Schneider Electric Spring Return Control Station Switch - XAPS11221N


Best current price£57.77from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Schneider Electric Harmony Pushbutton Box Complete - Xaps11221n
Visit shop

Best current price£57.77from Tameson UK
Shopping.co.uk recommended and popular offers
Schneider Electric Harmony Pushbutton Box Complete - Xaps11221n
Visit shop1 offer from £57.77
View price history by clicking the chart icon.
This guide is for industrial professionals seeking a reliable control station switch. The Schneider Electric XAPS11221N offers dependable operation with a spring return mechanism and a durable zinc alloy housing. A key consideration is its specific NO (Normally Open) contact configuration, which must match your system's requirements. Key features include its robust construction, IP54 protection rating, and compatibility with 22mm mounting holes.
| Series | XAP S |
|---|---|
| Model Part Number | XAPS11221N |
| Brand | Schneider Electric |
Spring Return means the switch automatically returns to its original (open) position once you release the actuator. It does not stay in the activated position.
Normally Open means the electrical circuit is broken (open) when the switch is not activated. The circuit is completed (closed) only when the switch is pressed.
The IP54 rating provides protection against dust and splashes of water, making it suitable for many outdoor industrial environments. However, it is not designed for direct exposure to heavy rain or submersion.
The housing is made of durable zinc alloy, providing robustness for industrial applications.
This switch is designed for standard 22mm diameter panel cutouts.
While rated for 600V AC and 6A, its primary application is typically within AC control circuits. Ensure your DC circuit parameters (voltage and current) are well within these limits and that the switch is suitable for DC switching if intended.
This specific model (XAPS11221N) is supplied with 2 keys.
Verify that power is supplied to the control circuit. Check wiring connections to ensure they are secure and correctly connected to the NO terminals.
The spring return mechanism may be obstructed or faulty. Inspect the mechanism for debris or damage. Ensure the switch is mounted correctly and not binding.
Check for corrosion or damage on the internal contacts. Ensure the panel cutout is clean and the switch is securely fastened to prevent vibration-induced issues.
Confirm the IP54 rating is maintained by ensuring the housing is closed properly and any gaskets or seals are intact and correctly seated.
Setup:
Compatibility:
Care: