Eaton 5PX G2 - UPS - 5PX2200IRTNG2BS

The new Eaton 5PX Gen2 UPS provides Enterprise Networks and Edge IT equipment with best-in-class l...

Best current price£709.46from PCHUB.UK

All Offers

54 offers from £709.46 - £2,244.97

View price history by clicking the chart icon.

PCHUB.UKEaton 5Px1000irt2ug2bs Uninterruptible Power Supply (Ups) Line-Interac
Free delivery in 1–3 days
£709.46
Visit shop
GamingKitEaton 5Px1000irt2ug2bs Uninterruptible Power Supply (Ups) Line-Interac
Free delivery in 1–3 days
£851.35
Visit shop
PcNova.co.ukEaton 5Px1000irt2ug2bs Uninterruptible Power Supply (Ups) Line-Interac
Free delivery in 1–3 days
£851.45
Visit shop
eBayEaton Ups 1.1 Kva / 770 W Line Interactive Tower Eaton 5PX1000IRT2UG2BS. Ups Top
Free delivery in 1–3 days
£910.55
Visit shop
Laptops Direct (BID)Eaton 5Px G2 - Ups (Rack-Mountable / External) - Ac 150 - 294 V - 1500 Watt - 1500 Va - 1-Phase - 9 Ah - Rs-232 Black,Silver, Laptops Direct - 5PX1500IRT2UG2BS
£6.95 delivery
£1,074.97
Visit shop

Product Information

Full details

This guide is for IT professionals and system administrators seeking reliable power protection for their critical equipment. The Eaton 5PX Gen2 UPS provides line-interactive backup power, ensuring your servers and network devices stay online during outages. A potential drawback is the initial setup, which requires careful configuration for optimal performance. Key features include a user-friendly LCD interface, remote monitoring capabilities, and extended runtime options.

All features

Model Part Number5PX2200IRTNG2BS
BrandEaton

Extended Product Information

FAQs

What is the lifespan of the batteries?

The batteries typically last 3-5 years under normal operating conditions. Battery life depends on usage and environmental factors.

How do I replace the batteries?

Refer to the user manual for battery replacement instructions. Replacement usually involves removing the front panel and swapping the battery modules.

Can I connect devices that draw more than 2200W?

No, you should not connect devices that exceed the UPS's output capacity of 2200W. Doing so will overload the UPS and potentially cause it to shut down.

How do I monitor the UPS remotely?

Use the network management card (if included) to monitor the UPS via a web browser or network management software.

What is the difference between line-interactive and online UPS?

Line-interactive UPS provides power conditioning and backup power. Online UPS provides continuous power conditioning and zero transfer time in case of a power outage, ideal for sensitive equipment. The Eaton 5PX Gen2 is line-interactive.

What is the meaning of the error code on the LCD?

Refer to the user manual for a list of error codes and their meanings. The manual will provide troubleshooting steps for each error.

How often should I test the UPS?

It is recommended to test the UPS at least once a month to ensure it is functioning correctly. Most UPS units have an automatic test feature.

Troubleshooting

UPS not powering on.

Check the power connection to the wall outlet and the UPS. Ensure the power switch on the UPS is turned on.

UPS beeping continuously.

Check the LCD display for error messages. The UPS may be overloaded or the battery may need replacing.

UPS not providing backup power.

Check the battery connections. If the battery is old, it may need to be replaced.

LCD display not working.

Ensure the UPS is receiving power. Try resetting the UPS by turning it off and on.

Network monitoring not working.

Verify network settings and connectivity. Ensure the network card is properly configured and connected to the network.

Pros and Cons

Pros

  • Provides reliable backup power, minimizing downtime.
  • Offers remote monitoring and management capabilities.
  • Features a user-friendly LCD interface for easy operation.
  • Provides multiple outlet types for versatile device connections.
  • Offers high efficiency, reducing energy consumption and costs.
  • Supports extended battery modules for longer runtimes.

Cons

  • Initial setup and configuration may require technical expertise.
  • Extended battery modules add to the overall cost.
  • Requires regular battery maintenance.
  • The unit itself has a considerable weight.
  • Can be noisy during battery testing.
  • Limited to a specific number of outlets.

Setup, Compatibility & Care

  1. Installation:
  • Unpack the UPS and rack-mount or place it in tower configuration.
  • Connect the input power cable (C20) to a dedicated power source.
  • Connect your devices to the appropriate output outlets (C13/C19).
  1. Configuration:
  • Use the LCD interface to configure the UPS settings, such as input voltage, output voltage, and sensitivity.
  • Set up network monitoring via the network card (if included) for remote management.
  1. Compatibility:
  • Compatible with a wide range of devices, including servers, network equipment, and VoIP systems.
  • Ensure the total power draw of connected devices does not exceed the UPS's output capacity (2200W/2.2kVA).
  1. Care & Maintenance:
  • Perform regular battery tests via the LCD panel or the remote management software.
  • Check the battery health and replace batteries every 3-5 years (depending on usage and environmental conditions).
  • Keep the UPS in a clean, well-ventilated environment.
  • Do not block the vents on the unit. Wipe it down with a dry cloth.

Similar items

Price History

DatePrice
Visit shop