Suitable for use with potable water in secondary hot water systems, this maintenance-free circulat...Suitable for use with potable water in secondary hot water systems, this maintenance-free circulator pump delivers high efficiency and a high starting torque, with an automatic de-blocking function. An LED display shows the energy consumption, flow rate and pressure, as well as any error codes. This pump is Reg4-compliant. A thermal insulation shell is supplied. * Selectable control modes - for simple setup and adjustment * Integrated motor protection - for long-lasting reliability * Manual venting function - for venting the rotor chamber * Stainless steel housing - for durability * Wilo-Connector - for a quick electrical connection without tools Wilo Yonos Pico Circulating Pump 25/0.5-6-130 230V in Green Steel. The Wilo Yonos PICO-Z is a low noise, compact pump suitable to be installed into tight spaces in residential or light commercial buildings. A secondary hot water pump for reliable performance, low energy consumption and long service life. This is a direct replacement for the Wilo SB30 bronze secondary hot water pump. Features & Benefits: Quick and easy installation. Thermal insulation shell included. Power Consumption only 4 - 40 Watts. Flow adjustment. Pressure adjustment. Plug & play wiring with the Wilo connection plug – no tools needed! Automatic and manual venting & deblocking modes. Manufactured in a climate neutral factory. 130mm port to port dimension allowing an easy replacement. LED display shows flow, head pressure, power consumption in Watts, and error codes. Pipe Work Connection Diameter: 25mm.
This Wilo Yonos Pico circulating pump is ideal for secondary hot water systems in residential and light commercial buildings, offering a maintenance-free, high-efficiency solution. Its key benefit is reliable performance with low energy consumption and a long service life, although its compact size might require careful installation planning in some existing setups. Key features include selectable control modes, integrated motor protection, automatic and manual venting, a durable stainless steel housing, and a quick, tool-free electrical connection via the Wilo-Connector.
All features
Model Part Number
4255416
Brand
Wilo
Extended Product Information
FAQs
What is a secondary hot water system?
A secondary hot water system, also known as a hot water recirculation system, keeps hot water circulating through the pipes to ensure hot water is available quickly at the tap, rather than having to run the water until it heats up.
Is this pump suitable for domestic hot water systems?
Yes, this Wilo Yonos Pico pump is specifically designed for use with potable water in secondary hot water systems in residential and light commercial buildings.
How do I connect the pump electrically without tools?
The pump features a Wilo-Connector, a plug-and-play system designed for quick electrical connections without the need for any tools. Simply push the connector into place.
What does the LED display show?
The LED display provides real-time information including current energy consumption in Watts, flow rate, head pressure, and any diagnostic error codes.
How often does this pump require maintenance?
This pump is designed to be maintenance-free, thanks to features like automatic de-blocking and integrated motor protection. Regular system checks are recommended, but the pump itself requires minimal direct upkeep.
What is the benefit of the stainless steel housing?
The stainless steel housing provides durability and resistance to corrosion, ensuring a long service life for the pump, especially in water systems.
Can I adjust the pump's performance?
Yes, the pump features selectable control modes that allow for adjustment of flow and pressure to suit the specific requirements of your heating system.
Troubleshooting
Pump is not running
Check the electrical connection and ensure the power supply is active. Verify that the circuit breaker has not tripped. Ensure the pump is not blocked by debris by checking for any error codes on the LED display.
Low flow rate or no hot water circulation
Check if the pump is correctly installed and running. Ensure the system is properly vented using the manual vent function. Inspect the system for any blockages or closed valves. Verify that the selected control mode is appropriate for the system's needs.
Unusual noise from the pump
Air in the system can cause noise; use the manual venting function. Ensure the pump is securely mounted to the pipework to minimize vibration. Check for any foreign objects that might be interfering with the impeller.
Error code displayed
Consult the pump's operational manual for a specific breakdown of error codes and their corresponding solutions. Common codes may relate to electrical faults, blockages, or temperature issues.
Pros and Cons
Pros
Energy-efficient operation with low power consumption.
Durable stainless steel construction ensures longevity.
Clear LED display for monitoring performance and status.
Compact design suitable for tight spaces.
Cons
May require specific planning for installation in very confined existing spaces due to its compact nature.
Primarily designed for secondary hot water systems, may not be suitable for all applications.
Advanced users might prefer more granular control options beyond the selectable modes.
Setup, Compatibility & Care
Setup:
Electrical Connection: Utilize the provided Wilo-Connector for a quick, tool-free electrical connection. Ensure the power supply matches the pump's requirements (230V).
Positioning: Install the pump in a location that allows for easy access for any future maintenance and ensure it is correctly oriented according to the installation manual.
Venting: Before initial operation, use the manual venting function to purge air from the rotor chamber.
Control Mode Selection: Choose the appropriate control mode (e.g., proportional pressure, constant pressure, or constant speed) based on system requirements using the pump's interface.
Compatibility:
Potable Water: Suitable for use with potable water in secondary hot water systems.
Pipe Work: Designed for pipe work with a 25mm connection diameter and has a 130mm port-to-port dimension for easy integration into existing plumbing.
System Type: Specifically designed for secondary hot water recirculation.
Care:
Cleaning: The pump requires minimal maintenance. Clean the exterior with a damp cloth if necessary. Avoid harsh chemicals.
System Checks: Periodically check the system for leaks or unusual noises. The LED display will indicate any error codes that might require attention.
Venting: While the pump has automatic de-blocking, manual venting can be performed periodically if system performance seems reduced.