Product Information

Full details

The FlexiGas CSST Gas Installation Contractor Kit is designed for plumbers and contractors looking for a faster, easier, and more affordable solution for gas installations. It offers superior value for new builds, retrofits, and refurbishments. This kit includes a 32mm x 15m pipe and 2x copper unions, providing a flexible yet robust system for various gas line needs. A key caveat to consider is the need for specific training and tools for proper installation and certification.

All features

Model Part NumberCK32-15M-CC
BrandFlexiGas

Extended Product Information

FAQs

What type of gas can be used with FlexiGas CSST?

FlexiGas CSST is designed for use with natural gas and propane.

What is the minimum bend radius for the 32mm pipe?

Refer to the FlexiGas installation manual for the specific minimum bend radius for the 32mm CSST to avoid damaging the pipe.

Do I need special tools to install FlexiGas?

Yes, specialized tools are required for cutting, terminating, and connecting FlexiGas CSST to ensure a safe and compliant installation.

Can this system be buried underground?

CSST systems are generally not designed for direct burial. Consult local codes and manufacturer guidelines for appropriate underground installation methods, which typically involve conduit.

What is the warranty period for FlexiGas products?

Warranty information can typically be found in the product documentation or on the manufacturer's website. It is recommended to consult the official FlexiGas resources for the most accurate warranty details.

Where can I find the installation certificate?

The installation certificate for this FlexiGas system can be found at: https://flexigas.com/wp-content/uploads/2021/06/KM598726Issued20-1-15.pdf

Is this kit suitable for all types of buildings?

This kit is designed for a wide range of installations, including new builds, retrofits, and refurbishment work. Always ensure compliance with local building codes and gas regulations for your specific application.

Troubleshooting

Gas leak detected at connection point

Immediately shut off the gas supply. Retighten or re-make the connection using the correct tools and procedures. Perform a new leak test with an approved solution.

Low gas pressure to appliances

Check for any kinks or damage in the CSST run. Ensure all valves are fully open. Verify that the pipe size is adequate for the total appliance load and distance. Consult manufacturer specifications for pressure drop charts.

Difficulty making a secure connection

Ensure the end of the CSST is properly prepared (cut square, no burrs) and that the correct fitting and tools are being used. Refer to the FlexiGas installation manual for detailed connection instructions.

Pipe appears kinked or crushed

Do not attempt to use kinked or crushed sections of pipe. Cut out the damaged section and replace it using appropriate fittings and connection techniques. Ensure proper support is used to prevent future kinking.

Pros and Cons

Pros

  • Significantly reduces installation time and labor costs.
  • Flexible tubing simplifies routing in complex spaces.
  • Durable stainless steel construction ensures longevity.
  • Cost-effective alternative to traditional piping methods.
  • Suitable for a wide range of residential and commercial applications.

Cons

  • Requires specialized tools and training for proper installation.
  • May not be suitable for extremely high-pressure applications without specific system design.
  • Susceptible to damage from sharp objects if not properly protected during installation.
  • Specific code requirements may vary by local jurisdiction.
  • Can be more expensive upfront per linear foot than basic black iron pipe.

Setup, Compatibility & Care

Setup: Proper installation of the FlexiGas CSST system requires adherence to manufacturer guidelines and local building codes. This includes using the correct tools for cutting, bending, and connecting the tubing, as well as proper support and protection of the pipe. Ensure all connections are leak-tested according to industry standards.

Compatibility: The FlexiGas system is designed for use with natural gas and propane. The included copper unions are suitable for connecting to standard copper or black iron gas fittings. Always verify compatibility with specific appliances and local gas utility requirements.

Care: The corrugated stainless steel tubing is corrosion-resistant. However, it should be protected from physical damage during and after installation. Avoid sharp bends beyond the specified minimum radius and ensure the pipe is not subjected to excessive stress or impact. Regular visual inspections for any signs of damage are recommended.