Compact 17.4mm installation relay featuring dual normally open contacts rated at 20A/250VAC. Featu...Compact 17.4mm installation relay featuring dual normally open contacts rated at 20A/250VAC. Features AgSnO2 contact material, 12VDC coil voltage, and DIN rail mounting capability. Designed for commercial HVAC, lighting, and heating applications with 5000VA AC1 rating. Includes manual test button and offers 4kV isolation between coil and contacts. This modular, DIN rail mounting 20A relay has a 12V DC coil with DPST-NO contacts.
Best current price£17.09from Rapid Online - Rapid Electronics Ltd.
The Finder DIN Rail Power Relay (model 22.22.9.012.4000) is designed for professionals in commercial HVAC, lighting, and heating systems who need a compact and reliable switching solution. Its key benefit is the high 20A switching capacity with dual normally open contacts in a space-saving 17.5mm width, DIN rail mountable design. A potential caveat is its 12VDC coil voltage, which requires a compatible DC power source.
All features
Series
22 Series
Model Part Number
22.22.9.012.4000
Brand
Finder
Extended Product Information
FAQs
What is the switching capacity of this relay?
This relay has a switching capacity of 20A at 250VAC (AC1 rating).
What type of contact configuration does this relay have?
It features a DPST-NO (Double Pole, Single Throw - Normally Open) configuration, meaning it has two independent sets of contacts that are closed when the coil is energized.
Can I mount this relay without a DIN rail?
While it is designed for 35mm DIN rail mounting, you may be able to adapt it for panel mounting with custom brackets, but this is not the intended installation method.
What is the function of the manual test button?
The manual test button allows you to manually operate the relay's contacts to check circuit continuity or test connected devices without needing to energize the 12VDC coil.
What is the isolation voltage between the coil and contacts?
The relay provides 4kV isolation between the coil and the contacts, measured at 1.2/50µs.
What is the operating temperature range?
The relay is designed to operate within a temperature range of -40°C to 40°C.
Is this relay suitable for switching inductive loads like motors?
Yes, it can switch inductive loads, but it's recommended to derate the current handling capacity compared to resistive loads. Check the AC3 ratings or consult the datasheet for specific guidance.
Troubleshooting
Relay does not energize when coil voltage is applied.
Verify the 12VDC coil voltage supply is correct and connected to the A1/A2 terminals. Check for any breaks in the control wiring. Ensure the manual test button is not held in the 'test' position.
Contacts do not close when relay is energized.
Confirm the coil is receiving the correct 12VDC. If the coil voltage is correct and the relay still does not energize, the coil may be faulty. Ensure the load connected to the contacts does not exceed the 20A rating.
Relay fails to switch high current loads reliably.
Check that the connected load does not exceed the 20A/250VAC rating. Ensure the wiring connections to the relay terminals are clean, tight, and adequately sized for the current. Verify the contact material is suitable for the load type (e.g., resistive vs. inductive).
Overheating of the relay.
Ensure the load current does not exceed the specified rating. Verify adequate ventilation within the enclosure. If the relay is constantly energized and the ambient temperature is high, consider derating the load or using a relay with a higher temperature rating.
Pros and Cons
Pros
High 20A switching capacity suitable for demanding loads.
Space-saving 17.5mm width and DIN rail mounting for efficient panel building.
Manual test button simplifies troubleshooting and verification.
Good isolation (4kV) between coil and contacts enhances safety.
Durable AgSnO2 contact material for extended life.
Cons
Requires a specific 12VDC power source for the coil.
Non-latching (monostable) design means it only stays energized while the coil is powered.
Operating temperature range is limited to -40°C to 40°C.
Cadmium-free contacts, while environmentally friendly, may have different wear characteristics than some older materials.
Setup, Compatibility & Care
Setup
Mounting: Securely attach the relay to a standard 35mm DIN rail using the integrated clip.
Wiring: Connect the control circuit to the coil terminals (typically marked A1 and A2) with the appropriate 12VDC supply. Wire the power circuit to the normally open contacts (typically marked 1 and 2 for the first pole, 3 and 4 for the second).
Verification: Use the manual test button to confirm basic circuit continuity before applying power.
Compatibility
Coil Voltage: Requires a stable 12VDC power source. Ensure your control system provides this voltage.
Load Type: Suitable for AC1 (resistive) loads up to 20A/250VAC and AC3 (inductive) loads at reduced ratings. Check specific load requirements, especially for motor control.
Environmental: Suitable for environments within -40°C to 40°C. Not rated for wet or dusty conditions (IP20 rated).
Care
Cleaning: Keep the relay clean and free from dust and debris. Use a dry or slightly damp cloth for cleaning; avoid solvents.
Ventilation: Ensure adequate airflow around the relay in the enclosure to prevent overheating, especially under continuous load.
Inspection: Periodically inspect wiring for signs of wear or damage. Check the manual test button for proper operation.