Calder Industrial Code 4 Lead Flashing - 390mm x 6m

Lead roof flashing provides a long-term watertight roofing option and lasts three times longer tha...

Best current price£250.56from Travis Perkins

One Offer

1 offer from £250.56

View price history by clicking the chart icon.

Travis PerkinsCalder Industrial Code 4 Lead Flashing 390mm x 6000mm
Free delivery in 1–3 days
£250.56
Visit shop

Product Information

Full details

This guide is for roofers, builders, and DIY enthusiasts seeking a durable and environmentally friendly solution for roof waterproofing. The Calder Industrial Code 4 Lead Flashing offers exceptional longevity and weather resistance, lasting up to three times longer than man-made alternatives. While its initial cost is comparable to alternatives when adhesives are considered, it requires no additional fixings. This product provides a reliable, long-term watertight seal for various roofing applications.

All features

Model Part Number40022439
BrandCalder

Extended Product Information

FAQs

How long does lead flashing typically last?

Calder Industrial Code 4 Lead Flashing is designed to last up to 100 years, significantly outlasting most man-made alternatives which typically last around 30 years.

Does lead flashing require adhesives or sealants?

No, lead flashing does not require adhesives or sealants. It is installed by dressing and bossing it into place, often with mechanical fixings or interlocking details.

What is patination oil and why is it needed?

Patination oil is a protective coating applied after installation. It helps to prevent the formation of white lead carbonate, which can cause unsightly white streaks and stains on the lead surface and surrounding materials.

Is lead a sustainable material for construction?

Yes, lead is a continuously recyclable material. While extraction has environmental impacts, its longevity and recyclability contribute to its sustainable profile in construction.

Can lead flashing be used for decorative purposes?

Yes, lead is renowned for its suitability for decorative flashing and can be expertly bossed or dressed to create aesthetically pleasing architectural features.

Where can I find installation guides?

Installation guides for cover flashing and step flashing are available at http://www.calderlead.co.uk/downloads/. Video resources can also be found at http://youtu.be/eS4CfS-K0PE and http://youtu.be/GBtvHif6bTE.

What are the advantages of lead over synthetic flashing materials?

Lead offers superior longevity, better resistance to extreme weather, requires no adhesives, is more easily shaped for complex details, and is environmentally friendly due to its recyclability.

Troubleshooting

White powdery residue forming on lead surface

This is likely white lead carbonate. Ensure patination oil was applied correctly after installation. If significant, cleaning may be required, followed by reapplication of patination oil.

Water pooling or slow drainage around flashing

Check that the lead has been dressed correctly to facilitate water runoff and that no debris is obstructing the intended drainage path.

Difficulty shaping lead for complex angles

Ensure the lead has not been over-worked or repeatedly folded, which can cause work-hardening. Gentle heating can sometimes improve malleability, or consult professional installation guides for specific techniques.

Pros and Cons

Pros

  • Extremely long lifespan (up to 100 years)
  • Superior weather resistance and watertightness
  • Environmentally sound due to recyclability
  • Cost-effective when considering longevity and lack of additional materials
  • Easy to work with and install in diverse conditions
  • Low maintenance requirements

Cons

  • Requires specialized knowledge for optimal bossing and dressing
  • Can be heavier than some synthetic alternatives
  • Environmental concerns exist regarding lead extraction and disposal, despite recyclability
  • Requires coating with patination oil after installation
  • May not be suitable for all modern roofing systems without specific detailing

Setup, Compatibility & Care Instructions

Installation: Lead sheet flashing is designed for easy installation. It can be quickly dressed and shaped on-site to fit the specific contours of the roof or structure. No adhesives or additional fixing materials are required, as lead can be mechanically fixed or dressed to interlock. For detailed guidance on installation techniques such as cover flashing and step flashing, refer to guides available at http://www.calderlead.co.uk/downloads/ or the video resources at http://youtu.be/eS4CfS-K0PE and http://youtu.be/GBtvHif6bTE.

Compatibility: This lead flashing is compatible with most traditional roofing materials, including slate, tile, and asphalt. It is also suitable for sealing gaps around various building elements like doors, windows, and penetrations.

Care: After installation, all lead sheet should be coated with patination oil. This helps to prevent the formation of white lead carbonate, which can streak and stain surrounding materials. Regular inspection is not typically required due to the material's longevity, but periodic visual checks for any dislodged sections or significant damage after severe weather events are advisable.