FloPlast Access Plug - 32mm

The FloPlast ABS Solvent Weld Access Plug is a versatile and robust solution designed for gaining ...

Best current price£2.33from Professional Building Supplies

All Offers

19 offers from £2.33 - £10.80

View price history by clicking the chart icon.

Professional Building SuppliesFloplast Grey Solvent Weld Waste Access Plug - 32Mm
Free delivery in 1–3 days
£2.33
Visit shop
eBayFloPlast ABS Solvent Weld Access Plug 40mm Grey
Free delivery in 1–3 days
£4.87
Visit shop
AmazonFLOPLAST Solvent Grey 40mm (43mm) Waste Access Plug
Free delivery in 1–3 days
£4.94
Visit shop
B&QB&Q - Abs Solvent Weld Access Plug 40mm Grey
Free delivery in 1–3 days
£5.31
Visit shop
The RangeFloplast Abs Solvent Weld Access Plug 32Mm Grey - Ws30 - Grey
Free delivery in 1–3 days
£5.34
Visit shop

Product Information

Full details

The FloPlast ABS Solvent Weld Access Plug is designed for plumbers and DIY enthusiasts needing reliable access to waste systems for inspection and maintenance. Its key benefit is providing a secure, permanent entry point that ensures system integrity. A potential caveat is the permanent nature of solvent weld joints, requiring careful installation. This robust ABS plug, featuring an anthracite grey finish, offers durability and UV stability, making it suitable for various pipe systems and long-term use.

All features

Model Part NumberWS30G
BrandFloPlast

Extended Product Information

FAQs

What is an access plug used for in a waste system?

An access plug, often called a cleaning eye, provides a sealed point of entry into a waste pipe system. It allows for inspection and cleaning of the pipes if blockages occur, preventing the need to dismantle large sections of the plumbing.

What does 'Solvent Weld' mean?

Solvent weld is a method of joining plastic pipes and fittings (like ABS) where a solvent cement is applied to both surfaces. The solvent temporarily dissolves the plastic, allowing the surfaces to fuse together as the solvent evaporates, creating a strong, permanent, and watertight bond.

Can I remove a solvent weld joint once it's made?

No, solvent weld joints are permanent and cannot be demounted once the joint has been made and cured. If you need to change the configuration, the connected pipe and fitting will need to be cut out and replaced.

What is the difference between 32mm, 40mm, and 50mm access plugs?

The numbers refer to the diameter of the pipe the fitting is designed to connect to. A 32mm plug is for 32mm diameter pipe, a 40mm plug is for 40mm pipe, and a 50mm plug is for 50mm pipe. You must choose the plug that matches your waste pipe's outer diameter.

Is this product suitable for outdoor use?

Yes, the FloPlast ABS Solvent Weld Access Plug features a UV-stable finish, making it resistant to degradation from sunlight and suitable for outdoor applications where it may be exposed to the elements.

What standards does this product meet?

This solvent weld waste fitting is manufactured in the UK to BS EN 1455 standards and is Kitemarked, ensuring it meets rigorous quality and safety requirements.

Do I need special tools to install this?

You will need a pipe cutter to ensure a clean, square cut on the pipe, SC250 solvent cement, and a cloth for cleaning. Ensure you are working in a well-ventilated area when using the solvent cement.

Troubleshooting

Leak at the joint after installation

This usually indicates an improper solvent weld. The joint may not have been made correctly (e.g., insufficient twist, improper solvent application) or was disturbed before fully curing. Leaks from solvent weld joints often require cutting out the faulty section and re-installing. Ensure pipes and fittings are clean and dry, and solvent cement is applied correctly during the next attempt.

Difficulty inserting pipe into the fitting

Ensure both the pipe end and the fitting socket are clean and free of obstructions. If the pipe is slightly deformed, try to gently square it off. Ensure you are using the correct size fitting for the pipe. Applying a small amount of SC250 solvent cement to both surfaces can also help lubricate the joint for easier assembly.

Solvent cement not setting properly

Check the temperature of the working environment; solvent cements perform best within a specific temperature range (typically above 5°C). Ensure the correct type of solvent cement (SC250 recommended for ABS) is being used and that it has not expired. If the joint was made in very humid conditions, this could also affect curing.

Pros and Cons

Pros

  • Durable and robust ABS material construction.
  • Secure and permanent joint via solvent welding.
  • Aesthetically pleasing anthracite grey finish.
  • UV-stable for extended longevity.
  • Manufactured to British and European standards.

Cons

  • Solvent weld joints are permanent and cannot be demounted.
  • Requires careful, precise installation to ensure a proper seal.
  • Specific solvent cement and cleaner needed for installation.
  • Requires a well-ventilated area for safe solvent cement application.

Setup, Compatibility & Care

Installation:

  1. Preparation: Ensure the outer wall of the pipe and the inner wall of the access plug fitting are clean, dry, and free from grit or swarf.
  2. Apply Solvent Cement: Apply a uniform layer of SC250 solvent cement to both the pipe end and the inside of the fitting socket.
  3. Join: Immediately push the pipe fully into the fitting. Give it a quarter-turn twist to ensure full contact and even distribution of the solvent cement.
  4. Set Time: Clean off any excess solvent with a damp cloth. Allow the joint to set for at least 5 minutes before moving.
  5. Curing: The installed joint should be left undisturbed for a minimum of 12 hours before testing the system under pressure or use.

Compatibility:

This access plug is designed for use with ABS solvent weld waste systems. It is available in 32mm, 40mm, and 50mm sizes, ensuring compatibility with standard ABS pipe diameters. Always confirm pipe size before installation.

Care:

No specific ongoing care is typically required for the access plug itself. Regular inspection of the waste system for leaks is recommended. Ensure the area around the plug remains clear for potential future access. For cleaning the plug's exterior, use a damp cloth. Avoid abrasive cleaners that could damage the finish.