Lowenergie Battery Temperature Sensor Cable - TS-R
This is a remote temperature sensor (TS-R) designed for EPEver MPPT solar charge controllers, spec...This is a remote temperature sensor (TS-R) designed for EPEver MPPT solar charge controllers, specifically the Tracer and Triron series. It accurately senses battery temperature to optimize charging efficiency and maximize the performance of your solar power system. Compatible with EPEver Controllers: TRACER-AN Series and Etracer Series (e.g., Etracer-3414, Etracer-4415, Etracer-6414).
The Lowenergie TS-R is a remote temperature sensor designed for EPEver MPPT solar charge controllers, primarily the Tracer and Triron series. It accurately measures battery temperature to optimize charging cycles, enhancing overall solar system efficiency and performance. While crucial for battery health and longevity, it requires a compatible EPEver controller to function.
All features
Model Part Number
TS-R
Brand
Lowenergie
Extended Product Information
FAQs
What is the operating temperature range for the TS-R sensor?
The TS-R is designed to operate within typical ambient temperature ranges encountered by solar power systems, usually from -10°C to +70°C. Refer to the specific EPEver charge controller manual for precise operational limits.
Can I use the TS-R with charge controllers from other brands?
No, the TS-R is specifically designed and calibrated for use with compatible EPEver MPPT solar charge controllers, such as the Tracer-AN and Etracer series. Using it with other brands may result in incorrect readings or system malfunctions.
How does temperature compensation work?
Temperature compensation adjusts the charging voltage based on battery temperature. When temperatures rise, charging voltage is lowered to prevent overcharging. When temperatures fall, charging voltage is increased to ensure adequate charging in colder conditions.
Do I need to calibrate the TS-R sensor?
No, the TS-R sensor is factory calibrated and does not require user calibration. It is designed for plug-and-play operation with compatible EPEver controllers.
What is the length of the TS-R cable?
The standard cable length for the TS-R is typically around 3 meters (approximately 9.8 feet), providing sufficient reach for most installations. Please check the product specifications for the exact length.
Where is the best place to position the sensor for accurate readings?
The sensor should be placed in contact with the battery casing or in close proximity to the battery bank, in an area that reflects the average temperature experienced by the batteries. Avoid direct sunlight or areas with significant artificial heating/cooling not related to battery operation.
Troubleshooting
Controller does not recognize the temperature sensor
Ensure the sensor is securely plugged into the correct port on the charge controller. Verify that your charge controller model is listed as compatible with the TS-R. Check the sensor cable for damage.
Inaccurate battery temperature readings
Ensure the sensor probe is in good contact with the battery surface or in the correct ambient location. Check for environmental factors (direct sunlight, strong drafts) that might be affecting the sensor's reading. Make sure the sensor is not damaged.
Charging parameters do not adjust with temperature
Confirm that the temperature compensation feature is enabled in the charge controller's settings and configured to use the external temperature sensor. Restart the charge controller after making setting changes.
Pros and Cons
Pros
Improves solar charge controller efficiency.
Helps extend battery lifespan.
Provides accurate battery temperature data for optimized charging.
Easy to connect to compatible controllers.
Cons
Only compatible with specific EPEver charge controllers.
Requires a compatible charge controller to function.
Additional component that adds to system complexity.
Setup, Compatibility & Care
Compatibility:
EPEver Controllers: This sensor is compatible with EPEver Tracer-AN Series and Etracer Series (e.g., Etracer-3414, Etracer-4415, Etracer-6414) MPPT solar charge controllers.
Connection: Ensure your charge controller has a dedicated temperature sensor port.
Setup:
Locate Port: Identify the temperature sensor port on your compatible EPEver charge controller. It is typically labeled 'TEMP' or similar.
Connect Sensor: Plug the TS-R sensor's connector firmly into the designated port on the charge controller.
Position Sensor: Place the temperature sensor probe in direct contact with the battery surface or in close proximity to the battery bank where it can accurately measure ambient battery temperature. Avoid placing it where it will be directly exposed to sunlight or extreme drafts that do not reflect battery temperature.
Configure Controller: Access your charge controller's settings menu via its display or connected software. Ensure the temperature compensation feature is enabled and set to use the external sensor.
Care:
Keep the sensor and its cable clean and free from dust and debris.
Inspect the cable periodically for any signs of damage.
Avoid exposing the sensor head to moisture or corrosive substances.