Used to fill sealed systems from the mains cold water. Approved flexible hoses complete with check...Used to fill sealed systems from the mains cold water. Approved flexible hoses complete with check valves. Comply with water regulations and use WRAS approved components. This Altecnic CA-300606 ecofil plus standard filling loop is used to fill sealed systems from the mains cold water supplies. The loop comes complete with isolating valves and check valves and is designed to be connected to 15mm copper tube. An affordable product from a quality manufacturer. Features include 15mm connections, simple installation and use, stainless steel braided hose, isolating valve and check valve, and compliance with Water Regulation G24.1 and G24.2.
This guide is for anyone using the Altecnic Ecofil Plus Filling Loop to fill sealed heating systems. The primary benefit is its ability to safely and efficiently fill your system from the mains water supply, complying with water regulations. Note that proper installation and periodic checks are crucial for optimal performance and to prevent potential water damage.
All features
Model Part Number
CA-300606
Brand
Altecnic
Extended Product Information
FAQs
What is the purpose of the check valve?
The check valve prevents backflow, ensuring that water from your heating system cannot contaminate the mains water supply.
Where can I find the correct pressure for my heating system?
Refer to your boiler's manual for the recommended pressure levels. This information is usually found in the technical specifications.
What size pipe connections does this filling loop use?
This filling loop uses 15mm connections.
How often should I inspect the filling loop?
It is recommended to inspect the filling loop at least every six months and ideally with every boiler service.
What should I do if the filling loop is leaking?
Turn off the water supply immediately. Tighten the fittings and check the washers. If the leak persists, replace the filling loop.
Troubleshooting
The system isn't filling
Check that the isolating valve on the filling loop is open. Ensure your mains water supply is on and check for any blockages in the hose.
Leakage at the connections
Tighten the fittings. If the leakage persists, check the washers and replace them if necessary. Ensure the connections are properly sealed.
Pros and Cons
Pros
Easy to install
Complies with water regulations
Durable stainless steel braided hose
Includes isolating and check valves
Cons
Requires some plumbing knowledge for installation
May require additional fittings depending on your existing setup
Setup, Compatibility & Care
Installation: Connect the filling loop to the mains cold water supply and the heating system return. Ensure all connections are watertight.
Compatibility: This filling loop is compatible with sealed heating systems. It is designed for use with 15mm copper pipe connections.
Care: Regularly inspect the filling loop for leaks or damage. Check the check valve to ensure it is functioning correctly. Periodically operate the isolating valve to prevent it from seizing.