Phoenix Contact Ethernet Plug - M12 Connector, Plug, Right Angle
Phoenix Contact Circular Connector, M12 Connector, Plug, IP67, SACC Series, Body Orientation: Stra...Phoenix Contact Circular Connector, M12 Connector, Plug, IP67, SACC Series, Body Orientation: Straight, MPN: 1429130. This product is an Ethernet Plug with a right-angle design and a silver finish, ideal for use in sensor and actuator data cables. It supports reliable connections in industrial and high-speed data communication applications. Additional technical information includes: 10 Gbit/s; Coding: X; Connection (components): Cut & Clip; Connection side A (sensors/actuators): M12 plug, right angle; Connection side B (sensors/actuators): Customisable; Connector cross-section (max.): 0.14 mm²; Connector standard: Ethernet; Connector type: Plug, right angle; Contact material: Copper alloy; Contact surface: Gold on nickel; Cross section (max.): 0.14 mm²; Factory colour: Silver; IP rating: IP67; Max. temperature: +80 °C; Min. temperature: -40 °C; No. of pins (RJ): 8P8C; Nominal current: 0.50 A; Nominal voltage: 50 V AC, 60 V DC; Thread type connection side: M12.
Phoenix Contact D-SUB Bus Connector SUBCON-PLUS-PROFIB/SC2 2708232£29.27 delivery£7.74Visit shop →
PHOENIX CONTACT 2313672, SUBCON-PLUS-PROFIB/90/IDC, D-SUB bus connector£29.14 delivery£12.82Visit shop →
Phoenix Contact Data Connector SACC-M12MSD-4Q SH PN 1554513£29.27 delivery£19.44Visit shop →
Phoenix Contact Data Connector SACC-M12FSD-4Q SH PN 1554526£29.27 delivery£23.66Visit shop →
Product Information
Full details
The Phoenix Contact 1429130 is a right-angle M12 Ethernet plug designed for reliable, high-speed data communication in industrial settings. It is ideal for sensor and actuator data cables, offering a secure IP67 rated connection. A key benefit is its innovative Cut & Clip connection method, allowing for quick assembly without wire stripping, though it requires specific tools for optimal performance.
All features
Model Part Number
1429130
Brand
Phoenix Contact
Extended Product Information
FAQs
What is the primary application for the Phoenix Contact 1429130?
This M12 Ethernet plug is designed for industrial applications, particularly for sensor and actuator data cables requiring high-speed (10 Gbit/s) and reliable connections in environments with dust and moisture.
What does IP67 rating mean for this connector?
An IP67 rating signifies that the connector is dust-tight and protected against the effects of temporary immersion in water (up to 1 meter for 30 minutes).
How does the Cut & Clip connection system work?
The Cut & Clip system allows for rapid termination of individual wires without the need for stripping. The connection mechanism pierces the wire insulation to make electrical contact, simplifying on-site assembly.
Can I use this connector with any Ethernet cable?
It is compatible with Ethernet cables having an external diameter between 4 mm and 8 mm, and conductor cross-sections up to 0.14 mm². The X-coding ensures it's used for Ethernet.
What is the maximum voltage and current this connector can handle?
The nominal voltage is 50 V AC / 60 V DC, and the nominal current is 0.50 A.
Is this connector suitable for extreme cold temperatures?
Yes, it is designed to operate reliably in temperatures as low as -40 °C.
What is the benefit of the right-angle design?
The right-angle design is beneficial for installations with limited space, allowing for more organized cable routing and reducing stress on the connection point by directing the cable away from obstacles.
Troubleshooting
Connection fails or shows intermittent signal loss.
Verify that the wires are correctly inserted into the Cut & Clip terminals and that the housing is fully closed. Ensure the cable diameter is within the specified range (4-8 mm) and the conductor cross-section does not exceed 0.14 mm². Check for any debris within the connector.
Connector does not provide a watertight seal.
Confirm that the cable gland is tightened properly around the cable jacket and that the connector housing is securely latched. Inspect the O-rings and sealing surfaces for any damage or debris.
Difficulty terminating wires using Cut & Clip.
Ensure you are using the correct tool if one is recommended for the Cut & Clip mechanism. Double-check that the wire insulation is properly seated within the terminal slot before closing the connector.
Connector is exposed to temperatures exceeding +80 °C.
Relocate the connection to an area within the specified operating temperature range or consider a connector with a higher temperature rating. Prolonged exposure to extreme heat can degrade materials and affect performance.
Pros and Cons
Pros
High-speed 10 Gbit/s Ethernet connectivity.
Robust IP67 rating for demanding environments.
Convenient and fast Cut & Clip termination.
Right-angle design aids in cable management.
Reliable signal transmission with 360° shielding.
Cons
Requires specific tools for optimal Cut & Clip termination.
Limited to 0.14 mm² conductor cross-section.
Customizable connection side B may require additional components.
Nominal current rating of 0.50 A may be a limitation for some power-over-Ethernet applications.
Maximum temperature of +80 °C might be restrictive in extremely high-temperature zones.
Setup, Compatibility & Care
Setup:
Prepare the cable end according to the Cut & Clip connection requirements. Ensure the correct wire preparation is followed for optimal contact.
Insert the prepared wires into the designated slots of the connector. The insulation displacement connection will pierce the wire insulation and make contact.
Close the connector housing to secure the connection. Ensure a firm click or closure to confirm.
Compatibility:
Ethernet Standard: Designed for Ethernet communication.
Connector Type: M12, X-coded, straight plug.
Cable Diameter: Compatible with external cable diameters from 4 mm to 8 mm.
Conductor Cross-Section: Supports conductors up to 0.14 mm².
Temperature Range: Operates reliably between -40 °C and +80 °C.
Care:
Clean the connector exterior with a dry or slightly damp cloth. Avoid using harsh chemicals or solvents.
Periodically inspect the connection for any signs of physical damage or corrosion, especially in harsh environments.
Ensure the connector cap is properly secured when not in use to maintain IP67 protection.