APC APDU9953 PDU - 24 AC Outlet(s) - 0U - Black

APC Switched Rack PDUs offer advanced load management with on/off outlet-level power cycling and s...

Best current price£1,026.27from PCHUB.UK

All Offers

12 offers from £1,026.27 - £1,405.68

View price history by clicking the chart icon.

PCHUB.UKApc Black Apdu9953 Power Distribution Unit (Pdu) 24 Ac Outlet(S) 0U
Free delivery in 1–3 days
£1,026.27
Visit shop
Box.co.ukApc Size 24 Black Apdu9953 Ac Outlets Power Distribution Unit (Pdu)
Free delivery in 1–3 days
£1,034.95
Visit shop
Laptop OutletApc Black Apdu9953 Power Distribution Unit (Pdu) 24 Ac Outlet(S) 0U
Free delivery in 1–3 days
£1,034.95
Visit shop
Laptops Direct (BID)Apc Switched Rack Pdu - Power Distribution Unit Rack-Mountable - Ac 230V - Ethernet 10/100/1000 - Input_iec 60309 32A Black, Laptops Direct - APDU9953
£6.95 delivery
£1,209.97
Visit shop
Servers Direct (BID)Apc Black Switched Rack Pdu - Power Distribution Unit Rack-Mountable - Ac 230V - Ethernet 10/100/1000 - Input_iec 60309 32A
£6.95 delivery
£1,209.97
Visit shop

Product Information

Full details

This guide is for IT professionals and data center managers looking to optimize power distribution in their racks. The APC Switched Rack PDU (APDU9953) offers advanced power management, including outlet-level control and monitoring, leading to improved uptime and efficiency. A key consideration is ensuring proper rack compatibility for installation.

All features

ColourBlack
Model Part NumberAPDU9953
BrandA.P.C.

Extended Product Information

FAQs

What is the operating temperature range?

The operating temperature is -5 to 45 °C. Select 9000 series PDUs can operate in a maximum ambient air temperature of 60C (140F) at full load.

What types of outlets are available on this model?

This model (APDU9953) features C13 and C19 coupler outlets.

Does this PDU support remote management?

Yes, it supports remote management via Web, SNMP, and Telnet.

What is the power input connection?

The power input connection is IEC 60309.

Can I monitor power consumption?

Yes, the PDU provides 1% metering accuracy for precise power consumption monitoring.

Is the firmware upgradeable?

Yes, firmware can be upgraded over the network for future product enhancements.

What is the warranty period?

Warranty information is not available.

What safety certifications does this PDU have?

The PDU has EAC, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, RCM, and VDE certifications.

Troubleshooting

PDU not powering on.

Check the power connection, ensure the power cord is securely plugged into both the PDU and the power source. Verify the circuit breaker on the PDU is not tripped.

Network connectivity issues.

Verify network cable connections, and confirm that the IP address and network settings are correctly configured. Check firewall settings if remote access is used.

Outlets not providing power.

Ensure the individual outlets are enabled through the web interface. Check if the devices connected to the outlets are functioning properly. Verify that the total power draw does not exceed the PDU's capacity.

High temperature alarms

Check the ambient temperature in the rack to ensure it is not exceeding 45°C. Clean any dust or debris from the unit and ensure proper ventilation within the rack.

Cannot access web interface

Confirm that you are using the correct IP address for the PDU and that your device is on the same network. Ensure your browser is not blocking access to the PDU's web interface.

Pros and Cons

Pros

  • Improved uptime through remote power cycling.
  • Precise power monitoring for better capacity planning.
  • Enhanced network management capabilities.
  • Flexible outlet grouping for efficient power sequencing.
  • Seamless integration with EcoStruxure IT.
  • High operating temperature up to 60C on select models

Cons

  • Requires careful rack configuration for proper installation.
  • Initial setup and configuration can be complex.
  • May require professional IT knowledge for optimal use.
  • Limited to 24 outlets on this specific model.
  • Wireless connectivity only available on select models.
  • Higher cost compared to basic PDUs

Setup, Compatibility & Care

  1. Rack Mounting: The PDU is designed for rack mounting. Ensure your rack has the necessary mounting rails and sufficient space. The unit is designed for 0U rack capacity, so be sure you have the appropriate vertical space.
  2. Power Connection: Connect the PDU to a reliable power source using the provided power cord. Ensure the power source meets the voltage and current requirements (200, 208, 230, 220-240 V, 32A max). The power plug is IEC 60309.
  3. Network Configuration: Connect the PDU to your network via the Gigabit Ethernet port. Configure the network settings (IP address, subnet mask, gateway) through the built-in web interface or the Network Management Card.
  4. Outlet Connections: Connect your devices to the appropriate outlets. Ensure the combined power draw of all connected devices does not exceed the PDU's load capacity (7360 W).
  5. Monitoring and Management: Access the PDU's web interface, SNMP, or Telnet to monitor power consumption, configure alerts, and manage outlets.
  6. Compatibility: This PDU is compatible with standard rack equipment. It works with C13 and C19 coupler outlets, and IEC 60309 power plugs. For enhanced cybersecurity, ensure that you use a strong password for all levels of user access.
  7. Care: Regularly inspect the PDU for dust and debris. Clean with a dry or slightly damp cloth. Avoid using harsh chemicals. Ensure that the operating environment is within the specified temperature (-5 - 45 °C) and humidity (0 - 95%) range.