Spares2Go Universal Rectangular Terminal Flue Guard - Grey

SPARES2GO Universal Rectangular Terminal Flue Guard for Non-Condensing Oil Boilers. This guard is ...

Currently unavailable

Currently out of stock

This product is not available at the moment. Check back later or explore other options below.

Product Information

Full details

This guide is for owners of non-condensing oil boilers who need to protect their flue terminals. The SPARES2GO Universal Rectangular Terminal Flue Guard offers essential protection against accidental damage and complies with safety standards. Note that this guard is specifically designed for non-condensing boilers; using it with a condensing boiler will cause rapid corrosion.

All features

ColourGrey
Model Part Number04-SGZ-568
BrandSPARES2GO

Extended Product Information

FAQs

What is the primary function of the flue guard?

The flue guard protects the flue terminal from accidental damage and complies with safety standards.

What type of boilers is this guard compatible with?

This guard is designed specifically for non-condensing oil boilers.

What are the dimensions of the flue terminal this guard fits?

The guard fits flue terminals with dimensions of 11" (280mm) width, 11" (280mm) length, and 10.5" (270mm) depth.

How is the guard installed?

The guard is placed over the flue terminal and secured with four screws.

What material is used to protect against corrosion?

The guard features JS 500 automotive-grade finishing over an Electro-zinc plate and passivate surface for enhanced resistance to corrosive effects.

Where is a protective guard required according to building standards?

A protective guard is required when the flue terminal is located less than 2.1m above ground, balconies, or flat roofs accessible to people.

Why is it important to use this guard with a non-condensing boiler?

Using the guard with a condensing boiler will lead to rapid corrosion due to condensate in exhaust gases.

Troubleshooting

Guard does not fit the flue terminal.

Ensure the flue terminal dimensions match the guard's specifications (11" x 11" x 10.5").

Guard is showing signs of corrosion.

Verify that the guard is installed on a non-condensing oil boiler. If installed on a condensing boiler, replace immediately.

Difficulty securing the guard.

Ensure the screw holes align properly. You may need to pre-drill pilot holes if the terminal material is hard.

Pros and Cons

Pros

  • Protects flue terminals from damage.
  • Complies with safety regulations.
  • Resistant to corrosion from exhaust gases.
  • Easy to install.
  • Suitable for various non-condensing oil boilers.

Cons

  • Specifically designed for non-condensing boilers only.
  • Incorrect installation can lead to corrosion.
  • Requires screws for installation (not included).

Setup, Compatibility & Care

Setup:

  1. Position the guard over the flue terminal.
  2. Align the guard to ensure full coverage.
  3. Secure the guard to the terminal using four screws (screws not included).

Compatibility:

This flue guard is exclusively for non-condensing oil boiler flues. It is designed to fit terminals with dimensions of 11" x 11" x 10.5".

Care:

Inspect the guard periodically for any signs of damage or corrosion. Clean the guard with a damp cloth as needed to remove any debris or soot buildup.