PowerWalker VFI 3000 AT UK - PowerWalker - 10122188

The PowerWalker VFI AT is an Online UPS series with double conversion technology, designed to safe...

Best current price£332.15from PCHUB.UK

All Offers

2 offers from £332.15 - £398.58

View price history by clicking the chart icon.

PCHUB.UKPowerwalker Vfi 3000 At Uk Uninterruptible Power Supply (Ups) Double-C
Free delivery in 1–3 days
£332.15
Visit shop
GamingKitPowerwalker Vfi 3000 At Uk Uninterruptible Power Supply (Ups) Double-C
Free delivery in 1–3 days
£398.58
Visit shop

Product Information

Full details

This guide helps users of the PowerWalker VFI 3000 AT UK understand and effectively utilize its features. Designed for professionals, this Online UPS with double conversion technology safeguards critical equipment from power disruptions, providing reliable backup power. While offering robust protection, users should be aware of the 3.5-minute backup time at full load. Key features include double-conversion technology, a 3 kVA/2700 W capacity, and multiple outlet types for broad compatibility.

All features

Model Part Number10122188
BrandPowerWalker

Extended Product Information

FAQs

How long does the battery last?

At full load, the typical backup time is 3.5 minutes. At half load, it's about 11 minutes. The backup time can be extended with external battery packs.

What type of outlets does the UPS have?

The UPS has Type G (BS 1363) outlets.

How do I check the battery status?

The LCD display provides the battery status, including charge level and any potential issues.

How do I connect external batteries?

The UPS supports external battery packs. Consult the user manual for specific instructions on connecting external batteries.

What is the warranty period?

Warranty details are not specified in the given data, please refer to the product documentation or contact the seller.

What is the surge energy rating?

The surge energy rating is 156 J.

What is the input power factor?

The input power factor is 0.99.

How long does it take to recharge the battery?

The battery recharge time is 4 hours.

Troubleshooting

UPS not turning on.

Check the power connection and ensure the outlet is working. Also, verify that the UPS is switched on and the internal circuit breaker hasn't tripped.

UPS beeping continuously.

Check the LCD display for error messages. The battery may need replacing or there might be an overload condition. Reduce the load on the UPS or replace the battery.

UPS providing limited backup time.

The battery may need to be replaced. Ensure the UPS is fully charged. Reduce the load on the UPS.

Equipment not receiving power during an outage.

Check the connections to the UPS. Ensure the UPS is switched on and the internal circuit breaker hasn't tripped.

LCD display not working.

Check the power supply to the UPS. Try to reset the UPS by turning it off and on again. If it is still not working contact support.

Pros and Cons

Pros

  • Provides reliable power protection with double-conversion technology.
  • Offers a high power capacity suitable for professional equipment.
  • Features multiple outlet types for broad device compatibility.
  • Provides clear status information via an LCD display.
  • Supports external batteries for extended backup time.
  • Delivers a pure sine wave output for compatibility with sensitive equipment.

Cons

  • Limited backup time at full load (3.5 minutes).
  • Requires professional installation for optimal performance.
  • May require additional accessories (external batteries, communication cards) for extended functionality.
  • Heavier than standard UPS units due to the internal components and batteries.
  • Can be more expensive than some other UPS options.

Setup, Compatibility & Care

Setup

  1. Placement: Place the UPS in a well-ventilated area, away from direct sunlight, moisture, and extreme temperatures.
  2. Connections: Connect the equipment to be protected to the AC outlets on the back of the UPS.
  3. Power Input: Plug the UPS power cord into a grounded AC outlet.
  4. Power On: Press the power button on the front panel to turn on the UPS.
  5. Configuration: Use the LCD display and the buttons on the front panel to configure the UPS settings.

Compatibility

The PowerWalker VFI 3000 AT UK is compatible with:

  • Devices with Type G (BS 1363) plugs.
  • A wide range of electronic devices, servers, and network equipment.
  • Operating systems that support UPS monitoring via USB or RS-232.

Care

  • Cleaning: Clean the exterior of the UPS with a dry cloth.
  • Ventilation: Ensure that the ventilation openings on the UPS are not blocked.
  • Battery Maintenance: Check the battery regularly and replace it if necessary. Refer to the manufacturer's recommendations.
  • Environmental Considerations: Operate the UPS within the specified temperature and humidity ranges (0 - 40 °C, 20 - 90% relative humidity).

Price History

DatePrice
Visit shop