Biasi Control Panel PCB - Hanicks Bi2195113

This control panel PCB is compatible with various Biasi appliance models, including Activ A 12OV (...

Best current price£70.00from OnBuy.com

One Offer

1 offer from £70.00

View price history by clicking the chart icon.

OnBuy.comBiasi Active/Advance Plus 12/15/16/20/25/30/35 Kw Control Panel Pcb Bi2195113 8023585863138
Free delivery in 1–3 days
£70.00
Visit shop

Product Information

Full details

This Hanicks Bi2195113 control panel PCB is designed for Biasi appliances, offering a direct replacement to restore appliance functionality. It is ideal for technicians or homeowners needing to repair their Biasi heating system. A key benefit is its specific compatibility with certain Biasi models, ensuring a precise fit. However, it is crucial to confirm your appliance's exact model number before purchase, as incorrect installation can lead to further issues.

All features

Model Part NumberBi2195113
BrandHanicks

Extended Product Information

FAQs

How do I know if I need to replace my Biasi control panel PCB?

Symptoms often include the appliance not turning on, error codes displayed on the interface, intermittent operation, or failure to respond to commands. If these issues occur, a faulty PCB is a common cause, but professional diagnosis is recommended.

What Biasi appliance models are compatible with the Hanicks Bi2195113 PCB?

This PCB is compatible with Biasi Activ A 12OV (GC No. 41-583-14), Activ A 15OV (GC No. 41-583-15), Activ A 20OV (GC No. 41-583-16), Activ A 25OV (GC No. 41-583-17), and other similar models. Always confirm your specific appliance's GC number.

Can I install the control panel PCB myself?

Installation of control panel PCBs requires specific technical knowledge and should be performed by a qualified heating engineer or appliance technician to avoid damage to the component or the appliance, and for safety reasons.

What is the manufacturer part number for this control panel?

The manufacturer part number is Bi2195113.

What should I do if the appliance still doesn't work after replacing the PCB?

Ensure all wiring is correctly and securely connected. Verify that the correct PCB model was installed and that the power supply is adequate. If problems persist, there may be an issue with another component in the appliance, and a professional diagnosis is needed.

Where can I find the GC number for my Biasi appliance?

The GC number (Gas Council number) is typically found on the appliance's rating plate, often located on the inside of the appliance casing or on the back of the unit.

Troubleshooting

Appliance does not power on after PCB replacement

Double-check all wiring connections to the new PCB. Ensure the power supply is correctly connected to the appliance and that the fuse or circuit breaker is functional. Verify the correct PCB model was installed.

Appliance shows error codes related to control

Consult the appliance's user manual for the specific error code. If the code persists after PCB replacement, there might be an issue with another component or a faulty connection. Re-verify wiring and consult a professional.

Intermittent appliance operation

Ensure all connections are secure and not loose. Check for any physical damage to the PCB or its components. If the issue continues, a professional diagnosis of other appliance systems may be required.

Incorrect diagnostic lights or LEDs on the panel

Refer to the appliance's service manual for the meaning of diagnostic lights. Ensure the PCB is seated correctly and all connectors are firm. If the problem persists, the new PCB may be faulty or another component is causing the issue.

Pros and Cons

Pros

  • Ensures proper control and operation of compatible Biasi appliances.
  • Designed for a precise fit in specific Biasi models.
  • Helps extend the lifespan of your Biasi appliance by replacing a faulty control board.
  • Direct replacement simplifies the repair for qualified technicians.

Cons

  • Requires precise model identification for compatibility.
  • Installation may require professional knowledge of appliance repair.
  • Not a universal part; limited to specific Biasi models.
  • Potential for damage if installed incorrectly.

Setup, Compatibility & Care

Compatibility Check:

Before installation, verify that your Biasi appliance model is listed as compatible with the Hanicks Bi2195113 PCB. Consult your appliance's manual or contact Biasi support with your appliance's GC number to confirm. This PCB is confirmed for models including Activ A 12OV (GC No. 41-583-14), Activ A 15OV (GC No. 41-583-15), Activ A 20OV (GC No. 41-583-16), and Activ A 25OV (GC No. 41-583-17).

Installation:

Installation of a control panel PCB should only be performed by a qualified and experienced heating engineer or appliance technician.

  1. Safety First: Ensure the appliance is completely isolated from the power supply and any gas or water lines are safely shut off.
  2. Access: Carefully open the appliance casing to access the existing control panel.
  3. Removal: Document the wiring connections before disconnecting any wires from the old PCB. Carefully remove the old PCB.
  4. Installation: Connect the wiring to the new Hanicks Bi2195113 PCB according to the documented connections or the new PCB's labelling.
  5. Securing: Mount the new PCB securely in its designated position.
  6. Reassembly: Reassemble the appliance casing.
  7. Testing: Reconnect power and test the appliance thoroughly to ensure it operates correctly.

Care:

This component is an internal electronic part and requires no regular user care. Protect it from dust and moisture during installation. Ensure the appliance itself is maintained according to manufacturer guidelines to prevent issues that could indirectly affect the PCB.

Price History

DatePrice
Visit shop