Hensel Junction Box - DE 9321

HENSEL DE Series White Polycarbonate Junction Box, IP55, 50 x 88 x 88mm. This junction box is halo...

Best current price£4.56from Rapid Online - Rapid Electronics Ltd.

All Offers

15 offers from £4.56 - £76.48

View price history by clicking the chart icon.

Rapid Online - Rapid Electronics Ltd.Hensel 62000269 Junction Box Halogen-Free 88 x 88 mm Thermoplastic
Free delivery in 1–3 days
£4.56
Visit shop
Tameson UKHensel Grey Enycase Surface Mounted Wall/Ceiling Box - Dk0200g
Free delivery in 1–3 days
£6.08
Visit shop
eBayHENSEL 62000082 Enclosure
£13.20 delivery
£30.46
Visit shop

Product Information

Full details

The Hensel DE Series DE 9321 is a white polycarbonate junction box designed for secure electrical connections in demanding environments. It offers IP55 protection and halogen-free construction, making it ideal for applications requiring flame retardant materials. While it provides robust protection, users should note its specific dimensions and potential limitations with larger conductor cross-sections.

All features

Model Part NumberDE 9321
BrandHENSEL

Extended Product Information

FAQs

What is the maximum conductor size this box can accommodate?

This junction box is designed for a maximum conductor cross-section of 2.5mm².

Is this junction box suitable for outdoor use?

Yes, with an IP55 rating, it offers protection against dust and water jets, making it suitable for many outdoor applications. Ensure proper sealing of cable entries.

What does 'halogen-free' mean for this product?

Halogen-free means the plastic material does not contain halogens (like chlorine or bromine). This is important for fire safety, as halogen-free materials tend to produce less toxic smoke when burned compared to traditional plastics.

How many cable entries does the box have?

The box is equipped with 10 potential inlets using seal membranes for cable entry.

Can I use this box for high-temperature applications?

The working temperature range for this box is -25°C to 40°C. It is not suitable for high-temperature environments beyond this range.

How is the box sealed?

The box is sealed by its cover, which screws onto the base, and by the seal membranes at the cable entry points. Proper installation is crucial for maintaining the IP rating.

What mounting method is recommended?

This is a surface-mounted box designed for wall or ceiling mounting. Use appropriate fasteners for your mounting surface.

Troubleshooting

Box cover does not seal properly.

Ensure the sealing gasket is clean and free of debris. Check that the cover is seated correctly and that all screws are tightened evenly in a star pattern.

Difficulty piercing seal membrane.

Use a sharp, pointed tool (e.g., a calibrated piercing tool or a sturdy screwdriver) to cleanly pierce the membrane at the desired location. Ensure you are piercing the correct pre-scored point.

Condensation inside the box.

Ensure cables are properly sealed at the entry points to prevent moisture ingress. The working temperature range should be considered; extreme temperature fluctuations can cause condensation. Ensure proper ventilation if applicable and permitted by code.

Box feels loose after mounting.

Verify that the mounting screws are appropriate for the wall/ceiling material and are fully tightened. Ensure the mounting surface is flat and stable.

Pros and Cons

Pros

  • Durable and halogen-free construction for safety.
  • Good environmental protection with IP55 rating.
  • Compact size suitable for limited spaces.
  • Versatile with multiple entry points.
  • Sealable for added security and protection.

Cons

  • Limited to a maximum conductor cross-section of 2.5mm².
  • Working temperature range is relatively narrow.
  • May require specific tools for membrane seal preparation.
  • Square shape might not fit all installation constraints.

Setup, Compatibility & Care

Setup:

  1. Mounting: Securely attach the box to a clean, flat wall or ceiling surface using appropriate screws (not included). Ensure the mounting surface is capable of supporting the box and its contents.
  2. Cable Entry: Identify the desired cable entry points. The box features 10 seal membrane entries. Carefully pierce the membrane at the desired location for cable insertion. Ensure a snug fit around the cable to maintain the IP rating.
  3. Wiring: Install electrical connections within the box according to local electrical codes and safety standards. Ensure conductors do not exceed the maximum cross-section of 2.5mm².
  4. Closing: Securely attach the cover using the provided screws. Ensure the seal is properly seated to maintain environmental protection.

Compatibility:

  • Suitable for use with conductors up to a maximum cross-section of 2.5mm².
  • Designed for surface mounting on walls and ceilings.
  • Compatible with standard electrical wiring practices.

Care:

  • Cleaning: Clean the exterior of the junction box with a dry or slightly damp cloth. Avoid using abrasive cleaners or solvents that could damage the polycarbonate.
  • Inspection: Periodically inspect the box for any signs of damage, wear, or compromised seals, especially if used in harsh environments. Ensure all screws are tightened.
  • Maintenance: If the seal membranes are pierced, ensure they remain intact or are replaced if damaged to maintain IP rating.

Price History

DatePrice