For DIN rail mounting with low switching noise and zero-voltage switching. Features control with 2...For DIN rail mounting with low switching noise and zero-voltage switching. Features control with 230V and an additional control input of 8-230V/UC (galvanically separated). Offers a time setting for fall-back delay from 2 to 120 minutes. Glow lamp current is a maximum of 150 mA. The device switches off when power fails. Functions can be selected with a rotary switch: Surge-current switch, Switching relay, or Surge-current switch with fall-back delay (allowing for switch-off pre-warning and scanner light attachment). Rated switch current is 16A with a supply voltage of 230V AC/DC. Maximum incandescent lamp load is 2300W.
Best current price£52.15from Rapid Online - Rapid Electronics Ltd.
The Eltako ESR12NP-230V+UC is a versatile impulse switch designed for DIN rail mounting, ideal for home automation and control systems requiring reliable switching. Its key benefit is the hybrid technology offering low switching noise and extended contact life, along with flexible control options. A potential caveat is the 150 mA maximum glow lamp current limitation on the 230V control input.
All features
Series
ESR12NP
Model Part Number
21100102
Brand
Eltako
Extended Product Information
FAQs
What is the main advantage of zero-passage switching?
Zero-passage switching reduces electrical stress on the relay contacts and the connected load (like lamps) by switching them on or off only when the AC voltage waveform crosses zero. This significantly extends the lifespan of both the relay and the connected devices, especially energy-saving lamps.
Can I control this relay with different voltages?
Yes, the ESR12NP-230V+UC has a primary 230V AC control input and an additional, electrically isolated universal voltage (UC) input that accepts voltages from 8V to 230V AC/DC. This provides significant flexibility in how you connect and control the relay.
What does the fall-back delay function do?
The fall-back delay function allows you to set a timer (from 2 to 120 minutes) after which the relay will switch off. This is useful for applications like stairwell lighting, where lights are turned on for a specific duration before automatically switching off. It can also provide a switch-off pre-warning.
What is the maximum load this relay can handle?
The relay is rated for a maximum switching current of 16A at 250V AC. For incandescent lamps, it can handle up to 2300W. Always ensure your connected load does not exceed these ratings.
How do I select the operating mode?
Operating modes (Surge-current switch, Switching relay, Surge-current switch with fall-back delay) are selected using the rotary switch located on the front of the device.
Is this relay suitable for noisy environments?
Yes, the ESR12NP-230V+UC features very low switching noise due to its hybrid technology and zero-passage switching, making it suitable for quiet environments where audible clicks are undesirable.
What is the 'glow lamp current' specification?
The glow lamp current refers to the minimum current required to keep certain types of lamps (like older fluorescent starters or some LED drivers) 'awake' or ready to ignite. The ESR12NP-230V+UC can handle up to 150mA for this purpose on its 230V control input.
Troubleshooting
Relay does not switch on.
Verify that the supply voltage is correctly connected and within the specified range (230V AC/DC). Check that the control input signal is present and at the correct voltage level (8-230V UC or 230V AC).
Relay switches off immediately or does not hold.
Ensure the correct function is selected via the rotary switch. If using the fall-back delay, confirm the time setting is appropriate. Check that the control signal is continuous if a sustained state is required (unless using impulse mode).
LED indicators are not working.
Check the supply voltage connection. If the LEDs indicate a blocked pushbutton (blinking), ensure the pushbutton is not stuck or shorted, especially when the ER function is not set.
Device switches on/off erratically.
Check for voltage fluctuations in the supply or control circuits. Ensure control wiring is properly shielded if in a noisy electrical environment. Verify that the selected function (e.g., impulse vs. sustained control) matches the intended operation.
Overheating during operation.
Ensure the connected load does not exceed the rated switching current (16A) or power (2300W incandescent). Check for adequate ventilation around the module. Verify wiring connections are tight to prevent resistance heating.
Pros and Cons
Pros
Enhanced contact and lamp longevity due to zero-passage switching.
Flexible control options with standard 230V and universal UC input.
Adjustable time delay adds valuable functionality for timed operations.
Quiet operation with very low switching noise.
Clear visual indication of relay status.
Cons
Limited glow lamp current (150 mA) on the 230V control input.
Requires DIN rail mounting, not suitable for surface mounting.
Primarily designed for AC loads, specific DC load handling may vary.
Setup, Compatibility & Care
Setup:
Mounting: Install the ESR12NP-230V+UC module onto a standard DIN rail (TH35) within your electrical enclosure.
Wiring: Connect the supply voltage (230V AC/DC) to the designated terminals. Wire the control signal(s) to the appropriate control input terminals (230V or 8-230V UC).
Load Connection: Connect your load (e.g., lights, motors) to the normally open (NO) contact and the neutral or switched line, respecting the maximum switching current and voltage ratings.
Function Selection: Use the rotary switch to select the desired operating mode: Surge-current switch, Switching relay, or Surge-current switch with fall-back delay.
Time Setting (if applicable): For the fall-back delay function, set the desired time using the minute scale on the rotary switch (2-120 minutes).
Compatibility:
Supply Voltage: Compatible with 230V AC/DC power supplies.
Control Voltage: Accepts control signals from 8V to 230V AC/DC (UC), providing flexibility.
Load Types: Suitable for resistive loads up to 2300W (e.g., incandescent lamps) and general loads up to 16A/250V AC. Best performance with loads that benefit from zero-crossing switching.
Mounting: Exclusively designed for DIN rail mounting (1 module width).
Care:
Cleaning: Disconnect power before cleaning. Wipe the exterior with a dry or slightly damp cloth. Avoid using solvents or abrasive cleaners.
Ventilation: Ensure adequate ventilation around the module within the enclosure. Do not cover ventilation slots.
Maintenance: No user-serviceable parts inside. The hybrid technology and zero-passage switching minimize the need for periodic maintenance.