Marsh ENSIGN ULTRA 8 Person Sewage Treatment Plant - Pressure Switch Beacon Alarm - 250mm Riser - 200mm AVR Unit - Gravity Outlet

The Marsh ENSIGN ULTRA 8 person sewage treatment plant is a high-performance solution for undergro...

Best current price£12.49from Professional Building Supplies

All Offers

12 offers from £12.49 - £3,929.52

View price history by clicking the chart icon.

Professional Building SuppliesPbsl Group Standard Slatted Composite Cladding Angle Trim - 50Mm X 3.6Mtr Natural Edge Seal
Free delivery in 1–3 days
£12.49
Visit shop
PVC Cladding UKPbsl Group Standard Slatted Composite Cladding Angle Trim - 50Mm X 3.6Mtr Natural Edge Seal
Free delivery in 1–3 days
£12.49
Visit shop

Product Information

Full details

The Marsh ENSIGN ULTRA 8-person sewage treatment plant is an ideal high-performance solution for residential or small-scale commercial underground drainage systems where mains drainage is unavailable. Engineered for long-term reliability, it achieves an impressive 97% pollutant removal rate, though its installation requires professional excavation and specialized plumbing expertise due to the nature of the subterranean setup.

All features

Model Part NumberCSCAT50N36M
BrandMarsh

Extended Product Information

FAQs

How many people can this system support?

The Marsh ENSIGN ULTRA is rated for a capacity of up to 8 persons.

What is the structural guarantee period?

The structural components of the tank are covered by a 25-year guarantee.

Does the system need to be connected to the mains?

Yes, the compressor system requires a constant electrical power supply to function.

Can I install this myself?

No, professional installation is strongly advised as the unit requires specific excavation and connection to the drainage network to comply with building regulations.

What is the function of the riser?

The 250mm riser allows the access point of the tank to sit flush with the final ground level, even if the main body of the tank is buried deeper.

Troubleshooting

Beacon alarm is flashing red

Check the system for a pressure drop; the pressure switch has detected an air supply issue. Inspect the compressor and air lines for leaks or blockages.

Excessive noise or vibration

Verify that the 200mm AVR unit is installed correctly and that the compressor is sitting level on its mounting base.

System odor is noticeable

Ensure the system is correctly vented and that you are not disposing of harsh chemicals or antibacterial agents into the drains, which can kill the bacteria required for treatment.

Pros and Cons

Pros

  • High environmental performance with 97% pollutant removal
  • Quiet operation thanks to the dedicated acoustic vibration reduction unit
  • Comprehensive alarm system provides immediate notification of pressure drops
  • Long-term structural durability with a 25-year warranty

Cons

  • Requires professional installation due to underground complexity
  • Requires ongoing maintenance to ensure optimal biological function
  • Higher initial setup costs compared to basic septic systems

Setup, Compatibility & Care

Installation must be performed by qualified drainage specialists. The unit is designed for gravity outlet discharge. It is essential to ensure that the surrounding ground conditions are suitable for the tank excavation and that the riser is correctly sealed to prevent groundwater ingress. For care, keep the compressor housing clear of obstructions to maintain airflow. Regularly check the alarm beacon to ensure it remains functional. Routine desludging intervals should be adhered to according to manufacturer specifications to prevent solids from building up in the primary chamber.