Interface Relay - Finder 4C Series

Professional interface relay module featuring a single changeover contact rated at 16A/250VAC with...

Best current price£38.77from eBay

One Offer

1 offer from £38.77

View price history by clicking the chart icon.

eBayInterface Relay Series 4C 1P 10A 230V 4C.P1.8.230.0060SPA
£13.20 delivery
£38.77
Visit shop

Product Information

Full details

This Finder 4C Series interface relay is designed for industrial automation professionals needing reliable signal conversion and control. Its primary benefit is its robust 16A switching capability and integrated features like LED indication and surge protection, simplifying complex wiring. A key consideration is its specific 230V AC coil voltage, requiring careful matching with control circuits. This module offers a compact, DIN-rail mountable solution with push-in terminals for efficient installation.

All features

Series4C Series
Model Part Number4C.P1.8.230.0060SPA
BrandFinder

Extended Product Information

FAQs

What is the primary function of this interface relay?

This interface relay acts as an electrically operated switch, allowing a low-power control signal (e.g., from a PLC) to control a higher-power circuit, such as a motor or lighting. It provides isolation between the control and load circuits.

Can I use this relay with a 12V DC control signal?

No, this relay has a 230V AC coil voltage and is specifically designed for AC control signals. Using a different voltage or DC signal will likely result in malfunction or damage.

What does the LED indicator signify?

The LED indicator lights up when the relay coil is energized by the 230V AC control voltage, confirming that the control signal is active and the relay is attempting to switch.

How do I connect wires to the push-in terminals?

Insert a solid conductor wire directly into the terminal opening. To release the wire, use a screwdriver to push down the release lever on the terminal.

What is the maximum load this relay can switch?

The relay has a single changeover contact rated for a maximum of 16A at 250VAC. Ensure your load does not exceed these ratings.

Is this relay suitable for outdoor use?

No, with an IP20 rating, it is designed for industrial enclosures and is not protected against water or significant dust ingress. It should be installed in a suitable protective cabinet.

What is the purpose of the integrated varistor?

The varistor is a surge protection device that absorbs voltage spikes that might occur on the control circuit, protecting the relay coil from damage and improving its reliability.

Troubleshooting

Relay does not energize when control voltage is applied.

Verify that the control voltage is exactly 230V AC and correctly connected to the coil terminals (A1/A2). Check if the LED indicator lights up. Ensure the coil circuit is not open.

Contacts do not switch load (no continuity when energized).

Confirm the coil is energized (LED is on). Check if the load wiring is correct and if the load itself is functional. Ensure the contact ratings are not exceeded.

Relay chatters or fails to de-energize.

Check for unstable or incorrect control voltage. Ensure the control voltage is within acceptable limits and that there are no residual voltages affecting the coil.

Overheating of the module.

Ensure the ambient temperature is within the specified range (-40°C to +50°C) and that the relay is not switching loads exceeding its 16A rating. Allow for adequate ventilation in the enclosure.

Pros and Cons

Pros

  • High switching capacity (16A) for versatile application.
  • Tool-free push-in terminals for quick and secure wiring.
  • Integrated LED status indicator for easy monitoring.
  • Built-in varistor protection enhances operational safety and lifespan.
  • Compact design with DIN-rail mounting simplifies panel integration.

Cons

  • Fixed 230V AC coil voltage limits application to compatible control systems.
  • Operating temperature range has limitations (+50°C maximum).
  • IP20 rating means it's not suitable for environments with significant dust or liquid ingress.
  • Single changeover contact may not be sufficient for all switching requirements.

Setup, Compatibility & Care

Setup:

  1. Ensure the control circuit voltage matches the relay's 230V AC coil specification.
  2. Mount the complete module (relay, socket, module, clip) onto a standard 35mm DIN rail.
  3. Connect the control voltage to the appropriate coil terminals (typically A1 and A2) using the push-in terminals.
  4. Wire the load to the common (3), normally open (2), and normally closed (1) contacts as required.

Compatibility:

  • Compatible with standard 35mm DIN rail mounting.
  • Requires a control voltage of 230V AC.
  • Suitable for use within ambient temperatures of -40°C to +50°C.

Care:

  • Keep the relay free from excessive dust and moisture.
  • Periodically check terminal connections for tightness, although the push-in design minimizes this need.
  • Avoid exceeding the maximum switching capacity (16A/250VAC).

Price History

DatePrice
Visit shop