APC Basic Rack PDU - AP6020A - Black

The APC by Schneider Electric basic Rack PDU distributes power to the devices in the rack. The Rac...

Best current price£78.72from PCHUB.UK

All Offers

5 offers from £78.72 - £94.46

View price history by clicking the chart icon.

PCHUB.UKApc Black Ap6020a Power Distribution Unit (Pdu) 13 Ac Outlet(S) 0U/1U
Free delivery in 1–3 days
£78.72
Visit shop
Laptops Direct (BID)Apc Basic Rack Pdu - Power Distribution Unit Rack-Mountable - Ac 100-240V - Input_iec 60320 C20 - Output Connectors_ 13 Black, Laptops Direct - AP6020A
£6.95 delivery
£92.97
Visit shop
Servers Direct (BID)Apc Black Basic Rack Pdu - Power Distribution Unit Rack-Mountable - Ac 100-240V - Input_iec 60320 C20 - Output Connectors_ 13
£6.95 delivery
£92.97
Visit shop
PcNova.co.ukApc Black Ap6020a Power Distribution Unit (Pdu) 13 Ac Outlet(S) 0U/1U
Free delivery in 1–3 days
£94.15
Visit shop
GamingKitApc Black Ap6020a Power Distribution Unit (Pdu) 13 Ac Outlet(S) 0U/1U
Free delivery in 1–3 days
£94.46
Visit shop

Product Information

Full details

This guide is for IT professionals and data center managers using the APC Basic Rack PDU (AP6020A). It helps distribute power efficiently to rack-mounted equipment, offering a cost-effective solution. A key benefit is the ability to power multiple devices from a single branch whip, saving time and money during installation. Keep in mind that this PDU provides basic power distribution and does not offer remote monitoring capabilities.

All features

ColourBlack
Model Part NumberAP6020A
BrandA.P.C.

Extended Product Information

FAQs

What is the maximum load capacity of the PDU?

The maximum load capacity is 3680W.

What type of power cord does the PDU use?

The PDU uses an IEC-320 C20 inlet and requires a separate power cord.

What type of outlets does the PDU have?

The PDU has 13 C13 outlets.

Does the PDU have remote monitoring?

No, this PDU does not have remote monitoring capabilities.

What are the mounting options for the PDU?

The PDU can be mounted horizontally or vertically.

What is the input voltage range?

The input voltage range is 100-240V.

What certifications does the PDU have?

The PDU is certified with cUL Listed, CE, EAC, IRAM, PSE, UL Listed, VDE, and REACH.

Troubleshooting

PDU not powering on.

Check the power cord connection and the circuit breaker. Ensure the power source is active.

Devices not receiving power.

Verify that the devices are switched on and that the PDU outlets are functioning. Check the device's power cord.

Overload.

Disconnect some devices to reduce the load. Check the total power draw to ensure it does not exceed the PDU's capacity.

PDU is hot.

Check for proper ventilation and reduce the load if necessary.

Pros and Cons

Pros

  • Cost-effective power distribution solution.
  • Multiple outlets for connecting various devices.
  • Wide input voltage range for global compatibility.
  • Flexible mounting options (horizontal/vertical).
  • Supports high power loads.
  • Complies with multiple safety certifications.

Cons

  • No remote monitoring capabilities.
  • Basic power distribution features only.
  • Requires a separate power cord (not included).
  • Does not include surge protection.
  • Limited to 13 outlets.

Setup, Compatibility & Care

Setup

  1. Mounting: Choose the appropriate mounting configuration (horizontal or vertical) and secure the PDU to the rack.
  2. Power Cord Connection: Connect a compatible power cord (IEC-320 C20 to the appropriate plug type) to the PDU.
  3. Device Connection: Plug your rack-mounted devices into the C13 outlets.
  4. Power On: Once all devices are connected, switch on the PDU.

Compatibility

The APC Basic Rack PDU (AP6020A) is compatible with standard 19-inch racks.

  • Input Voltage: 100-240V
  • Outlets: 13 x C13
  • Inlet: IEC-320 C20

Ensure that the combined power consumption of your connected devices does not exceed the PDU's maximum load capacity (3680W).

Care

  • Cleaning: Use a dry cloth to clean the exterior of the PDU.
  • Inspection: Regularly inspect the PDU for any signs of damage.
  • Ventilation: Ensure proper ventilation around the PDU to prevent overheating.