Gas Thermocouple - 330mm - M8X1

Best current price£5.04from B&Q
Best offers
Shopping.co.uk recommended and popular offers
B&Q£5.04Visit shop B&Q - Gas Thermocouple 330mm M8X1 Suits A Variety Of Gas Appliances
Visit shop
Best current price£5.04from B&Q
Shopping.co.uk recommended and popular offers
B&Q£5.04Visit shop B&Q - Gas Thermocouple 330mm M8X1 Suits A Variety Of Gas Appliances
Visit shop2 offers from £5.04 - £6.05
View price history by clicking the chart icon.
The Under Control Instruments 330mm Gas Thermocouple with an M8X1 connection is an essential safety component designed for professional gas appliance maintenance, particularly for Archway kebab burners, hot water boilers, and general gas heating systems. It serves as a reliable replacement part to ensure the pilot light flame is accurately detected, preventing gas leaks by shutting off the supply if the flame is extinguished. While it offers broad compatibility with many industrial burners, users must ensure the 330mm length is sufficient for their specific appliance configuration before installation.
| Model Part Number | 330mm M8x1 |
|---|---|
| Brand | Uci |
It is compatible with systems requiring an M8X1 connection and a 330mm reach, commonly found on Archway burners and boilers.
No, you should never cut or modify a thermocouple, as this will destroy its ability to generate the necessary electrical current.
Typically, an adjustable wrench or small spanner is all that is needed to secure the M8X1 nuts.
It is designed to work with standard pilot assemblies that accept M8X1 threaded thermocouples.
If the appliance gas valve closes immediately after you release the knob or button, the thermocouple is likely failing to generate a signal.
Check that the thermocouple tip is fully immersed in the pilot flame and that the M8X1 connection at the valve is tightened properly.
Clean the thermocouple tip of any carbon deposits and ensure there is no corrosion on the connection point.
Verify that your appliance requires an M8X1 connection; if the thread size is different, the part is incompatible.
Installation should only be performed by a competent gas technician. To install, ensure the gas supply is isolated at the main valve. Remove the old thermocouple by unscrewing the M8X1 nut from the gas valve and the retention bracket on the pilot assembly. Thread the new 330mm thermocouple into the gas valve, taking care not to overtighten, as this can damage the brass threads. Ensure the tip is positioned securely in the pilot flame path. For care, keep the tip free from heavy carbon build-up or grease, as these can insulate the sensor and cause intermittent flame failures.