PDU UK Sockets 6 Way - Kenable - 011536

1U 6 way Horizontal 13A switched PDU designed for standard networking or data cabinets equipment t...

Best current price£29.53from OnBuy.com

All Offers

2 offers from £29.53

View price history by clicking the chart icon.

OnBuy.comKenable Pdu Uk Sockets 6 Way With Uk Plug Power Distribution Unit Horizontal 5M
Free delivery in 1–3 days
£29.53
Visit shop

Product Information

Full details

This Kenable 6-way UK socket PDU is designed for IT professionals and network administrators looking to efficiently power equipment within standard 19-inch networking or data cabinets. Its primary benefit is providing organized, accessible power distribution for multiple devices. A key consideration is its fixed 5m power lead length, which may require planning for optimal placement. The unit offers six 13A switched UK sockets in a slimline 1U form factor, featuring a power switch with a protective cover and an earth stud for enhanced safety.

All features

Model Part Number011536
Brandkenable

Extended Product Information

FAQs

What is a PDU?

A PDU stands for Power Distribution Unit. It's essentially a power strip designed to distribute power to multiple devices, often within a rack or cabinet environment.

What is the maximum load for this PDU?

This PDU is rated for 13 amps, which is the standard for UK sockets. Ensure the total power consumption of your connected devices does not exceed this limit.

Can I switch each socket individually?

No, this model features a single main power switch with a protective cover that controls all 6 sockets simultaneously. It does not have individual switches per socket.

What does the '1U' designation mean?

'1U' refers to Rack Unit, a standard measurement for the height of equipment designed to fit in a 19-inch rack. 1U is approximately 1.75 inches (44.45 mm) in height.

Is the power lead detachable?

No, the 5-meter power lead is permanently attached to the PDU.

Does this PDU have surge protection?

This product description does not specify surge protection capabilities. It is a basic power distribution unit.

What is the purpose of the earth stud?

The earth stud provides a dedicated connection point for grounding your equipment, which is crucial for safety and protecting sensitive electronics from electrical faults or static discharge.

Troubleshooting

PDU not powering connected devices

Check that the main power switch is in the 'ON' position. Ensure the PDU's 5m power lead is securely plugged into a live power outlet. Verify the power outlet itself is functional by testing with another device.

Some sockets not working

Inspect the individual plugs of the connected devices to ensure they are fully inserted into the PDU sockets. If multiple sockets are affected, it may indicate an internal issue; contact support.

Overheating or unusual noise

Immediately switch off the PDU and unplug it from the power source. Check that the total power draw of connected devices does not exceed the 13A rating. Remove any obstructions and allow the unit to cool before attempting to use it again. If the problem persists, discontinue use and contact support.

Pros and Cons

Pros

  • Provides organized power distribution for up to six devices.
  • Slimline 1U design saves valuable rack space.
  • Individual socket switching (via main switch) allows for controlled power management.
  • Includes an essential earth stud for safety.
  • Durable construction suitable for demanding environments.

Cons

  • Fixed 5m power lead may not suit all installation lengths.
  • Only suitable for standard 19-inch rack cabinets.
  • Switch is a single main switch, not individual switches per socket.

Setup, Compatibility & Care

Setup:

  1. Mount the PDU horizontally into a standard 19-inch rack or cabinet using the provided mounting points.
  2. Connect the 5-meter power lead to a suitable 13A power outlet.
  3. Attach the earth lead from your equipment to the integrated earth stud on the PDU chassis.
  4. Plug your networking or data equipment into the 6 UK sockets.
  5. Flip the main power switch to the 'ON' position. The protective cover should be closed to prevent accidental switching off.

Compatibility:

  • Designed for 19-inch standard networking and data cabinets.
  • Compatible with all standard UK 3-pin (13A) plugs.
  • Suitable for powering most low to medium power IT and networking equipment.

Care:

  • Ensure the PDU is kept clean and free from dust and debris. Wipe with a dry or slightly damp cloth as needed. Do not use abrasive cleaners.
  • Periodically check the power lead and plug for any signs of damage.
  • Ensure the power switch cover is securely closed when in use to prevent accidental power loss.

Price History

DatePrice
Visit shop