs
What makes this tape detectable?
The tape contains two embedded stainless steel wires that can be detected by standard utility locating equipment from the surface.
What is the material of the tape?
The tape is constructed from robust 130-micron Polypropylene, making it durable and resistant to rot.
Is this tape suitable for all underground utilities?
No, this specific variant is marked for 'GAS' lines. Pegdev offers other variants for electrical, water, and telephone cables.
What standards does this tape comply with?
The tape is compliant with EN 12613 standards for underground warning tapes.
Can this tape be used in any soil conditions?
Yes, its durable construction allows it to withstand typical underground conditions. Ensure careful backfilling to avoid damage.
How should the tape be stored before use?
Store the tape in a cool, dry place away from direct sunlight to preserve its integrity.
Is the tape environmentally friendly?
Yes, the tape is fully recyclable.
Troubleshooting
Tape not detectable by locator.
Ensure the locator is functioning correctly and is set to detect metallic/conductive objects. Verify the tape is laid flat and not damaged. Check if the stainless steel wires are intact.
Tape appears damaged during installation.
Carefully inspect the tape for any tears or punctures. If significant damage is present, consider replacing the damaged section. Use care during backfilling to avoid further damage.
Difficulty in identifying the service type.
Ensure the 'GAS' marking is clearly visible and facing upwards. If markings are obscured, use alternative methods for service identification before excavation.
Pros and Cons
Pros
Provides essential warning to prevent accidental damage to gas lines.
Durable and resistant to underground conditions.
Easily detectable with standard locating equipment.
Clearly marked for immediate identification of buried service.
Compliant with safety standards.
Cons
Specific to marking gas lines; other variants are required for different utilities.
Requires appropriate locating equipment for detection.
Length is fixed at 3M for this specific variant, may require joining for longer runs.
Setup, Compatibility & Care
Setup:
Lay the tape directly above the buried gas line at a specified depth (refer to local regulations for exact depth requirements, typically 300-450mm below the surface).
Ensure the tape is laid flat and does not overlap itself. For longer runs, specific joining methods may be required, though this variant is 3M long.
Backfill the trench carefully, avoiding sharp objects that could damage the tape.
Compatibility:
Compatible with standard underground utility locating equipment designed to detect metallic or conductive elements.
Suitable for use with various backfill materials (soil, sand, gravel).
Care:
Store the tape in a cool, dry place away from direct sunlight to maintain material integrity.
Inspect tape for damage before installation.
While durable underground, avoid prolonged exposure to extreme abrasion or cutting tools during installation.