WAGO 750-455 - Analog Input Module





Best current price£24.48from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Wago Fieldbus Decentralized Peripheral - Power Supply/Segment Module - 750-602
Visit shop




Best current price£24.48from Tameson UK
Shopping.co.uk recommended and popular offers
Wago Fieldbus Decentralized Peripheral - Power Supply/Segment Module - 750-602
Visit shop11 offers from £24.48 - £624.77
View price history by clicking the chart icon.
10 offers from £6.54 - £180.50
View price history by clicking the chart icon.
This WAGO 750-455 module is designed for industrial automation applications requiring precise measurement of 4-20 mA current signals. It offers reliable data acquisition with its 12-bit resolution and 4 independent input channels, making it suitable for process control and monitoring systems. A key benefit is its robust design and electrical isolation, ensuring system integrity. However, users must ensure compatibility with their existing fieldbus system.
| Brand | WAGO |
|---|
The WAGO 750-455 module is specifically designed to process 4-20 mA current signals.
This module features four independent analog input channels.
The module offers a resolution of 12 bits for its analog inputs.
The module requires a supply voltage of 24V DC.
Yes, the module provides 0.5 kV of electrical isolation.
The module has dimensions of 12 mm (width) x 100 mm (depth) x 69.8 mm (height).
No, the WAGO 750-455 is designed exclusively for current input signals (4-20 mA).
Verify the 24V DC power supply is connected and active. Check that the 4-20 mA sensors are correctly wired to the input terminals and are functioning properly. Ensure the fieldbus connection to the PLC is established and the module is recognized by the system.
Confirm that the sensor's output range matches the module's 4-20 mA input. Check for any potential electrical interference on the signal lines. Ensure the module's resolution (12-bit) is sufficient for the required measurement precision. Verify the PLC scaling is set correctly.
Ensure the fieldbus system is properly configured. Check all connections between the fieldbus coupler/controller and the 750-455 module. Consult the fieldbus system's manual for specific integration steps.
Ensure proper ventilation around the module within the control cabinet. Avoid installing the module in direct sunlight or near significant heat sources. Check if the ambient temperature exceeds the operational limits.
Setup:
Compatibility:
Care: