Catnic External Solid Wall Steel Lintel - CN71A

The Classic Box lintel for use in external solid wall applications. Manufactured from galvanised s...

Best current price£33.68from Materials Market Trading UK Ltd

All Offers

26 offers from £33.68 - £439.44

View price history by clicking the chart icon.

Materials Market Trading UK LtdCatnic Ang Single Leaf Angle Lintel 900Mm Silver
Free delivery in 1–3 days
£33.68
Visit shop
Brick SuperstoreCatnic Black Bsd100 Standard Duty Box Steel Lintel - 750Mm
£108.00 delivery
£40.75
Visit shop
Travis PerkinsCatnic External Solid Wall Single Leaf Steel Angle Lintel, 900mm
£30.00 delivery
£56.70
Visit shop
eBayCATNIC EXTERNAL SOLID WALL SINGLE LEAF ANGLE LINTEL 2700MM ANG2700
Free delivery in 1–3 days
£189.99
Visit shop

Product Information

Full details

The Catnic CN71A External Solid Wall Steel Lintel is specifically designed for builders and contractors constructing external solid walls, offering a robust and efficient solution for creating openings. Its key win is the combination of immediate load-bearing capability for wet masonry and comprehensive corrosion protection, which streamlines construction and ensures long-term durability. A primary caveat is its specific application for standard duty external solid walls, so it may not be suitable for all structural requirements or cavity wall constructions.

All features

Model Part NumberCN71A
BrandCatnic

Extended Product Information

FAQs

What type of wall is the Catnic CN71A Lintel designed for?

This lintel is specifically designed for use in external solid wall applications. It is not intended for cavity walls.

What is 'Duplex Corrosion Protection'?

Duplex Corrosion Protection refers to the lintel being manufactured from galvanised steel and then further enhanced with a powder-coated finish. This two-layer system provides superior resistance against corrosion and extends the product's lifespan.

Can I lay bricks on this lintel immediately after installation?

Yes, a key feature of this lintel is its design to carry a full load of wet masonry as soon as it is installed, allowing for immediate progress in construction.

What are the compatible outer leaf dimensions for this lintel?

The Catnic CN71A Lintel is suitable for outer leaves measuring between 200mm and 215mm.

What is the maximum load capacity and span for this standard duty lintel?

This standard duty lintel can carry loads up to 29kN and is suitable for spanning up to 2700mm, provided it has a minimum of 150mm end bearings at each side.

Does the lintel include insulation and a damp proof course (DPC)?

Yes, the Catnic CN71A Lintel features both integral insulation and a built-in DPC, contributing to thermal efficiency and moisture protection for the wall.

How does the 'box profile' benefit construction?

The box profile design provides inherent strength and rigidity, which helps the lintel resist twisting during the masonry build-up process, ensuring a more stable and straightforward installation.

Are different lengths of the CN71A Lintel available?

Yes, it is available in standard lengths up to 3000mm in 150mm increments, and also in 300mm increments between 3000mm and 3600mm, offering flexibility for various opening sizes.

Troubleshooting

Lintel appears to twist or sag during masonry build-up.

The box profile is designed to resist twisting. Ensure the lintel is installed perfectly level on a stable bed of mortar and that the minimum 150mm end bearings are fully supported. Overloading beyond its 29kN standard duty capacity or insufficient bearing can cause issues. Check the masonry above is evenly distributed.

Concern about long-term corrosion, especially in external applications.

The Catnic CN71A features Duplex Corrosion Protection, consisting of galvanised steel beneath a powder-coated finish. This dual-layer protection offers robust resistance to rust and environmental exposure. No specific ongoing treatment is generally needed. If the protective coating is significantly scratched or damaged before installation, it should be addressed to maintain full protection.

Lintel not supporting the expected load.

Verify that the total load (including masonry, floor loads, roof loads, etc.) does not exceed the lintel's standard duty capacity of 29kN. Also, confirm that the span is within the maximum specified (2700mm) and that the minimum 150mm end bearings are correctly implemented on stable masonry. Incorrect bearing length or excessive load are common causes of support issues.

Pros and Cons

Pros

  • Excellent corrosion resistance due to Duplex Protection (galvanised + powder coated).
  • Time-saving installation as it carries wet masonry immediately.
  • Integrated DPC and insulation simplify construction and enhance building performance.
  • Robust box profile resists twisting, ensuring stability during building.
  • Reduces the need for separate brickwork and insulation components.
  • Available in a wide range of standard lengths for versatile application.

Cons

  • Specifically designed for external solid walls, not suitable for cavity walls.
  • Standard duty only, may not be adequate for very heavy structural loads.
  • Requires specific outer leaf thickness (200-215mm) for optimal fit.
  • Maximum span limited to 2700mm for its full 29kN load capacity.
  • Weight varies significantly by length, requiring appropriate handling and lifting equipment for longer units.

Setup, Compatibility & Care

Setup Instructions

  1. Preparation: Ensure the opening is correctly sized and the supporting masonry below is level and strong enough to bear the lintel's weight plus the imposed load.
  2. Positioning: Place the lintel centrally over the opening, ensuring a minimum of 150mm end bearing on the supporting masonry at each end. This bearing is critical for load transfer.
  3. Levelling: Use a spirit level to ensure the lintel is perfectly horizontal. Adjust with mortar if necessary.
  4. Masonry Build-up: Begin laying masonry on top of the lintel immediately. The lintel is designed to carry a full load of wet masonry, eliminating the need for propping or curing time.
  5. Check Alignment: Continuously check the alignment as masonry is built up to ensure the lintel remains straight and plumb.

Compatibility

  • Wall Type: Specifically designed for external solid wall applications.
  • Outer Leaf: Compatible with outer leaves measuring 200mm to 215mm.
  • Masonry: Suitable for use with standard brick and block formats.
  • Load & Span: This is a standard duty lintel, capable of carrying loads up to 29kN over spans up to 2700mm, assuming 150mm end bearings.

Product Care

  • Pre-Installation Inspection: Before installation, visually inspect the lintel for any signs of damage to the galvanised and powder-coated finish. Any significant damage should be addressed as it could compromise corrosion protection.
  • Post-Installation: The Duplex Corrosion Protection provides long-term resistance. No special ongoing maintenance or treatment is typically required once installed within the wall structure. Ensure that the lintel is not exposed to harsh chemicals or abrasive cleaning agents, which could damage the protective coating.