Setup, Compatibility & Care
Setup: The ESR61NP is designed for installation in electrical switch boxes, either for flush mounting (plaster) or surface mounting. Ensure the power supply is disconnected before commencing any installation work.
- Wiring: Connect the supply voltage (230V AC/DC) and control voltage inputs according to the wiring diagram. Pay close attention to the non-potential-free nature of the control voltage.
- Load Connection: Connect the load to the switching contact (normally open).
- Time Setting: Adjust the release delay using the integrated potentiometer, setting it from 0 to 120 minutes.
- Function Selection: If required, configure the unit for surge current switch operation or standard switching relay function.
Compatibility: This relay is compatible with standard 230V AC mains power. It can be controlled by push-buttons or other switches providing a 230V AC or 8-230V DC signal. Ensure the connected load does not exceed the specified ratings (16A / 250V).
Care: The ESR61NP requires minimal maintenance. Keep the device clean and free from dust. Ensure adequate ventilation around the unit. No user-serviceable parts are inside; consult a qualified electrician for any repairs.