Hager ST Bell Transformer - ST314

This ST safety transformer is capable of converting the voltage of 230 V into a voltage of 12 - 24...

Best current price£79.00from Amazon

All Offers

3 offers from £79.00 - £158.35

View price history by clicking the chart icon.

AmazonHager Dane 12661 St314 - Transformer 40Va 230/12-24V
Free delivery in 1–3 days
£79.00
Visit shop
Tameson UKHager St Bell Transformer - St314
Free delivery in 1–3 days
£146.39
Visit shop
eBaySafety Transformer 230/12-24V AC 40VA ST314
£15.60 delivery
£158.35
Visit shop

Product Information

Full details

This Hager ST314 safety transformer is designed for electricians and technicians who need to convert 230V AC input to a lower voltage of 12-24V AC. Its key benefit is providing a reliable, short-circuit proof power conversion for various low-voltage applications. A caveat to consider is its maximum operating temperature of +35°C, requiring adequate ventilation in warmer environments.

All features

Model Part NumberST314
BrandHAGER

Extended Product Information

FAQs

What is the primary purpose of the Hager ST314?

The Hager ST314 is a safety transformer designed to convert a standard 230V AC input voltage into a lower 12V AC or 24V AC output voltage for low-voltage applications.

Is the transformer suitable for outdoor use?

While it can operate in a wide temperature range (-20°C to +35°C), it is typically intended for installation within an electrical enclosure. It is not inherently weatherproof and should be protected from direct moisture and environmental elements.

Can I use this transformer for DC devices?

No, this transformer provides an AC output voltage (12V or 24V AC). It is not suitable for devices that require a DC power supply.

How do I select between 12V and 24V output?

The selection between 12V and 24V output is typically made via an internal switch or terminal configuration on the transformer itself. Refer to the specific markings on the unit or consult the installation manual for precise instructions.

What does 'short-circuit proof' mean for this transformer?

It means the transformer has built-in protection that prevents permanent damage if a short circuit occurs on the output side. However, it is still important to rectify any short circuits promptly.

What is the maximum frequency it operates at?

The transformer operates at a maximum frequency of 50Hz.

What size conductors can be used for connection?

The connection section is designed for flexible conductors up to 4 mm².

Troubleshooting

Transformer not providing output voltage

Verify that the 230V AC input power is correctly connected and live. Check that the output voltage (12V or 24V) is correctly selected. Ensure all connections are secure and that the connected device is not causing a short circuit.

Device connected to transformer is not working

Confirm that the transformer's output voltage (12V or 24V) matches the required input voltage of the connected device. Check the wiring between the transformer and the device for continuity and correct connections.

Transformer overheating

Ensure the transformer is not operating above its maximum ambient temperature of +35°C. Check for adequate ventilation around the unit. Reduce the load if it's consistently exceeding the transformer's capacity. Verify there are no internal short circuits.

Intermittent power output

Inspect input and output wiring for loose connections or damaged conductors. Ensure the load is within the transformer's specified capacity. Check for any environmental factors causing fluctuating temperatures.

Pros and Cons

Pros

  • Reliable voltage conversion for low-voltage applications.
  • Built-in short-circuit protection for enhanced safety.
  • Easy integration into standard electrical panels via DIN rail mounting.
  • Durable construction for long-term use.
  • Suitable for a wide range of ambient temperatures.

Cons

  • Limited to a maximum operating temperature of +35°C, requiring careful placement in hot environments.
  • Output voltage is fixed at 12-24V AC, not suitable for DC applications or other voltage requirements.
  • Requires manual selection of output voltage (12V or 24V) which might be overlooked.
  • Requires a 230V AC input supply.

Setup, Compatibility & Care

Setup:

  1. Mounting: Securely mount the transformer onto a standard DIN rail within an appropriate electrical enclosure.
  2. Input Connection: Connect the 230V AC input supply to the designated input terminals. Ensure power is switched off before making connections.
  3. Output Selection: Adjust the internal setting or terminals to select either 12V AC or 24V AC output as required by your connected device.
  4. Output Connection: Connect your low-voltage device (e.g., doorbell, light) to the 12V AC or 24V AC output terminals using appropriate wiring.
  5. Verify Connections: Double-check all wiring for correct polarity and secure connections.

Compatibility:

  • Input Voltage: Compatible only with a 230V AC, 50Hz power supply.
  • Output Voltage: Provides 12V AC or 24V AC output. Ensure your connected device is designed to operate on one of these voltages and AC power.
  • Wiring: Designed for use with flexible conductors up to 4 mm².
  • Mounting: Requires a standard DIN rail for installation.

Care:

  • Cleaning: Disconnect power before cleaning. Wipe the exterior with a dry or slightly damp cloth. Avoid using solvents or abrasive cleaners.
  • Ventilation: Ensure adequate airflow around the transformer, especially in warm environments, to stay within its +35°C operating limit. Do not install in sealed, unventilated enclosures if ambient temperatures are high.
  • Inspection: Periodically inspect for any signs of damage or loose connections.

Price History

DatePrice
Visit shop