The BLACK+DECKER Heat Alarm is designed for areas where smoke alarms may not be suitable, such as kitchens, garages, and attics, providing advanced heat detection to protect your home. Its key benefit is reliable heat sensing with reduced false alarms. A potential caveat is that it requires mains power, though it includes battery backup. This mains-powered heat detector features a 9V battery backup, easy installation, interlink capability, and BSI certification for safety.

All features

Model Part Number9V
BrandBLACK+DECKER

Extended Product Information

FAQs

Can this alarm detect smoke?

No, this is a heat alarm. It is designed to detect dangerous levels of heat, not smoke or carbon monoxide. For smoke detection, a separate smoke alarm is required.

How long does the 9V backup battery last?

The 9V alkaline battery serves as a backup for power outages and should be replaced annually or when a low battery warning is indicated. The main unit has a lifespan of 10 years.

What is the lifespan of this heat alarm?

The BLACK+DECKER Heat Alarm has a lifespan of up to 10 years from the date of manufacture. It is recommended to replace the unit after this period.

Can I link this alarm to other types of alarms?

This alarm can be interlinked with other compatible BLACK+DECKER alarms. Check the product manual for specific compatibility details.

Where is the best place to install a heat alarm?

Heat alarms are best suited for areas where smoke alarms might cause false alarms, such as kitchens, garages, workshops, and attics.

How do I silence the low battery warning chirp?

The low battery warning chirp will continue until the 9V battery is replaced with a new one.

Troubleshooting

Alarm is not sounding during test.

Check that the mains power is connected and the circuit breaker is on. Ensure the 9V battery is correctly installed and has sufficient charge. Verify the alarm is properly seated on its baseplate.

Low battery warning chirping.

Replace the 9V alkaline battery immediately with a new one. Ensure it is inserted with the correct polarity.

False alarms occurring frequently.

Ensure the alarm is installed in an appropriate location away from heat sources like radiators or cooking appliances. If installed in a kitchen, verify that steam or cooking fumes are not directly affecting the sensor. Clean the alarm casing with a vacuum cleaner.

Alarm has activated, but there is no visible fire.

Check the area for potential heat sources that may have triggered the alarm, such as overheating electrical equipment. The alarm memory feature will indicate which unit activated if interlinked.

Interlinked alarms are not communicating.

Verify that all interconnected alarms are of the same compatible model and are wired correctly according to the interlink instructions. Ensure all units have functioning batteries and mains power.

Pros and Cons

Pros

  • Specifically designed for areas unsuitable for smoke alarms.
  • Reduces false alarms from cooking, steam, or dust.
  • Provides continuous protection with mains power and battery backup.
  • Long 10-year lifespan reduces the need for frequent replacements.
  • Easy to install with a fast-fix baseplate.
  • BSI certified for guaranteed safety and quality.

Cons

  • Requires mains power connection, limiting placement options.
  • Does not detect smoke or carbon monoxide, only heat.
  • The 9V battery backup needs periodic replacement to maintain functionality.
  • Interlink capability requires purchasing additional compatible units.

Setup, Compatibility & Care Instructions

Setup:

  1. Ensure the mains power supply to the intended location is switched off at the breaker.
  2. Mount the fast-fix baseplate securely to the ceiling or wall using the provided screws.
  3. Wire the alarm to the mains supply according to local electrical regulations and the manufacturer's instructions.
  4. Insert a new 9V alkaline battery into the battery compartment.
  5. Attach the alarm to the baseplate.
  6. Restore mains power and test the alarm using the test button.

Compatibility:

This heat alarm is designed to be mains-powered and is compatible with standard household electrical wiring. It can be interlinked with other compatible BLACK+DECKER alarms for a connected system. It is not compatible with battery-only alarms or alarms from different manufacturers unless specified.

Care:

  • Regular Testing: Test the alarm weekly using the test button to ensure it is functioning correctly.
  • Battery Replacement: Replace the 9V backup battery annually or immediately when the low battery warning sounds.
  • Cleaning: Gently vacuum the alarm casing monthly to remove dust buildup. If necessary, wipe the exterior with a dry or slightly damp cloth. Avoid using cleaning sprays or solvents, as they can damage the unit.

Price History

DatePrice
Visit shop