TensCare L-CPT Leads - 2 Pack

Replacement lead wires for TensCare Perfect Range, Allura, Uniglo, BeautyMAX and NEW Touch TENS un...

Best current price£9.99from OnBuy.com

All Offers

2 offers from £9.99 - £12.61

View price history by clicking the chart icon.

OnBuy.comTenscare L-Cpt Leads For Perfect Range, Beauty Devices & Touch Tens (2 Pack)
£2.99 delivery
£9.99
Visit shop
AmazonTensCare Leadwires for NEW touch TENS, Perfect EMS, Perfect PFE and Uniglo - 2 x L-CPT (Eligible for VAT relief in the UK)
Free delivery in 1–3 days
£12.61
Visit shop

Product Information

Full details

This guide is for users of TensCare Perfect Range, Allura, Uniglo, BeautyMAX, and NEW Touch TENS units who need replacement lead wires. The key benefit is ensuring continued, reliable use of your TENS device for pain relief or muscle stimulation. A caveat is that compatibility with Touch TENS units requires checking the serial number. These lead wires feature round plastic connectors, are sold in a pack of two, and are designed for use with either two or four electrodes.

All features

Model Part NumberL-CPT
BrandTensCare

Extended Product Information

FAQs

Are these leads compatible with all TensCare TENS units?

These leads are compatible with TensCare Perfect Range, Allura, Uniglo, and BeautyMAX units. For NEW Touch TENS units, they are only compatible if the serial number is later than SVT120020001. Please check your unit's manual or serial number.

Can I use these leads with electrodes from another brand?

While the connectors are standard, it is highly recommended to use genuine TensCare leads with TensCare electrodes and units to ensure optimal performance and safety.

How many lead wires are included in this pack?

This pack contains two (2) replacement lead wires.

How do I connect the lead wires to my TENS unit?

The lead wires have round plastic connectors that plug into the designated ports on your TensCare TENS unit. Refer to your TENS unit's manual for specific port locations.

What should I do if my lead wires get wet?

If the lead wires get wet, immediately disconnect them from the TENS unit and electrode pads. Gently wipe them dry with a soft cloth. Do not use the TENS unit or the leads until they are completely dry.

How often should I replace my TENS lead wires?

Lead wires should be replaced if they show any signs of wear, such as fraying, cracking, or if you experience a loss of sensation or inconsistent performance. Regular inspection is advised.

Can I use one lead wire for a single electrode pad?

Yes, these lead wires can be used to connect a single electrode pad (for single-channel use with 2 electrodes total) or two lead wires can be used to connect two electrode pads for each channel (for dual-channel use with 4 electrodes total).

Troubleshooting

No sensation or intermittent sensation during TENS therapy.

Check that the lead wires are securely connected to both the TENS unit and the electrode pads. Ensure the electrode pads are properly positioned and making good contact with the skin. Inspect the lead wires for any visible damage or wear; replace if necessary.

TENS unit displays an error message related to connection.

This often indicates a problem with the lead wires or electrodes. Ensure the lead wires are fully inserted. Try using a different set of lead wires or a different pair of electrodes to isolate the issue.

One channel of the TENS unit is not working.

If using a dual-channel unit, check the lead wire connected to the non-working channel. Ensure it is securely plugged into the unit and the electrode pad. Try swapping the lead wires between channels to see if the problem follows the wire or stays with the channel.

Pros and Cons

Pros

  • Ensures uninterrupted TENS therapy sessions.
  • Compatible with a wide range of TensCare devices.
  • Provides a spare lead wire for convenience.
  • Supports flexible electrode configurations (2 or 4 electrodes).

Cons

  • Compatibility limited to specific Touch TENS serial numbers.
  • Requires replacement if damaged or worn.
  • Not compatible with TENS units from other brands.

Setup, Compatibility & Care

Setup:

  1. Ensure your TensCare TENS unit is turned OFF and unplugged.
  2. Identify the lead wire connectors. One end will plug into the TENS unit, and the other ends will connect to your electrode pads.
  3. Insert the round plastic connector end into the designated port on your TENS unit. For dual-channel units, you will use two lead wires, one for each channel.
  4. Connect the other end of the lead wires to your TENS electrode pads.

Compatibility:

  • TensCare Perfect Range, Allura, Uniglo, BeautyMAX units: Generally compatible.
  • TensCare NEW Touch TENS units: Compatible ONLY if the serial number is later than SVT120020001.
  • Always check your TENS unit's manual for specific lead wire requirements.

Care:

  • Store lead wires in a clean, dry place away from direct sunlight and extreme temperatures.
  • Avoid kinking or tightly wrapping the wires, as this can damage the internal conductors.
  • After each use, gently wipe the connectors with a dry cloth if necessary. Do not use water or solvents.
  • Inspect lead wires regularly for any signs of wear, fraying, or damage. Replace immediately if damage is found.

Price History

DatePrice
Visit shop