Kenable Signal Cable - 6 Core - White

6 core alarm or signal cable. Suitable for most low voltage applications requiring a 6 core cable....

Best current price£32.33from B&Q

One Offer

1 offer from £32.33

View price history by clicking the chart icon.

B&QB&Q - 6 Core Cca Signal Cable For Alarm Or Intercom Systems 100M White
Free delivery in 1–3 days
£32.33
Visit shop

Product Information

Full details

This Kenable 6-core white signal cable is ideal for low-voltage alarm and signal applications where multiple distinct channels are needed. Its color-coded cores simplify identification and installation, and a rip cord facilitates easy jacket removal. A key caveat is that it is constructed with Copper Clad Aluminum (CCA) conductors, making it unsuitable for carrying power.

All features

ColourWhite
Model Part Number11104
Brandkenable

Extended Product Information

FAQs

Can I use this cable to power a device?

No, this cable is made from Copper Clad Aluminum (CCA) conductors and is not suitable for carrying power. It is intended only for low-voltage signal and alarm applications.

What does '6 core' mean?

'6 core' means the cable contains six individual insulated conductors, each typically color-coded for easy identification, allowing you to run six separate signal paths within a single cable.

How do I identify which wire to use?

The cable features color-coded cores for easy identification. Refer to your specific device's wiring diagram to match the correct color to the required terminal.

What is the maximum length I can run this cable?

The maximum effective length depends on the signal type and required data rate. For low-voltage signaling, it can be run over significant distances, but excessive length may lead to signal degradation. Always test with your specific application.

Is the meter marking accurate?

The meter marking is intended as a guide for measurement and inventory. For critical installations requiring precise lengths, it is advisable to measure and verify with a tape measure.

What is CCA and why is it important?

CCA stands for Copper Clad Aluminum. It means the aluminum conductors are coated with a thin layer of copper. This construction is less expensive than pure copper but has higher electrical resistance, making it unsuitable for power transmission where voltage drop and heat generation are concerns.

Can I use this outdoors?

The white PVC jacket provides some protection, but the cable is not rated for direct burial or harsh outdoor environments without additional protective conduit or sheathing. It is best suited for indoor or protected outdoor installations.

Troubleshooting

No signal detected on one or more cores

Verify that the corresponding colored core is securely connected at both ends. Check for breaks in the conductor using a multimeter (continuity test). Ensure the insulation has been properly stripped without damaging the conductor.

Intermittent signal loss or noise

Check for loose connections. Ensure the cable is not routed too close to high-power electrical sources, which can cause interference. Verify that the cable has not been physically damaged or kinked.

Difficulty stripping the outer jacket

Ensure you are using the designated rip cord. If the rip cord breaks, carefully use a sharp blade or cable stripper, taking care not to cut into the inner conductors.

Cable appears damaged

Do not use the damaged section. Cut out the damaged portion and re-terminate the cable ends, or replace the entire cable if the damage is extensive.

Pros and Cons

Pros

  • Easy identification of cores due to color coding.
  • Convenient jacket removal with the integrated rip cord.
  • Suitable for a variety of low-voltage signaling tasks.
  • Meter marking aids in accurate cable management.
  • Provides six distinct channels for flexible signal routing.

Cons

  • Not suitable for power transmission due to CCA conductors.
  • CCA conductors may have higher resistance than pure copper over long runs.
  • External diameter might be a consideration for very tight installations.
  • Color coding might be limited in very specific, complex system requirements.

Setup, Compatibility & Care

Setup:

  1. Identify Application: Ensure the cable is used only for low-voltage alarm or signal transmission, not for mains power.
  2. Measure and Cut: Use the meter markings to cut the required length. Allow extra for connections.
  3. Strip Jacket: Use the rip cord to carefully strip back the white PVC jacket, exposing the colored cores.
  4. Strip Cores: Gently strip a small amount of insulation from the end of each required core.
  5. Connect: Connect the color-coded cores to the appropriate terminals on your devices or control panels. Refer to your equipment's manual for specific wiring diagrams.

Compatibility:

  • Suitable for most low-voltage systems including alarm panels, intercoms, doorbell circuits, and basic data transmission where signal integrity is key.
  • Ensure voltage requirements of your connected devices do not exceed the cable's 500Vrms rating.
  • Not compatible with any application requiring power delivery due to CCA construction.

Care:

  • Store in a cool, dry place away from direct sunlight.
  • Avoid sharp bends or kinking the cable during installation or handling.
  • Protect the cable from physical damage, abrasion, or excessive moisture in its operating environment.
  • Periodically inspect visible sections of the cable for any signs of damage.

Price History

DatePrice
Visit shop